FDA Adverse Event Injury Summary report: N

JOSTENT GRAFTMASTER

MDR report key: 3071414 · Received April 22, 2013

Report

Report Number
2024168-2013-02480
Event Type
Injury
Date Received
April 22, 2013
Date of Event
February 8, 2012
Report Date
April 3, 2013
Manufacturer
AV-TEMECULA-CT
Product Code
MAF
PMA / PMN Number
H000001
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

(B)(4). RESULTS: DB DEPLOYMENT AND COVERED STENT PLACEMENT WERE TECHNICALLY SUCCESSFUL IN ALL PATIENTS, EXCEPT ONE PATIENT IN GROUP B IN WHOM THE COVERED STENT FAILED TO NAVIGATE TO THE TARGET DCCF. NO SIGNIFICANT DIFFERENCES WERE SEEN BETWEEN THE TWO GROUPS IN TECHNICAL SUCCESS, MORTALITY, MORBIDITY OR FINAL CLINICAL OUTCOMES. IN THIS NONRANDOMIZED, PROSPECTIVE STUDY OF POSTTRAUMATIC DCCF TREATMENT, THE 12-MONTH ANGIOGRAPHIC RESULTS OF TREATMENT WITH COVERED STENTS WAS SUPERIOR. IT WAS REPORTED THAT BETWEEN (B)(6) 2007 AND (B)(6) 2011, 15 PATIENTS (9 MALE) UNDERWENT TREATMENT FOR AN EXISTING POSTTRAUMATIC DIRECT CAROTID-CAVERNOUS FISTULA (DCCF) OF THE INTERNAL CAROTID ARTERY, USING AN UNSPECIFIED JOSTENT GRAFTMASTER COVERED STENT. AFTER THE 12-MONTH STUDY PERIOD, AN UNSPECIFIED NUMBER OF PATIENTS WITH RESIDUAL OR RECURRENT CAROTID-CAVERNOUS FISTULAS OR PSEUDOANEURYSMS WERE TREATED WITH DETACHABLE BALLOON, COILING, OR COVERED STENTS. NO ADDITIONAL INFORMATION WAS NOTED. GUIDE WIRE: BOSTON SCIENTIFIC TRANSCEND FLOPPY. GUIDE CATHETER: 6-FRENCH CORDIS ENVOY. (B)(4) - INCORRECT ANATOMY. ARTICLE: COMPARISON OF COVERED STENTS WITH DETACHABLE BALLOONS FOR TREATMENT OF POSTTRAUMATIC CAROTID-CAVERNOUS FISTULAS", BO YIN, HAN-SONG SHENG, RUI-LI WEI, JIAN LIN, HUI ZHOU, NU ZHANG. (JOURNAL OF CLINICAL NEUROSCIENCE(0967-5868) 2013 20(3):367-372). IT IS INDICATED THAT THE DEVICE IS NOT RETURNING FOR EVALUATION; THEREFORE A FAILURE ANALYSIS OF THE COMPLAINT DEVICE COULD NOT BE COMPLETED. A REVIEW OF THE LOT HISTORY RECORD AND COMPLAINT HISTORY OF THE REPORTED LOT COULD NOT BE CONDUCTED, BECAUSE THE LOT NUMBER WAS NOT PROVIDED. IT SHOULD BE NOTED THAT THE RX GRAFTMASTER INSTRUCTIONS FOR USE (IFU) STATES THAT THE JOSTENT GRAFTMASTER IS A BALLOON-EXPANDABLE PRE-MOUNTED CORONARY STENT GRAFT FOR INTRALUMINAL CHRONIC PLACEMENT IN CORONARY ARTERIES OR AORTO-CORONARY BYPASS GRAFTS FOR THE TREATMENT OF: CORONARY ARTERY ANEURYSM, CORONARY BYPASS-VEIN GRAFT ANEURYSM, ACUTE CORONARY ARTERY PERFORATION AND ACUTE CORONARY ARTERY RUPTURE. BASED ON THE INFORMATION REVIEWED, THERE IS NO EVIDENCE TO INDICATE THE PRESENCE OF A PRODUCT DEFICIENCY.

Description of Event or Problem · 1

THIS EVENT WAS CAPTURED BASED ON REVIEW OF THE FOLLOWING ARTICLE: "COMPARISON OF COVERED STENTS WITH DETACHABLE BALLOONS FOR TREATMENT OF POSTTRAUMATIC CAROTID-CAVERNOUS FISTULAS", BO YIN, HAN-SONG SHENG, RUI-LI WEI, JIAN LIN, HUI ZHOU, NU ZHANG. (JOURNAL OF CLINICAL NEUROSCIENCE(0967-5868) 2013 20(3):367-372). BACKGROUND: TREATMENT OF POSTTRAUMATIC DIRECT CAROTID-CAVERNOUS FISTULA (DCCF) WITH DETACHABLE BALLOONS (DB) IS ASSOCIATED WITH RELATIVELY LOW COMPLETE OCCLUSION RATES (COMPLETE SEALING OF FISTULA WITH NO RESIDUAL CAVITY AND NO ENDOLEAKS). THIS STUDY AIMS TO COMPARE THE ANGIOGRAPHIC AND CLINICAL RESULTS OF TREATMENT WITH COVERED STENTS WITH THE RESULTS OF TREATMENT WITH DB. METHOD: THIRTY-FOUR PATIENTS WITH POSTTRAUMATIC DCCF WERE SELECTED FOR TREATMENT WITH NON-ABBOTT DB (N = 19, GROUP A) OR JOSTENT GRAFTMASTER COVERED STENTS (N = 15, GROUP B). DATA ON THE TECHNICAL SUCCESS, DURATION OF INITIAL PROCEDURE AND HOSPITAL STAY, INITIAL AND FINAL ANGIOGRAPHIC RESULTS, MORTALITY, MORBIDITY AND FINAL CLINICAL OUTCOMES WERE COLLECTED AND ANALYZED WITHIN 12 MONTHS, WITH POST-PROCEDURAL FOLLOW-UPS PERFORMED AT 1, 3, 6, AND 12 MONTHS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
171457 JOSTENT GRAFTMASTER CORONARY STENT GRAFT MAF AV-TEMECULA-CT

Patients

Seq Age Sex Outcome Treatment
1 33 YR Hospitalization| R CONCOMITANT MEDICAL DEVICES