FDA Adverse Event Malfunction Summary report: N

DRIVER FOR DETACHABLE TEMPORARY FIXATION PIN

MDR report key: 3062473 · Received April 16, 2013

Report

Report Number
1719045-2013-10694
Event Type
Malfunction
Date Received
April 16, 2013
Date of Event
December 7, 2011
Report Date
December 7, 2011
Manufacturer
SYNTHES MONUMENT
Product Code
LXH
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CO, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. A REVIEW OF THE DEVICE HISTORY RECORDS WAS PERFORMED AND NO COMPLAINT RELATED ISSUES WERE FOUND. THE DEVICE WAS RETURNED FOR A MANUFACTURING EVALUATION AND WAS MANUFACTURED BY BEERE PRECISION (PRESENTLY TELEFLEX MEDICAL). DUE TO AN UNKNOWN CAUSE, ONE OF THE FLANGES ON THE TIP OF THE DRIVER WAS BROKEN OFF AND ANOTHER FLANGE WAS SLIGHTLY BENT. THE PART EXHIBITED MINOR SCRATCHES NEAR THE TIP AND ALONG THE SHAFT. THE EVALUATION INDICATED THAT THE REPORTED FAILURE IS NOT ASSOCIATED WITH THE MANUFACTURING PROCESSES AT TELEFLEX MEDICAL. THEREFORE, BASED ON THE EVALUATION AND THE UNKNOWN ROOT CAUSE, THIS COMPLAINT IS DEEMED INDETERMINATE FROM A MANUFACTURING STANDPOINT. A PRODUCT DEVELOPMENT EVALUATION WAS ALSO PERFORMED. ONE OF THE SIX FLANGES ON THE TIP OF THE DRIVER THAT SPLAYS TO RETAIN THE DETACHABLE TEMP FIXATION PIN WAS MISSING. IT APPEARED TO HAVE FRACTURED AT THE SMALLEST CROSS SECTION BETWEEN THE HOLES IN THE SLOTTED CUTS THAT FORM THE FLANGES. BASED ON THE REMAINING MATERIAL AT THE FRACTURE SITE, IT APPEARED TO HAVE BEEN BENT OUT AND AWAY FROM THE DRIVER AXIS AT THE TIME OF FRACTURE. AN ADJACENT FLANGE WAS PLASTICALLY DEFORMED AND SLIGHTLY BENT OUT AND AWAY FROM THE DRIVER AXIS AS WELL. THE REMAINDER OF THE INSTRUMENT HAD MINOR SCRATCHES ALONG THE SHAFT AND AT THE METAL END OF THE HANDLE. THE DESIGN OF THE TEMPORARY FIXATION PIN DRIVER FOR THE ANTERIOR TENSION BAND SYSTEM WAS EVALUATED AND FOUND TO BE APPROPRIATE FOR ITS INTENDED APPLICATION. THE FLANGES ON THE TIP OF THE TEMP FIXATION PIN DRIVER ARE INTENDED TO SPLAY OVER THE DETACHABLE TEMPORARY FIXATION PIN HEAD AND RETAIN IT ON THE DRIVER ONCE THE HEX DRIVE IS ENGAGED. PROPER ENGAGEMENT AND SPLAYING OF THE FLANGES OCCURS WHEN THE AXES OF THE TEMP FIXATION PIN AND DRIVER ARE ALIGNED WHEN BEING ASSEMBLED. PLASTIC DEFORMATION OR FAILURE OF THE FLANGES MAY OCCUR IF EXCESSIVE FORCES ARE APPLIED OFF THE DRIVER AXIS. TWO TEMPORARY FIXATION PIN DRIVERS ARE ALSO PROVIDED IN THE SET. THE FRACTURE OF THE DRIVER TIP FLANGES WAS MOST LIKELY A RESULT OF MISUSE, CAUSING EXCESSIVE OFF-AXIS LOADING TO THE INSTRUMENT. HOWEVER, NOT ENOUGH INFORMATION WAS PROVIDED IN THE COMPLAINT TO DETERMINE THAT THIS IS THE EXACT ROOT CAUSE. THEREFORE, THIS COMPLAINT IS DEEMED INDETERMINATE FROM A DESIGN STANDPOINT.

Additional Manufacturer Narrative · 1

SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. BLANK FIELDS ON THIS FORM INDICATE THE INFORMATION IS UNKNOWN, UNAVAILABLE OR UNCHANGED. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR.(B)(4)

Description of Event or Problem · 1

IT WAS REPORTED THAT DURING AN ANTERIOR LUMBAR INTERBODY FUSION PROCEDURE AT LEVELS L5-S1, ONE OF THE FLANGES ON THE PIN HOLDER THAT HOLDS THE TIP OF THE PIN BROKE OFF. IT DID NOT BREAK INTO THE WOUND AND THERE WAS NOTHING TO RETRIEVE. THE SURGEON USED ANOTHER PIN HOLDER TO COMPLETE THE PROCEDURE. THIS REPORT IS FOR FILE (B)(4).

Description of Event or Problem · 1

THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
162151 DRIVER FOR DETACHABLE TEMPORARY FIXATION PIN LXH SYNTHES MONUMENT 559463M05

Patients

Seq Age Sex Outcome Treatment
1