FDA Adverse Event
Malfunction
Summary report: N
POWERED WHEELCHAIR
MDR report key: 3051673
·
Received April 10, 2013
Report
- Report Number
- 1525712-2013-02726
- Event Type
- Malfunction
- Date Received
- April 10, 2013
- Report Date
- March 13, 2013
- Manufacturer
- INVACARE TAYLOR STREET
- Product Code
- ITI
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- MEDICAL EQUIPMENT COMPANY TECHNICIAN/REPRESENTATIVE
Narratives
Additional Manufacturer Narrative · 1
(B)(4) HAS BEEN INITIATED FOR THIS ISSUE. THE MALFUNCTION HAS NOT BEEN CONFIRMED.
Description of Event or Problem · 1
PROVIDER STATES END USER WAS DRIVING AND WENT OVER A THRESHOLD THE WELD ON THE WALKING BEAM BROKE, AND ALSO EFFECTED THE CYLINDER.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 153675 | POWERED WHEELCHAIR | 890.3860 | ITI | INVACARE TAYLOR STREET | TDXSIV-2 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|