FDA Adverse Event Malfunction Summary report: N

HOMEPUMP ECLIPSE: 400 ML, 100 ML/HR

MDR report key: 3043051 · Received March 7, 2013

Report

Report Number
2026095-2013-00041
Event Type
Malfunction
Date Received
March 7, 2013
Date of Event
January 1, 2013
Report Date
February 5, 2013
Manufacturer
I-FLOW CORP.
Product Code
MEB
PMA / PMN Number
K052117
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IL, US
Reporter Occupation
NOT APPLICABLE

Narratives

Additional Manufacturer Narrative · 1

METHOD: THE SAMPLE WILL NOT BE RETURNED FOR EVAL AND INVESTIGATION. RESULTS: A REVIEW OF THE DEVICE HISTORY RECORD (DHR) WAS CONDUCTED FOR THE LOT NUMBER PROVIDED, AND THE DEVICE PASSED ALL MFG SPECIFICATIONS PRIOR TO RELEASE. CONCLUSIONS: THE DEVICE IS UNAVAILABLE TO EVALUATE AND INVESTIGATE; THEREFORE I-FLOW IS UNABLE TO DETERMINE A CONCLUSION THAT THE DEVICE IN QUESTION PERFORMED AS INTENDED AS THIS DEVICE WAS TESTED BY THE END USER. I-FLOW WAS NOT PROVIDED WITH THE TESTING RESULTS OR INFO ON HOW THE DEVICE WAS TESTED, AS WELL AS HOW THE CONCLUSION OF FAST FLOW WAS DRAWN BASED ON THEIR TESTING RESULTS. ALTHOUGH AN INVESTIGATION FOR THIS INCIDENT COULD NOT BE PERFORMED, I-FLOW IS CONDUCTING FURTHER INVESTIGATIONS INTO THE DEFECT TYPE ¿FAST FLOW¿ FOR CONFIRMED AND UNCONFIRMED. INFO FROM THIS INCIDENT HAS BEEN INCLUDED IN OUR PRODUCT COMPLAINT AND MDR TREND REPORTING SYSTEM. I-FLOW PROVIDES A ¿CAUTIONS¿ IN ITS DFU WHICH STATES THE FOLLOWING: ACTUAL INFUSION TIMES MAY VARY DUE TO THE FOLLOWING: FILLING THE PUMP LESS THAN NOMINAL RESULTS IN FASTER FLOW RATE. FILLING THE PUMP MORE THAN NOMINAL RESULTS IN SLOWER FLOW RATE. TEMPERATURE WILL AFFECT SOLUTION VISCOSITY, RESULTING IN SHORTER OR LONGER DELIVERY TIME. THE HOMEPUMP ECLIPSE IS DESIGNED TO BE USED AT ROOM TEMP (20 DEGREES CELSIUS/ 68 DEGREES FAHRENHEIT). (B)(4). THE HOMEPUMP ECLIPSE AND TUBING SHOULD BE WORN OUTSIDE THE CLOTHING. THE HOMEPUMP ECLIPSE MUST BE FILLED 4 HOURS PRIOR TO ADMINISTRATION TO INFUSE AT THE LABELED FLOW RATE. IF THE HOMEPUMP ECLIPSE IS USED IMMEDIATELY AFTER FILLING, FLOW RATE MAY INCREASE BY UP TO 50%.

Description of Event or Problem · 1

DRUG/DILUENT: SODIUM CHLORIDE 0.9%. FILL VOLUME: 400 ML. FLOW RATE: 100 ML/HR. PROCEDURE: N/A ¿ TEST PUMP. CATHPLACE: N/A. (REFERENCE 2026095-2013-00039/13-00185, 2026095-2013-00040/13-00184, AND 2026095-2013-00041/13-00187). THERE WAS NO PATIENT CONTACT, CUSTOMER REPORTED PUMP INFUSED AN HOUR EARLIER THAN IT WAS SUPPOSED TO. THIS REPORTED PUMP WAS A TEST PUMP. IT WAS TESTED BY THE END USER AT THEIR FACILITY DUE TO A PT COMPLAINT OF FAST FLOW FOR REFERENCE NUMBER: 2026095-2013-00185.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
98466 HOMEPUMP ECLIPSE: 400 ML, 100 ML/HR ELASTOMERIC PUMP MEB I-FLOW CORP. E401000 0200608305

Patients

Seq Age Sex Outcome Treatment
1 NA