EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM
Report
- Report Number
- 2024168-2013-01866
- Event Type
- Injury
- Date Received
- April 1, 2013
- Date of Event
- September 24, 2012
- Report Date
- March 7, 2013
- Manufacturer
- AV-TEMECULA-CT
- Product Code
- NTE
- PMA / PMN Number
- K090665
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- PA, US
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
(B)(4). DURING PROCESSING OF THIS COMPLAINT, ATTEMPTS WERE MADE TO OBTAIN COMPLETE EVENT, PATIENT AND DEVICE INFORMATION. ESTIMATED DATE. ARTICLE - OPTICAL COHERENCE TOMOGRAPHY IMAGING IN ASYMPTOMATIC PATIENTS WITH CAROTID ARTERY STENOSIS. THERE WAS NO REPORTED PRODUCT DEFICIENCY. THE REPORTED PATIENT EFFECTS OF EMBOLISM AND TRANSIENT ISCHEMIC ATTACK (TIA) ARE KNOWN OBSERVED AND POTENTIAL ADVERSE EVENTS AS LISTED IN THE EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM ELECTRONIC INSTRUCTIONS FOR USE. ALTHOUGH A CONCLUSIVE CAUSE FOR THE REPORTED PATIENT EFFECTS, AND THE RELATIONSHIP TO THE PRODUCT, IF ANY, CANNOT BE DETERMINED, THERE IS NO INDICATION OF A PRODUCT QUALITY DEFICIENCY WITH RESPECT TO MANUFACTURING, DESIGN OR LABELING.
THE FOLLOWING EVENTS WERE NOTED THROUGH A PERIODIC ARTICLE REVIEW: MEHMET CILINGIROGLU, ABDUL HAKEEM, MARC FELDMAN, MARK WHOLEY.(CARDIOVASCULAR REVASCULARIZATION MEDICINE 14 (2013) 53-56): OPTICAL COHERENCE TOMOGRAPHY IMAGING IN ASYMPTOMATIC PATIENTS WITH CAROTID ARTERY STENOSIS. INTRAVASCULAR OPTICAL COHERENCE TOMOGRAPHY (IVOCT) RECENTLY EMERGED AS A NOVEL IMAGING MODALITY WITH A UNIQUE RESOLUTION TO IDENTIFY VULNERABLE PLAQUE CHARACTERISTICS. IN ONE CASE, DURING THE PROCEDURE IN THE LEFT INTERNAL CAROTID ARTERY FOR TREATMENT OF HIGH GRADE STENOSIS AND INTRALUMINAL THROMBOSIS, A 6MM EMBOSHIELD NAV 6 EMBOLIC PROTECTION FILTER WAS PLACED. ANGIOPLASTY AND STENTING WERE PERFORMED. FOLLOWING POST-DILATATION USING AN UNSPECIFIED 5X20 BALLOON, THE PATIENT DEVELOPED A TRANSIENT EPISODE OF WORD SEARCHING THAT RESOLVED FOLLOWING REMOVAL OF THE EMBOSHIELD FILTER. UPON REMOVAL OF THE FILTER, A TINY EMBOLIC FRAGMENT WAS NOTED AT THE FILTER TIP. THE PATIENT REMAINED IN THE HOSPITAL FOR ONE DAY WITH NORMAL NEUROLOGICAL FINDINGS AND WAS DISCHARGED HOME.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 133300 | EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM | EMBOLIC PROTECTION SYSTEM | NTE | AV-TEMECULA-CT |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 83 YR | Other |