4.5MM HEX ADJ SCREWDRIVER BLADE W/SPADE POINT HXC
Report
- Report Number
- 1719045-2013-10407
- Event Type
- Malfunction
- Date Received
- March 26, 2013
- Report Date
- July 29, 2011
- Manufacturer
- SYNTHES MONUMENT
- Product Code
- HXX
- PMA / PMN Number
- EXEMPT
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- WI, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. THE DHR WAS REVIEWED AND NO ISSUES THAT WOULD HAVE RESULTED IN THIS COMPLAINT WERE FOUND. THE SUPPLIER'S CERTIFICATIONS INDICATE THE CORRECT MATERIAL WAS USED AND CORRECT HARDNESS VALUES WERE OBTAINED. THE DEVICE WAS RETURNED WITH ALL THE COMPONENTS, HOWEVER THE DEVICE WAS DISASSEMBLED AND EVALUATIONS WERE REQUESTED OF THE SUBCOMPONENTS. THIS EVALUATION IS ON THE OUTER SLEEVE ONLY, AND NOT THE BROKEN SCREWDRIVER. THE OUTER SLEEVE DOES NOT SHOW ANY VISUAL ANOMALIES. THE MEASURABLE DIMENSIONS ARE WITHIN PRINT SPECIFICATION. THIS COMPLAINT IS INVALID FROM A MANUFACTURING STANDPOINT.
SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. THE PRODUCT EVALUATION INVESTIGATION DETERMINED THE FOLLOWING: IT CAN BE INFERRED FROM THE AXIAL OUT-OF-PLANE BENDING OF THE SCREWDRIVER BLADES (351.035) THAT RADIAL FORCES (PERPENDICULAR TO THE CENTERLINE AXIS) WERE APPLIED TO THE SCREWDRIVER BLADES CAUSING THE BENDING OBSERVED. THE RADIAL FORCES WOULD MOST LIKELY HAVE BEEN APPLIED AT THE TIP OF THE SCREWDRIVER BLADE INDUCING INCREASED STRESS ON THE TIP. AN INCREASED STRESS IN THE TIP REGION WOULD REDUCE THE FATIGUE LIFE AND COULD LEAD TO BREAKAGE WITHIN THE REGION OF THE SMALLEST CROSS-SECTIONAL AREA (THE WEAKEST REGION) OVER REPEATED USE OF THE SIMILAR MANNER. NO DETAILS HAVE BEEN PROVIDED OF THE PROCEDURE AND CONDITIONS SURROUNDING THE TIP BREAKAGE. THEREFORE FROM A DESIGN PERSPECTIVE THE COMPLAINT IS INDETERMINATE BECAUSE OF THE LACK OF INFORMATION. TIP BREAKAGE IS COVERAGE IN THE RISK ASSESSMENT. ORIGINAL AWARENESS DATE IS 07/29/2011.
IT WAS REPORTED THAT THE TIPS HAD BROKEN OFF OF TWO 4.5MM HEX ADJUSTABLE SCREWDRIVERS. THE HOSPITAL DISCARDED THE BROKEN TIPS. THIS IS 4 OF 4 REPORTS FOR THIS EVENT.
THIS IS REPORT 4 OF 4 FOR THIS COMPLAINT (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 122952 | 4.5MM HEX ADJ SCREWDRIVER BLADE W/SPADE POINT HXC | HXX | SYNTHES MONUMENT | 011647 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |