FDA Adverse Event Injury Summary report: N

3.7MM TI CERVICAL SPINE SCREW SLF-TPNG/VARIABLE ANGLE 14MM

MDR report key: 3020667 · Received March 26, 2013

Report

Report Number
8030965-2013-10630
Event Type
Injury
Date Received
March 26, 2013
Date of Event
April 19, 2012
Report Date
April 19, 2012
Manufacturer
SYNTHES GMBH
Product Code
OVE
PMA / PMN Number
K112068
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
OH
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. ORIGINAL AWARENESS DATE IS (B)(4) 2012. PLACEHOLDER.

Additional Manufacturer Narrative · 1

ADDITIONAL NARRATIVE: SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. BLANK FIELDS ON THIS FORM INDICATE THE INFORMATION IS UNKNOWN, UNAVAILABLE OR UNCHANGED. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN AS NO DEVICE WAS RETURNED AND NO LOT NUMBER WAS PROVIDED.

Description of Event or Problem · 1

THIS IS REPORT 3 OF 3 FOR THIS COMPLAINT (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED THAT DURING A ZERO-P IMPLANTATION AT C6-7 SURGEON INSERTED THE IMPLANT, LOT 7755852 AND THE LOCKING MECHANISM WOULD NOT LOCK. SURGEON USED THE SCREW REMOVAL TOOL TO REMOVE THE IMPLANT, SURGEON THEN FLIPPED THE IMPLANT RE-INSERTED AND THE LOCKING MECHANISM WOULD NOT LOCK. THE SURGEON SELECTED ANOTHER IMPLANT LOT 3537843. AT THE INSERTION OF THE SECOND SCREW, THE SCREW AND PLATE SEPARATED FROM THE PEEK. SURGEON REMOVED THE ZERO-P IMPLANT BY HAND AND SELECTED ANOTHER LARGER ZERO-P IMPLANT. THE PROCEDURE WAS COMPLETED WITH NO FURTHER COMPLICATIONS. THE PROCEDURE WAS EXTENDED ABOUT 20 MINUTES WITH NO REPORT OF PATIENT DISTRESS. DURING THE REMOVAL OF THE SCREW, THE INNER SHAFT OF THE INNER SHAFT FOR REMOVAL SCREWDRIVER BENT, AND ONE 3.7MM TI CERVICAL SPINE SCREW WAS DAMAGED. THIS IS REPORT 3 OF 3 FOR THIS EVENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
124378 3.7MM TI CERVICAL SPINE SCREW SLF-TPNG/VARIABLE ANGLE 14MM OVE SYNTHES GMBH

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention