FDA Adverse Event Malfunction Summary report: N

MATRIX SIMPLE PERSUADER-LONG

MDR report key: 3002484 · Received March 13, 2013

Report

Report Number
8030965-2013-10493
Event Type
Malfunction
Date Received
March 13, 2013
Date of Event
February 7, 2012
Report Date
February 7, 2012
Manufacturer
SYNTHES MONUMENT
Product Code
LXH
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. A REVIEW OF THE DEVICE HISTORY RECORDS WAS PERFORMED AND NO COMPLAINT RELATED ISSUES WERE FOUND. THE PRODUCT DEVELOPMENT EVALUATION SHOWED THREADED PERSUADER (03.632.008), STANDARD SIMPLE PERSUADER (03.632.009) AND LONG SIMPLE PERSUADER (03.632.079) WERE RETURNED. BOTH STANDARD SIMPLE PERSUADERS AND 1 LONG SIMPLE PERSUADER WERE RETURNED ALSO. ONE OF THE LONG PERSUADERS WAS NOT RETURNED. ONE OF THE THREADED PERSUADERS WAS NOT RETURNED AND ONLY THE REDUCTION TUBE WAS RETURNED FOR THE OTHER. THE PART OF THAT DEVICE THAT WOULD NEED TO BE EVALUATED, REDUCTION INSERT, BASED ON THE REPORTED CONDITION WAS NOT RETURNED FOR EITHER OF THEM. THEREFORE, THE EVALUATION WAS NOT POSSIBLE FOR THE 2 THREADED PERSUADERS AND 1 LONG SIMPLE PERSUADER. OF THE 3 SIMPLE PERSUADERS THAT WERE RETURNED, ALL THREE OF THE DEVICE FUNCTION AS INTENDED. THEY OPEN AND CLOSE EASILY AND RELEASE AND SPRING BACK INTO POSITION AS INTENDED WHEN THE RELEASE BUTTON IS PRESSED. EACH WAS TRIED 10 TIMES AND THEY SPRUNG BACK INTO POSITION WHEN THE RELEASE BUTTON WAS PRESSED. THE RETURNED DEVICES FUNCTION AS INTENDED AND THE COMPLAINT CONDITION COULD NOT BE REPLICATED. IT IS CONCLUDED THAT SINCE THE SIMPLE PERSUADERS THAT WERE RETURNED FUNCTIONED AS INTENDED AND THE COMPLAINT CONDITION COULD NOT BE REPLICATED, THAT THIS COMPLAINT IS INVALID. THE THREADED PERSUADERS AND ONE LONG SIMPLE PERSUADER COULD NOT BE EVALUATED EITHER BECAUSE THEY WERE DISASSEMBLED AND THE NECESSARY PARTS WERE NOT RETURNED OR THE DEVICE ITSELF WAS NOT RETURNED.

Additional Manufacturer Narrative · 1

DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR.

Description of Event or Problem · 1

IT WAS REPORTED THAT DURING A POSTERIOR FUSION AT T10-S1, THE BLACK INNER PIECE OF THE MATRIX THREADED PERSUADER BROKE ON BOTH DEVICES WHILE THE SURGEON WAS PERSUADING. ALSO REPORTED, THE MATRIX THREADED PERSUADER, STANDARD AND A SECOND MATRIX THREADED PERSUADER LONG ARE BINDING UP AND STICKING. THE GEARS ON THE PERSUADERS ARE BINDING UP. THE HANDLE OF THE PERSUADERS DOES NOT SPRING BACK SMOOTHLY AS IT SHOULD ONCE SQUEEZED. THE BROKEN PIECE WAS RETRIEVED. THE SURGEON COMPLETED THE PROCEDURE WITH NO FURTHER PROBLEMS, AND NO HARM TO PATIENT. THIS IS REPORT 3 OF 3 FOR THIS EVENT.

Description of Event or Problem · 1

THIS IS REPORT 4 OF 4 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
105771 MATRIX SIMPLE PERSUADER-LONG LXH SYNTHES MONUMENT T953783

Patients

Seq Age Sex Outcome Treatment
1