- 1219977-2012-00227
- Event Type
- Injury
- Date Received
- January 2, 2013
- Date of Event
- May 21, 2012
- Report Date
- May 21, 2012
- Manufacturer
- ATRIUM MEDICAL CORP
- Product Code
- FTL
- PMA / PMN Number
- K100076
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- PHYSICIAN
Narratives
ON (B)(6) 2012, (B)(4) WAS ISSUED FOR A 4" X 6" C-QUR TACSHIELD MESH (PRODUCT CODE (B)(4), LOT #10734260018) THAT WAS USED FOR AN UMBILICAL HERNIA REPAIR AT (B)(6) HOSPITAL IN (B)(6) ON (B)(6) 2012. THE AUSTRALIAN INCIDENT REPORT STATES THAT "THE REPAIR WAS MADE IN A TENSION-FREE MANNER WITH A 10X15CM INTRAPERITONEAL COMPOSITE MESH (C-QUR TACSHIELD) WHICH WAS SUTURED TO THE DEFECT MARGINS AND ANCHORED WITH TACKS AT THE PERIMETER." IN ADDITION IT WAS NOTED THAT THE "PATIENT DEVELOPED DISCHARGE POST OP" AND THERE WAS "SEROMA EVIDENT AND SEROUS FLUID ASPIRATED." THE REPORT GOES ON TO SAY THAT THE RECORDS PROVIDED STATE THAT THE PT "PRESENTED 2 WEEKS LATER WITH GRANULOMA TISSUE AND SIGNS OF INFECTION." THE MEDICAL RECORDS PROVIDED STATE THAT THE PT WAS "PRESCRIBED A/B'S BY GP (2 COURSES) WITH NO EFFECT. MESH EXPLANTED 2 WEEKS LATER." THE C-QUR TACSHIELD MESH WAS EXPLANTED ON (B)(6) 2012 AND A PORTION WAS RETURNED TO ATRIUM FOR EVALUATION. THE SAMPLE WAS NOT RETURNED IN FORMALIN FIXATIVE AND WAS EVALUATED BY ATRIUM R+D ON (B)(6) 2012. .
PT HAD A UMBILICAL HERNIA REPAIR. AT OPERATION, A COMPLEX COLLECTION OF HERNIAS WERE ENCOUNTERED AT THE UMBILICUS. THERE WERE TRUE UMBILICAL DEFECTS TO THE LEFT AND RIGHT OF THE UMBILICAL STALK WITH PROTRUSION OF EXTRAPERITONEAL FAT. IN ADDITION, THERE WERE 2 SUPRAUMBILICAL HERNIAS OF THE LINEA ALBA, AGAIN WITH (LARGER) HERNIATION OF EXTRAPERITONEAL FAT. ALL DEFECTS WERE DEFINED AND THEN UNITED TO CREATE ONE DEFECT OF 5CM IN DIAMETER. THE REPAIR WAS MADE IN A TENSION-FREE MANNER WITH A 10X15CM INTRAPERITONEAL COMPOSITE MESH (CQUR TACSHIELD) WHICH WAS SUTURED TO THE DEFECT MARGINS AND ANCHORED WITH TACKS AT THE PERIMETER. PT DEVELOPED DISCHARGE POST OP. SEROMA EVIDENT AND SEROUS FLUID ASPIRATED. PRESENTED TWO WEEKS LATER WITH GRANULOMA TISSUE AND SIGNS OF INFECTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 974 | CQUR TACSHIELD | FTL | ATRIUM MEDICAL CORP | 31628 | 10734260 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |