CARPENTIER-EDWARDS PERIMOUNT RSR PERICARDIAL BIOPROSTHESIS
Report
- Report Number
- 2015691-2013-19208
- Event Type
- Injury
- Date Received
- February 6, 2013
- Date of Event
- December 3, 2012
- Report Date
- January 10, 2013
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- DYE
- PMA / PMN Number
- P860057/S001
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AZ, US
- Reporter Occupation
- OTHER
Narratives
BASED ON THE FOLLOW-UP WITH THE HEALTH-CARE PROVIDER, THE EXPLANT WAS DUE TO STENOSIS SECONDARY TO CALCIFICATION. NO OTHER DETAILS REPORTED. DESPITE REPEATED ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE EVENT NO ADDITIONAL INFORMATION WAS RECEIVED. THERE ARE SEVERAL POTENTIAL CAUSES FOR PROSTHETIC VALVE STENOSIS (E.G. CALCIFICATION, PANNUS GROWTH). UNFORTUNATELY, THE VALVE WAS NOT RETURNED TO EDWARDS FOR ANALYSIS, AND THEREFORE, THE ROOT CAUSE OF THIS EVENT COULD NOT BE INVESTIGATED. ALTHOUGH THE ROOT CAUSE CANNOT BE INVESTIGATED THE REPORTED STENOSIS WAS LIKELY DUE TO THE CALCIFICATION NOTED BY THE HEALTH-CARE PROVIDER. CALCIFICATION IS A WELL RECOGNIZED FAILURE MODE OF BIOPROSTHETIC VALVES. THE MECHANISMS FOR BIOPROSTHETIC HEART VALVE TISSUE CALCIFICATION ARE NOT FULLY UNDERSTOOD. MANY FACTORS CAN CONTRIBUTE TO THE ONSET AND PROPAGATION OF CALCIFICATION INCLUDING PATIENT RELATED (E.G. PATIENT AGE, DISEASE STATE, IMMUNE STATUS, AND OTHER CO-MORBIDITIES), PHARMACOLOGICAL, AND INTRINSIC PROPERTIES OF THE VALVE ITSELF. IT IS WIDELY UNDERSTOOD THAT PATIENTS WITH CHRONIC RENAL DISEASE AND PRIOR HISTORY OF CALCIFIC STENOSIS OF THE NATIVE VALVE MAY BE PREDISPOSED TO BIOPROSTHETIC CALCIFICATION. NO FURTHER ACTIONS ARE POSSIBLE WITH THE AVAILABLE INFORMATION.
DEVICE NOT RETURNED. DUE TO PATIENT PRIVACY REGULATIONS, THE HEALTH-CARE PROVIDER WAS NOT ABLE TO RELEASE ANY ADDITIONAL INFORMATION AS REQUESTED (E.G. OPERATIVE REPORT, DISCHARGE SUMMARY, ETC.). UNFORTUNATELY, THE SAMPLE DEVICE WAS NOT RETURNED. THEREFORE, THE ROOT CAUSE OF THIS EVENT COULD NOT BE CONCLUSIVELY DETERMINED. A SUPPLEMENTAL MDR WILL BE SUBMITTED IN THE EVENT THAT ANY NEW INFORMATION IS RECEIVED. NO FURTHER ACTIONS ARE POSSIBLE WITH THE AVAILABLE INFORMATION.
IN THIS CASE, IT WAS REPORTED THAT THE VALVE WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 9 YEARS. UNFORTUNATELY, THE REASON FOR EXPLANT HAS NOT BEEN PROVIDED. NO OTHER DETAILS REPORTED. DESPITE REPEATED ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE DEVICE AND EVENT, NO ADDITIONAL INFORMATION OR SAMPLE FOR EVALUATION WAS RECEIVED. THERE HAVE NOT BEEN ANY ALLEGATIONS OF A PRODUCT MALFUNCTION OR QUALITY DEFICIENCY. THE SUBJECT DEVICE WAS REPLACED WITH ANOTHER EDWARDS BIOPROSTHETIC VALVE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 50388 | CARPENTIER-EDWARDS PERIMOUNT RSR PERICARDIAL BIOPROSTHESIS | REPLACEMENT HEART VALVE | DYE | EDWARDS LIFESCIENCES | 2800 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 75 YR | Hospitalization| R |