COBAS E411 DISK SYSTEM
Report
- Report Number
- 1823260-2013-00544
- Event Type
- Malfunction
- Date Received
- January 30, 2013
- Date of Event
- January 22, 2013
- Report Date
- January 30, 2013
- Manufacturer
- ROCHE DIAGNOSTICS
- Product Code
- MMI
- PMA / PMN Number
- K961481
- Removal / Correction Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- ME, US
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
IT WAS UNKNOWN IF THE INITIAL REPORTER SENT REPORT TO THE FDA.
THE CUSTOMER REPORTED THAT THEY RECEIVED AN ERRONEOUS RESULT FOR ONE PATIENT SAMPLE TESTED FOR TROPONIN T STAT (SHORT TURN AROUND TIME). THE SAMPLE INITIALLY RESULTED AS 0.049 NG/ML ACCOMPANIED BY A DATA FLAG. THE SAMPLE WAS REPEATED AND RESULTED AS 0.115 NG/ML ACCOMPANIED BY A DATA FLAG. THE CUSTOMER THEN POURED OFF THE SAMPLE AND RAN IT IN A CUP FOR A SECOND REPEAT, RESULTING AS 0.053 NG/ML ACCOMPANIED BY A DATA FLAG. THE CUSTOMER ALSO PULLED AN EDTA TUBE FROM THE SAME COLLECTION AND RAN IT FOR A THIRD REPEAT, RESULTING AS 0.056 NG/ML ACCOMPANIED BY A DATA FLAG. THE ORIGINAL RESULT WAS BELIEVED TO BE CORRECT AND A RESULT OF 0.05 NG/ML WAS RELEASED OUTSIDE OF THE LABORATORY. THE PATIENT WAS NOT ADVERSELY AFFECTED BY THE EVENT. THE TROPONIN T STAT REAGENT LOT NUMBER WAS 17016701 WITH AN EXPIRATION DATE OF 11/30/2013. THE FIELD SERVICE REPRESENTATIVE DETERMINED THAT A HAIRLINE CRACK IN THE PLASTIC INSULATION TIP OF THE S/R PROBE AND A BENT SAMPLE SIPPER NOZZLE PROBE WERE CONTRIBUTING FACTORS. THERE WAS ALSO EXTREMELY LOW HUMITIDY OF 15% TO 19% IN THE LABORATOY AT THE LOCATION OF THE INSTRUMENT. HE REPLACED THE S/R PROBE AND TUBING. HE REPLACED THE SAMPLE SIPPER NOZZLE. HE ALSO REPLACED THE MEASURING CELL FOR PREVENTIVE MAINTENANCE PURPOSES. HE PERFORMED ALL PROBE ADJUSTMENTS, CHECKED LLD VOLTAGES AND PRESSURE SENSOR VOLTAGES. THE MIXER SPEED CHECKED GOOD. THE INCUBATOR, PC/CC, AND MEASURING CELL TEMPERATURES WERE ALL GOOD. THE PINCH TUBING WAS REPLACED. PERFORMANCE TESTS WERE PERFORMED WITH ALL RESULTS MEETING SPECIFICATIONS. THE OPERATOR PERFORMED CALIBRATIONS AND QUALITY CONTROL WITH ALL RESULTS FOR TROPONIN T STAT AND PROBNP MEETING SPECIFICATIONS. THE CALIBRATIONS HAD TO BE PERFORMED TWICE AND QUALITY CONTROLS REPEATED DUE TO CONTROL ISSUES AFTER THE FIRST GOOD CALIBRATION. CRITICAL HUMIDITY AND STATIC ISSUES WERE SUSPECTED WITHIN THE LAB. THE LABORATORY HUMIDITY WAS 15% ACCORDING TO THE FIELD SERVICE REPRESENTATIVE'S GUAGE AND 19% ON THE LABORATORY HUMIDITY GUAGE. STATIC ISSUES WERE NOTICED WITH CUPS. THE CUSTOMER WAS INFORMED OF THE INSTRUMENT HUMIDITY SPECIFICATIONS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 41301 | COBAS E411 DISK SYSTEM | IMMUNOCHEMISTRY ANALYZER | MMI | ROCHE DIAGNOSTICS | NA | NA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 088 YR | PERCOCET| LASIX| CARVEDILOL| ASPIRIN| LISINOPRIL| TAMSULOSIN| SYNTHYROID |