FDA Adverse Event Injury Summary report: N

TOTAL ASR ACET IMP SIZE 48

MDR report key: 2924018 · Received January 22, 2013

Report

Report Number
1818910-2013-01503
Event Type
Injury
Date Received
January 22, 2013
Date of Event
February 15, 2012
Report Date
October 14, 2014
Manufacturer
DEPUY INTERNATIONAL LTD - 8010379
Product Code
KWA
Removal / Correction Number
Z- 1749/1816-2011
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
AU
Reporter Occupation
PATIENT

Narratives

Additional Manufacturer Narrative · 1

THE ASR PLATFORM WAS VOLUNTARILY RECALLED FROM THE MARKET IN AUGUST 2010, AND THE ASR PRODUCT CODES ARE NOW CONSIDERED INACTIVE. FURTHER INVESTIGATION OF THIS INDIVIDUAL INCIDENT WILL NOT BE UNDERTAKEN, AS THERE IS AN ONGOING INVESTIGATION REGARDING THE ROOT CAUSE(S) AND/OR CORRECTIVE ACTIONS. (B)(4). DEPUY CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD THE PRODUCT AND/OR ADDITIONAL INFORMATION BE RECEIVED, THE INVESTIGATION WILL BE RE-OPENED. THE CORRECTION/REMOVAL REPORTING NUMBER LISTED APPLIES TO THE CORRESPONDING PRODUCT CODE SOLD DOMESTICALLY.

Additional Manufacturer Narrative · 1

IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.DEPUY STILL CONSIDERS THIS CASE CLOSED TO CAPA.

Additional Manufacturer Narrative · 1

(B)(4). INVESTIGATION SUMMARY: THE ASR PLATFORM WAS VOLUNTARILY RECALLED FROM THE MARKET IN AUGUST 2010, AND THE ASR PRODUCT CODES ARE NOW CONSIDERED INACTIVE. FURTHER INVESTIGATION OF THIS INDIVIDUAL INCIDENT WILL NOT BE UNDERTAKEN. THE INVESTIGATION REGARDING THE ROOT CAUSE(S) AND/OR CORRECTIVE ACTIONS WAS CONDUCTED UNDER MDD CAPA-(B)(4). ONGOING POST MARKET SURVEILLANCE IS CONDUCTED PER OUR PROCEDURES FOR THIS PRODUCT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

ASR REVISION HIP(S) TO BE REVISED: RIGHT TYPE OF HIP REPLACEMENT PRODUCT: ASR XL ACETABULAR SYSTEM REASON(S) FOR REVISION: PAIN.

Description of Event or Problem · 1

(B)(4). ASR REVISION.HIP(S) TO BE REVISED: RIGHT.TYPE OF HIP REPLACEMENT PRODUCT: ASR XL ACETABULAR SYSTEM.REASON(S) FOR REVISION: PAIN.(B)(4). THIS COM IS TO BE CLOSED TO CAPA DUE TO THE REASONS FOR REVISION FALLING WITHIN THE CAPA REMIT AND OFF LABEL USE OF A COMPETITOR STEM.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
29428 TOTAL ASR ACET IMP SIZE 48 HIP ACETABULAR CUP KWA DEPUY INTERNATIONAL LTD - 8010379 2215579

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention