FDA Adverse Event Injury Summary report: N

CARPENTIER-EDWARDS PERIMOUNT MAGNA PERICARDIAL BIOPROSTHESIS

MDR report key: 2922913 · Received January 18, 2013

Report

Report Number
2015691-2013-19149
Event Type
Injury
Date Received
January 18, 2013
Date of Event
November 30, 2012
Report Date
December 21, 2012
Manufacturer
EDWARDS LIFESCIENCES
Product Code
DYE
PMA / PMN Number
P860057/S018
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

DEVICE NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: DESPITE ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE DEVICE AND EVENT, NO ADDITIONAL INFORMATION OR SAMPLE FOR EVALUATION WAS RECEIVED. THEREFORE, THE ROOT CAUSE OF THIS EVENT COULD NOT BE CONFIRMED. THERE HAVE NOT BEEN ANY ALLEGATIONS OF A MALFUNCTION OR DEFICIENCY RELATED TO THE EXPLANTED VALVE. CONTINUED ATTEMPTS ARE BEING MADE TO OBTAIN ADDITIONAL DETAILS REGARDING THIS CASE. A SUPPLEMENTAL MDR WILL BE SUBMITTED IN THE EVENT ANY NEW INFORMATION IS RECEIVED.

Additional Manufacturer Narrative · 1

BASED ON THE FOLLOW-UP WITH THE HEALTH-CARE PROVIDER, THE EXPLANT WAS DUE TO ENDOCARDITIS, THE SOURCE WAS NOT PROVIDED. THE HEALTH-CARE PROVIDER NOTED THAT THE EXPLANT WAS NOT RELATED TO ANY DEVICE MALFUNCTION OR QUALITY DEFICIENCY. NO OTHER DETAILS PROVIDED. LATE PROSTHETIC VALVE ENDOCARDITIS, OCCURRING MORE THAN 60 DAYS AFTER SURGERY, IS USUALLY CAUSED BY AN INFECTION WHICH OCCURS ELSEWHERE IN THE BODY, AND THEN SEEDS THE VALVE. THE MOST FREQUENT CAUSES ARE DENTAL PROCEDURES, UROLOGICAL INFECTIONS AND INTERVENTIONS, AND INDWELLING CATHETERS. EDWARDS LIFESCIENCES HAS VALIDATED METHODS FOR STERILIZATION OF ALL DEVICES WHICH ENSURES PRODUCT STERILITY. UNFORTUNATELY, THE SUBJECT DEVICE WAS NOT RETURNED. THEREFORE, NO EVALUATION CAN BE PERFORMED. NO FURTHER ACTIONS ARE POSSIBLE WITH THE AVAILABLE INFORMATION.

Description of Event or Problem · 1

EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT." THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, IT WAS REPORTED THAT THE AORTIC VALVE WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 4 YEARS AND 9 MONTHS. THE REASON FOR EXPLANT IS UNKNOWN. DESPITE ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE DEVICE AND EVENT, NO ADDITIONAL INFORMATION OR SAMPLE FOR EVALUATION WAS RECEIVED. THERE HAVE NOT BEEN ANY ALLEGATIONS OF A MALFUNCTION OR DEFICIENCY RELATED TO THE EXPLANTED VALVE. THE EXPLANTED DEVICE WAS REPLACED WITH ANOTHER EDWARDS VALVE. NO OTHER DETAILS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
27712 CARPENTIER-EDWARDS PERIMOUNT MAGNA PERICARDIAL BIOPROSTHESIS REPLACEMENT HEART VALVE DYE EDWARDS LIFESCIENCES 3000

Patients

Seq Age Sex Outcome Treatment
1 45 YR Hospitalization| R