SYNERGY
Report
- Report Number
- 3007566237-2013-00174
- Event Type
- Injury
- Date Received
- January 14, 2013
- Date of Event
- November 1, 2012
- Report Date
- December 18, 2012
- Manufacturer
- MEDTRONIC NEUROMODULATION
- Product Code
- LGW
- PMA / PMN Number
- P840001
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- PHYSICIAN
Narratives
THE ACTUAL EVENT DATES WERE NOT PROVIDED. THIS DATE IS BASED ON THE DATE OF PUBLICATION OF THE ARTICLE. IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE EVENTS REPORTED WITH PREVIOUSLY REPORTED EVENTS. IT IS ALSO POSSIBLE SEVERAL EVENTS OCCURRED IN ONE PATIENT. CONCOMITANT MEDICAL PRODUCTS: PRODUCT ID 3487A, SERIAL# UNKNOWN. PRODUCT TYPE: LEAD. (B)(4).
LITERATURE: KISS, Z. H., BECKER, W. J. OCCIPITAL STIMULATION FOR CHRONIC MIGRAINE: PATIENT SELECTION AND COMPLICATIONS. THE CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES. 2012. 39(6): 807-12. SUMMARY: CHRONIC MIGRAINE IS A SIGNIFICANT CAUSE OF DISABILITY WORLD-WIDE AND OCCIPITAL REGION STIMULATION (OS) HAS BEEN PROPOSED TO TREAT IT. WHILE PARTICIPATING IN AN INDUSTRY-SPONSORED PILOT TRIAL OF OS, WE AIMED TO COLLECT DATA REGARDING OUR SURGICAL COMPLICATIONS AND LONG TERM USAGE OF OS IN OUR CHRONIC MIGRAINE PATIENTS. TEN PATIENTS (8 FEMALE, MEDIAN AGE (B)(6)) WERE ENROLLED BASED ON CRITERIA ESTABLISHED BY THE SPONSORING COMPANY, SCREENED IN THE HEADACHE CLINIC, AND FOLLOWED FOR A MEDIAN OF 33 MONTHS. WE DID NOT ACCESS DATA COLLECTED BY INDUSTRY FOR THIS REPORT AND INSTEAD COLLECTED OUR OWN DATA PROSPECTIVELY, INCLUDING PREDOMINANT LOCATION OF HEADACHE, LOCATION OF PARESTHESIA EVOKED BY OS, AND COMPLICATIONS. ADVERSE EVENTS INCLUDED THREE POSSIBLE EARLY INFECTIONS REQUIRING ANTIBIOTICS BUT NOT HARDWARE REMOVAL, ONE LATE IMPLANTABLE PULSE GENERATOR EROSION REQUIRING REMOVAL, ONE GENERATOR MALFUNCTION REQUIRING REVISION, AND LOSS OF PARESTHETIC COVERAGE REQUIRING FOUR REVISIONS IN FOUR PATIENTS. TWO PATIENTS EXPERIENCED NEW SYMPTOMS REQUIRING PSYCHIATRIC INTERVENTION. FIVE PATIENTS HAD NO BENEFIT AND HAVE BEEN EXPLANTED. OF THOSE WHO REMAIN USING THEIR DEVICE, THE PROPORTION OF THEIR PRE-OPERATIVE PAIN LOCATED IN THE OCCIPITAL REGION WAS 0.62 ± 0.14, WHEREAS IN THOSE PATIENTS WHO HAVE BEEN EXPLANTED, THE PROPORTION WAS 0.31 ± 0.18 (T = 3.15, P=0.01). COMPLICATION RATES WITH OS ARE HIGHER THAN THOSE SEEN WITH OTHER STIMULATION TECHNIQUES, DESPITE IDENTICAL HARDWARE AND SIMILAR SURGERY. THE LOCATION OF MIGRAINE PAIN DID PREDICT OUTCOME, AND SUGGESTS THAT ONLY THOSE WITH PRIMARILY OCCIPITAL REGION HEADACHE ARE CANDIDATES FOR THIS THERAPY. REPORTED EVENT: A (B)(6) FEMALE WITH NO PRIOR PSYCHIATRIC ISSUES HAD SIGNIFICANT DEPRESSION REQUIRING IN-PATIENT MANAGEMENT. THIS EVENT WAS ORIGINALLY REPORTED UNDER MASTER REGULATORY REPORT #3007566237-2012-03137. ADDITIONAL INFORMATION WAS RECEIVED WHICH PROVIDED PATIENT INFORMATION, INDICATING THE EVENT SHOULD BE REPORTED IN ITS OWN REGULATORY REPORT. ADDITIONAL INFORMATION HAS BEEN REQUESTED AND ANY ADDITIONAL INFORMATION RECEIVED WILL BE REPORTED AS A SUPPLEMENTAL REPORT TO THIS REGULATORY REPORT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 19811 | SYNERGY | STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF | LGW | MEDTRONIC NEUROMODULATION | 7427 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00032 YR | Hospitalization |