Narratives
THE ACTUAL EVENT DATES WERE NOT PROVIDED. THIS DATE IS BASED ON THE DATE OF PUBLICATION OF THE ARTICLE. IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE EVENTS REPORTED WITH PREVIOUSLY REPORTED EVENTS. IT IS ALSO POSSIBLE SEVERAL EVENTS OCCURRED IN ONE PATIENT. CONCOMITANT MEDICAL PRODUCTS: PRODUCT ID: NEU_UNKNOWN_EXT, SERIAL# UNKNOWN. PRODUCT TYPE: EXTENSION: PRODUCT ID 3550-39, SERIAL# UNKNOWN. PRODUCT TYPE: ACCESSORY: PRODUCT ID 3487A, SERIAL# UNKNOWN. PRODUCT TYPE: LEAD. (B)(4).
KISS, Z. H., BECKER, W. J. OCCIPITAL STIMULATION FOR CHRONIC MIGRAINE: PATIENT SELECTION AND COMPLICATIONS. THE CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES. 2012. 39(6): 807-12. SUMMARY: CHRONIC MIGRAINE IS A SIGNIFICANT CAUSE OF DISABILITY WORLD-WIDE AND OCCIPITAL REGION STIMULATION (OS) HAS BEEN PROPOSED TO TREAT IT. WHILE PARTICIPATING IN AN INDUSTRY-SPONSORED PILOT TRIAL OF OS, WE AIMED TO COLLECT DATA REGARDING OUR SURGICAL COMPLICATIONS AND LONG TERM USAGE OF OS IN OUR CHRONIC MIGRAINE PATIENTS. TEN PATIENTS (8 FEMALE, MEDIAN AGE 46.5 YEARS) WERE ENROLLED BASED ON CRITERIA ESTABLISHED BY THE SPONSORING COMPANY, SCREENED IN THE HEADACHE CLINIC, AND FOLLOWED FOR A MEDIAN OF 33 MONTHS. WE DID NOT ACCESS DATA COLLECTED BY INDUSTRY FOR THIS REPORT AND INSTEAD COLLECTED OUR OWN DATA PROSPECTIVELY, INCLUDING PREDOMINANT LOCATION OF HEADACHE, LOCATION OF PARESTHESIA EVOKED BY OS, AND COMPLICATIONS. ADVERSE EVENTS INCLUDED THREE POSSIBLE EARLY INFECTIONS REQUIRING ANTIBIOTICS BUT NOT HARDWARE REMOVAL, ONE LATE IMPLANTABLE PULSE GENERATOR EROSION REQUIRING REMOVAL, ONE GENERATOR MALFUNCTION REQUIRING REVISION, AND LOSS OF PARESTHETIC COVERAGE REQUIRING FOUR REVISIONS IN FOUR PATIENTS. TWO PATIENTS EXPERIENCED NEW SYMPTOMS REQUIRING PSYCHIATRIC INTERVENTION. FIVE PATIENTS HAD NO BENEFIT AND HAVE BEEN EXPLANTED. OF THOSE WHO REMAIN USING THEIR DEVICE, THE PROPORTION OF THEIR PRE-OPERATIVE PAIN LOCATED IN THE OCCIPITAL REGION WAS 0.62 ± 0.14, WHEREAS IN THOSE PATIENTS WHO HAVE BEEN EXPLANTED, THE PROPORTION WAS 0.31 ± 0.18 (T = 3.15, P=0.01). COMPLICATION RATES WITH OS ARE HIGHER THAN THOSE SEEN WITH OTHER STIMULATION TECHNIQUES, DESPITE IDENTICAL HARDWARE AND SIMILAR SURGERY. THE LOCATION OF MIGRAINE PAIN DID PREDICT OUTCOME, AND SUGGESTS THAT ONLY THOSE WITH PRIMARILY OCCIPITAL REGION HEADACHE ARE CANDIDATES FOR THIS THERAPY. REPORTED EVENT: A (B)(6) FEMALE EXPERIENCED INCISIONAL INFLAMMATION AFTER IMPLANT. THE PATIENT RECEIVED IV AND ORAL ANTIBIOTICS. NEITHER BLOOD NOR WOUND CULTURES IDENTIFIED BACTERIAL GROWTH. REMOVAL OF THE DEVICE WAS NOT NECESSARY. THIS EVENT WAS ORIGINALLY REPORTED UNDER MASTER REGULATORY REPORT #3007566237-2012-03137. ADDITIONAL INFORMATION WAS RECEIVED WHICH PROVIDED PATIENT INFORMATION, INDICATING THE EVENT SHOULD BE REPORTED IN ITS OWN REGULATORY REPORT. ADDITIONAL INFORMATION HAS BEEN REQUESTED AND ANY ADDITIONAL INFORMATION RECEIVED WILL BE REPORTED AS A SUPPLEMENTAL REPORT TO THIS REGULATORY REPORT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 20228 | SYNERGY | STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF | LGW | MEDTRONIC NEUROMODULATION | 7427 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00038 YR | Required Intervention |