ACCOLADE 132 SIZE 5.5
Report
- Report Number
- 9616680-2013-90018
- Event Type
- Injury
- Date Received
- January 7, 2013
- Date of Event
- November 15, 2012
- Report Date
- December 12, 2012
- Manufacturer
- STRYKER ORTHOPAEDICS CORK
- Product Code
- MEH
- PMA / PMN Number
- K994366
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- NURSE
Narratives
A SUPPLEMENTAL REPORT WILL BE SUBMITTED UPON COMPLETION OF THE INVESTIGATION.
THE CUSTOMER REPORTED: "THIS PT HAD UNDERGONE RIGHT HIP REPLACEMENT IN 2010. IMPLANT USED WAS UNCEMENTED ACCOLADE STEM AND TRIDENT CUP (STRYKER) WITH 36 MM COBALT CHROME HEAD AND CROSSLINKED POLYETHYLENE LINER. DURING THE POSTOPERATIVE PERIOD, THE PROSTHESIS SUBSIDED, AND AS A RESULT HIS LEG WAS SHORTER BY APPROX 20 MM. THE OFFSET APPEARED NOT RECONSTRUCTED AT THE INITIAL SURGERY. THE PT WAS SEEN IN THE (B)(6) 2012. HE HAD SIGNIFICANT DIFFICULTIES WALKING DUE TO HIS LEG LENGTH DIFFERENCE. AFTER OBTAINING MEDICAL RECORDS FROM THE ORIGINAL HOSPITAL, WE OPTED TO REVISE THE HIP REPLACEMENT TO RESTORE LEG LENGTH AND OFFSET. AS A ROUTINE PREOPERATIVE INVESTIGATION, A HIP JOINT NEEDLE ASPIRATE WAS OBTAINED WHICH RETURNED WHITE MILKY FLUID TYPICAL OF METAL DEBRIS REACTION. METAL ION LEVELS WERE RAISED (CHROMIUM 1.14 MICROGRAMS/L, COBALT 2.40 MICROGRAMS/L). THE FLUID SAMPLE WAS FROZEN AND NOT PROCESSED. AN MRI RULED OUT SEVERE ALVAL. INTRAOPERATIVELY DURING THE REVISION SURGERY, A RELATIVELY LARGE AMOUNT OF WHITE MILKY FLUID WAS DRAINED. THE PROSTHESIS WAS WELL FIXED. ON REMOVAL OF THE MODULAR 36 MM HEAD, CORROSION AT THE TRUNION/HEAD TAPER JUNCTION WAS EVIDENT. PHOTOS WERE TAKEN. THE PROSTHESIS WAS REMOVED AS PLANNED, AND A NEW ONE INSERTED WHICH RECONSTRUCTED LEG LENGTH AND OFFSET FULLY. IT IS UNUSUAL FOR A METAL-ON-POLYETHYLENE ARTICULATION TO PRODUCE A SUFFICIENTLY LARGE AMOUNT OF METAL ION DEBRIS TO ELICIT A LOCAL REACTION; AND TO RAISE BLOOD LEVELS. THE PROBLEM COULD BE DUE TO THE SMALL DIAMETER OF THE TRUNION RELATIVE TO THE HEAD DIAMETER, WHICH WOULD GENERATE SIGNIFICANT TORSIONAL FORCES AT THE HEAD/TRUNION INTERFACE. METAL DEBRIS REACTION AND CORROSION OF THE TRUNION/HEAD TAPER JUNCTION."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 8112 | ACCOLADE 132 SIZE 5.5 | IMPLANT | MEH | STRYKER ORTHOPAEDICS CORK | NA | 28250903 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | UNK | Other| R |