FDA Adverse Event Injury Summary report: N

CARPENTIER-EDWARDS PERIMOUNT MAGNA PERICARDIAL BIOPROSTHESIS

MDR report key: 2904913 · Received January 9, 2013

Report

Report Number
2015691-2013-19058
Event Type
Injury
Date Received
January 9, 2013
Date of Event
November 13, 2012
Report Date
December 11, 2012
Manufacturer
EDWARDS LIFESCIENCES
Product Code
DYE
PMA / PMN Number
P860057/S022
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
OR, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

DEVICE NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: THERE ARE SEVERAL POTENTIAL CAUSES FOR PROSTHETIC VALVE STENOSIS (E.G. CALCIFICATION, PANNUS GROWTH). UNFORTUNATELY, THE VALVE WAS NOT RETURNED TO EDWARDS FOR ANALYSIS, AND THEREFORE, THE ROOT CAUSE OF THIS EVENT COULD NOT BE INVESTIGATED. ALTHOUGH THE ROOT CAUSE CANNOT BE INVESTIGATED, THE REPORTED STENOSIS WAS LIKELY DUE TO THE CALCIFICATION NOTED BY THE HEALTH-CARE PROVIDER. THE HEALTH-CARE PROVIDER ALSO NOTED THAT THE "PATIENT OUT-GREW THE VALVE". CALCIFICATION IS A WELL RECOGNIZED FAILURE MODE OF BIOPROSTHETIC VALVES. THE MECHANISMS FOR BIOPROSTHETIC HEART VALVE TISSUE CALCIFICATION ARE NOT FULLY UNDERSTOOD. MANY FACTORS CAN CONTRIBUTE TO THE ONSET AND PROPAGATION OF CALCIFICATION INCLUDING PATIENT RELATED (E.G. PATIENT AGE, DISEASE STATE, IMMUNE STATUS, AND OTHER CO-MORBIDITIES), PHARMACOLOGICAL, AND INTRINSIC PROPERTIES OF THE VALVE ITSELF. IT IS WIDELY UNDERSTOOD THAT PATIENTS WITH CHRONIC RENAL DISEASE AND PRIOR HISTORY OF CALCIFIC STENOSIS OF THE NATIVE VALVE MAY BE PREDISPOSED TO BIOPROSTHETIC CALCIFICATION. NO FURTHER ACTIONS ARE POSSIBLE WITH THE AVAILABLE INFORMATION.

Description of Event or Problem · 1

EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A (B)(4) SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, IT WAS REPORTED THAT THE VALVE WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 5 YEARS AND 5 MONTHS DUE TO AORTIC STENOSIS SECONDARY TO CALCIFICATION. PER THE HEALTH-CARE PROVIDER, THE EXPLANT WAS PATIENT RELATED AND NOT RELATED TO ANY DEVICE MALFUNCTION. THE HEALTH-CARE PROVIDER ALSO NOTED THAT THE "PATIENT OUT-GREW THE VALVE". THE SUBJECT DEVICE WAS REPLACED WITH ANOTHER EDWARDS BIOPROSTHETIC VALVE. NO OTHER DETAILS REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
11948 CARPENTIER-EDWARDS PERIMOUNT MAGNA PERICARDIAL BIOPROSTHESIS REPLACEMENT HEART VALVE DYE EDWARDS LIFESCIENCES 3000TFX

Patients

Seq Age Sex Outcome Treatment
1 16 YR Hospitalization| R