ASR UNI FEMORAL IMPL SIZE 45
Report
- Report Number
- 1818910-2013-00309
- Event Type
- Injury
- Date Received
- January 3, 2013
- Report Date
- August 5, 2013
- Manufacturer
- DEPUY INTERNATIONAL
- Product Code
- KWA
- PMA / PMN Number
- K040627
- Removal / Correction Number
- Z-1749/1816-2011
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- ATTORNEY
Narratives
EXAMINATION OF THE REPORTED DEVICES WAS NOT POSSIBLE AS THEY WERE NOT RETURNED. A SEARCH OF THE COMPLAINTS DATABASES FINDS NO OTHER REPORTS AGAINST THE STEM/SLEEVE PRODUCT AND LOT CODE COMBINATIONS SINCE THEIR RELEASE TO DISTRIBUTION. THE INVESTIGATION CAN DRAW NO CONCLUSIONS WITH THE INFORMATION PROVIDED. IT SHOULD BE NOTED THAT THE REPORTED CORROSION WAS SAID TO HAVE BEEN WIPED OFF IN SURGERY. THE ASR PLATFORM WAS VOLUNTARILY RECALLED FROM THE MARKET IN AUGUST 2010, AND THE ASR PRODUCT CODES ARE NOW CONSIDERED INACTIVE. FURTHER INVESTIGATION OF THIS INDIVIDUAL INCIDENT WILL NOT BE UNDERTAKEN, AS THERE IS AN ONGOING INVESTIGATION REGARDING THE ROOT CAUSE(S) AND/OR CORRECTIVE ACTIONS. (B)(4).DEPUY CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD THE PRODUCT AND/OR ADDITIONAL INFORMATION BE RECEIVED, THE INVESTIGATION WILL BE RE-OPENED.
DEPUY STILL CONSIDERS THIS COMPLAINT CLOSED.
THE ASR PLATFORM WAS VOLUNTARILY RECALLED FROM THE MARKET IN AUGUST 2010, AND THE ASR PRODUCT CODES ARE NOW CONSIDERED INACTIVE. FURTHER INVESTIGATION OF THIS INDIVIDUAL INCIDENT WILL NOT BE UNDERTAKEN, AS THERE IS AN ONGOING INVESTIGATION REGARDING THE ROOT CAUSE(S) AND/OR CORRECTIVE ACTIONS. (B)(4). DEPUY CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD THE PRODUCT AND/OR ADDITIONAL INFORMATION BE RECEIVED, THE INVESTIGATION WILL BE RE-OPENED.
THERE IS NO NEW INFORMATION THAT WOULD CHANGE THE OUTCOME OF THE INVESTIGATION. THE COMPLAINT IS STILL CONSIDERED CLOSED.
UPDATE: - MEDICAL RECORDS RECEIVED (B)(6) 2013. REVISION OPERATIVE REPORT INDICATES THE FOLLOWING: LARGE METALLIC STAINED BURSA; MARKED NECROSIS AND ABSENCE OF THE EXTERNAL ROTATORS; SOME DESTRUCTION OF THE GLUTEUS MINIMUM; POSTERIOR CAPSULE WAS ABSENT AS WERE THE EXTERNAL ROTATORS. THE INFORMATION RECEIVED DOES NOT CHANGE THE MDR DECISION.
LITIGATION PAPERS ALLEGE THAT THE BILATERAL PATIENT SUFFERED FROM HIP PAIN, BACK AND GROIN PAIN, INABILITY TO STAND FOR LONG PERIODS OF TIME, DIFFICULTY WALKING, WALKED WITH A LIMP, BLURRINESS AND VISION PROBLEMS AND WAS INJURED BY EXCESSIVE LEVELS OF CHROMIUM AND COBALT IN HER BLOOD.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 3231 | ASR UNI FEMORAL IMPL SIZE 45 | TOTAL HIP REPLACEMENT | KWA | DEPUY INTERNATIONAL | 2005208 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |