FDA Adverse Event Malfunction Summary report: N

POWERED WHEELCHAIR

MDR report key: 2893830 · Received January 2, 2013

Report

Report Number
1525712-2013-00026
Event Type
Malfunction
Date Received
January 2, 2013
Report Date
January 2, 2013
Manufacturer
INVACARE TAYLOR STREET
Product Code
ITI
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
MEDICAL EQUIPMENT COMPANY TECHNICIAN/REPRESENTATIVE

Narratives

Description of Event or Problem · 1

INITIAL REPORT RECEIVED INDICATING WITH BACK AND FORTH MOVEMENT OF THE SWING AWAY JOYSTICK MOUNT, THE END OF CABLE PART #1127293 THAT ATTACHES INTO THE BACK OF THE JOYSTICK GETS PINCHED OR FRAYED ALLOWING THE CONTROLLER AND JOYSTICK TO NOT COMMUNICATE. IT WAS LEARNED THE REPORTER IS REPLACING THE ORIGINAL CABLE WITH A LONGER ONE THUS ADDING MORE LENGTH TO THE CABLE SO ITS NOT SO TIGHT. IT SEEMS TO BE RESOLVING THE ISSUE FOR HIM.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
721 POWERED WHEELCHAIR 890.3860 ITI INVACARE TAYLOR STREET TDXSP

Patients

Seq Age Sex Outcome Treatment
1 Other