LAP-BAND AP ADJUSTABLE GASTRIC BANDING SYSTEM (STANDARD)
Report
- Report Number
- 2024601-2012-01318
- Event Type
- Injury
- Date Received
- December 26, 2012
- Date of Event
- May 30, 2012
- Report Date
- December 5, 2012
- Manufacturer
- ALLERGAN
- Product Code
- LTI
- PMA / PMN Number
- P000008
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NC, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). THE REPORTER OF THE COMPLAINT WAS ASKED TO RETURN THE PRODUCT FOR ANALYSIS. THE PRODUCT ASSOCIATED WITH THIS REPORT WILL NOT BE RETURNED. BASED UPON THE MODEL NUMBER, SERIAL NUMBER AND IMPLANT DATE PROVIDED BY THE REPORTER THE CONNECTOR TYPE IS ASSUMED TO BE A TAPER II. EROSION AND INFECTION ARE SURGICAL/PHYSIOLOGICAL COMPLICATIONS AND ANALYSIS OF THE DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THESE EVENTS. DEVICE LABELING ADDRESSES THE POSSIBLE OUTCOME OF EROSION AS FOLLOWS: "THERE IS A RISK OF BAND EROSION INTO STOMACH TISSUE. EROSION OF THE BAND INTO STOMACH TISSUE HAS BEEN ASSOCIATED WITH REVISION SURGERY, AFTER THE USE OF GASTRIC IRRITATING MEDICATIONS, AFTER STOMACH DAMAGE AND AFTER EXTENSION DISSECTION OR USE OF ELECTRO-CAUTERY, AND DURING EARLY EXPERIENCE. SYMPTOMS OF BAND EROSION MAY INCLUDE REDUCED WEIGHT LOSS, WEIGHT GAIN, ACCESS PORT INFECTION, OR ABDOMINAL PAIN. RE-OPERATION TO REMOVE THE DEVICE IS REQUIRED." "RE-OPERATION FOR BAND EROSIONS MAY RESULT IN A GASTRECTOMY OF THE AFFECTED AREA. ERODED BANDS HAVE BEEN REMOVED GASTROSCOPICALLY IN A VERY FEW CASES, DEPENDING ON THE DEGREE OF EROSION, CONSULTATION WITH OTHER EXPERIENCED LAP-BAND SYSTEM SURGEONS IS STRONGLY ADVISED IN THESE CASES." DEVICE LABELING ADDRESSES THE POSSIBLE OUTCOME OF AN INFECTION AS FOLLOW: "CONTRAINDICATIONS THE LAP-BAND SYSTEM IS CONTRAINDICATED IN: PATIENTS WHO HAVE AN INFECTION ANYWHERE IN THEIR BODY OR WHERE THE POSSIBILITY OF CONTAMINATION PRIOR TO OR DURING THE SURGERY EXISTS." DEVICE LABELING ADDRESSES THE POSSIBLE OUTCOME OF AN INFECTION AND EROSION AS FOLLOWS: (B)(4).
HEALTH PROFESSIONAL REPORTED A LAP-BAND SYSTEM EXPLANT DUE TO EROSION. A "S/P SX [STATUS POST SURGERY] INFECTION" WAS ALSO NOTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LAP-BAND AP ADJUSTABLE GASTRIC BANDING SYSTEM (STANDARD) | LTI | ALLERGAN | BA | 1713401 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 63 YR | Required Intervention |