LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM (UNK SIZE)
Report
- Report Number
- 2024601-2012-01356
- Event Type
- Injury
- Date Received
- December 21, 2012
- Date of Event
- November 28, 2012
- Report Date
- December 4, 2012
- Manufacturer
- ALLERGAN
- Product Code
- LTI
- PMA / PMN Number
- P000008
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- NO INFORMATION
Narratives
(B)(4). THE REPORTER OF THE COMPLAINT WAS ASKED TO RETURN THE PRODUCT FOR ANALYSIS AS WELL AS INDICATE THE PRODUCT SERIAL NUMBER, DATE OF EVENT, IMPLANT DATE AND EXPLANT DATE. THE INFO HAS NOT YET BEEN RECEIVED BY ALLERGAN. THE CONNECTOR TYPE CANNOT BE IDENTIFIED NOR AN ASSUMPTION MADE AS TO THE TYPE OF CONNECTOR ASSOCIATED WITH THIS COMPLAINT BECAUSE NO SERIAL NUMBER OR IMPLANT DATE WAS GIVEN. VISUAL EXAMINATION MAY DETERMINE THE CONNECTOR TYPE ASSOCIATED WITH THIS REPORT. ALLERGAN HAS NOT RECEIVED THE PRODUCT AT THIS TIME. THEREFORE, NO ANALYSIS OR TESTING HAS BEEN DONE. OBSTRUCTION IS A SURGICAL/PHYSICAL COMPLICATION AND ANALYSIS OF DEVICE GENERALLY DOES NOT ASSIST. ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THIS EVENT. DEVICE LABELING ADDRESSES THE REPORTED EVENT OF OBSTRUCTION AS FOLLOWS: "OBSTRUCTION OF STOMAS HAS BEEN REPORTED AS BOTH AN EARLY AND A LATE COMPLICATION OF THIS PROCEDURE. THIS CAN BE CAUSED BY EDEMA, FOOD, IMPROPER INITIAL CALIBRATION, BAND SLIPPAGE, POUCH TORSION, OR PT NONCOMPLIANCE REGARDING CHOICE AND CHEWING OF FOOD." "PTS MUST BE CAUTIONED TO CHEW THEIR FOOD THOROUGHLY. PTS WITH DENTURES MUST BE PARTICULARLY CAREFUL TO CUT THEIR FOOD INTO SMALL PIECES. FAILURE TO FOLLOW THESE PRECAUTIONS MAY RESULT IN VOMITING, STOMAL IRRITATION AND EDEMA, POSSIBLY EVEN OBSTRUCTION."
REPORTED EVENTS OF INTOLERANCE, BAND SLIPPAGE, EROSION, INFECTION, AND "COMPLETE BLOCKAGE" FROM JOURNAL ARTICLE: "LAPAROSCOPIC SLEEVE GASTRECTOMY (LSG) - A GOOD BARIATRIC OPTION FOR FAILED LAPAROSCOPIC ADJUSTABLE GASTRIC BANDING (LAGB): A REVIEW OF 90 PTS", OBES SURG, DOI 10.10007/S11695-012-0825-7. MANUFACTURER OF DEVICE IS UNK. IT IS ALLERGAN'S APPROACH TO COMPLIANCE TO RESOLVE ALL DOUBT IN FAVOR OF REPORTING. THIS MEDWATCH REPRESENTS THE 3 CASES OF "BLOCKAGE".
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LAP-BAND ADJUSTABLE GASTRIC BANDING SYSTEM (UNK SIZE) | LTI | ALLERGAN | NA | NI |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NI | Hospitalization| R | NO INFO |