Additional Manufacturer Narrative · 1

DATE OF BIRTH: (B)(6) 1939. IF IMPLANTED, GIVE DATE: (B)(6) 2008. DEVICE IS COMBINATION PRODUCT. DEVICE EVALUATED BY MFR: IT IS INDICATED THAT THE DEVICE WILL NOT BE RETURNED FOR EVALUATION; THEREFORE, A FAILURE ANALYSIS OF THE COMPLAINT DEVICE COULD NOT BE COMPLETED. A REVIEW OF THE BATCH HISTORY, HISTORICAL TRENDING AND SIMILAR COMPLAINT TRENDING REVIEW FOR THE PRODUCT FAMILY WILL BE CONDUCTED. IF THERE IS ANY FURTHER RELEVANT INFORMATION FROM THAT REVIEW, A SUPPLEMENTAL MEDWATCH WILL BE FILED. (B)(4).

Description of Event or Problem · 1

(B)(4) STUDY. SAME PATIENT AS MDR# 2134265-2009-01574, 2134265-2010-0128, 2134265-2010-02194, 2134265-2012-02584, 2134265-2012-02585, AND 2134265-2012-02586. SAME CASE AS MDR# 2134265-2012-08271 AND 2134265-2012-08269. IT WAS REPORTED THAT POST A STENTING TREATMENT PROCEDURE, THE PATIENT EXPERIENCE ANGINA AND VESSEL OCCLUSION OCCURRED. IN (B)(6) 2008, THE PHYSICIAN OBSERVED 75% RESTENOSIS MEASURING 21MM IN LENGTH LOCATED IN THE PREVIOUSLY STENT LAD, WITH A REFERENCE VESSEL DIAMETER OF 2.5MM. THE PHYSICIAN TREATED THE IN-STENT RESTENOSIS WITH PLACEMENT OF AN UNKNOWN SIZED TAXUS EXPRESS2 STENT, RESULTING IN 0% RESIDUAL STENOSIS. IN (B)(6) 2012, THE PATIENT PRESENTED WITH STABLE ANGINA. STENOSIS AS FOUND IN THE PROXIMAL LAD AND TARGET LESION REVASCULARIZATION WAS PERFORMED. THE 90% STENOSED, 15MM X 3.50MM TARGET LESION WAS TREATED WITH BALLOON ANGIOPLASTY WITH 25% RESIDUAL STENOSIS. THE PATIENT WAS CONSIDERED IMPROVED AND DISCHARGED TWO DAYS LATER. IN (B)(6), NON-TARGET VESSEL REVASCULARIZATION WAS PERFORMED. IN (B)(6) 2012, STENOSIS WAS FOUND IN THE PROXIMAL LAD AND TARGET LESION REVASCULARIZATION WAS PERFORMED. THE PATIENT HAD NO ISCHEMIC SYMPTOMS. THE 90% STENOSED, 15MM X 3.50MM TARGET LESION WAS TREATED WITH BALLOON ANGIOPLASTY WITH 25% RESIDUAL STENOSIS. A ROTOBLATOR AND AN UNSPECIFIED CUTTING BALLOON WERE USED DURING THE PROCEDURE. THE PATIENT WAS CONSIDERED IMPROVED AND DISCHARGED TWO DAYS LATER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 TAXUS EXPRESS2 PACLITAXEL-ELUTING CORONARY STENT SYSTEM CORONARY DRUG-ELUTING STENT NIQ BOSTON SCIENTIFIC - GALWAY UNK432

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention