FDA Adverse Event Injury Summary report: N

EXPRESS VASCULAR LD

MDR report key: 2881095 · Received December 20, 2012

Report

Report Number
2134265-2012-07819
Event Type
Injury
Date Received
December 20, 2012
Date of Event
November 29, 2012
Report Date
November 30, 2012
Manufacturer
BOSTON SCIENTIFIC - GALWAY
Product Code
FGE
PMA / PMN Number
SIMILAR
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

AGE AT TIME OF EVENT: 18 YEARS OR OLDER. (B)(4). DEVICE EVALUATED BY MANUFACTURER: IT IS INDICATED THAT THE DEVICE WILL NOT BE RETURNED FOR EVALUATION; THEREFORE A FAILURE ANALYSIS OF THE COMPLAINT DEVICE COULD NOT BE COMPLETED. A REVIEW OF THE BATCH HISTORY, HISTORICAL TRENDING, AND SIMILAR COMPLAINT TRENDING REVIEW FOR THE PRODUCT FAMILY WILL BE CONDUCTED. IF THERE IS ANY FURTHER RELEVANT INFORMATION FROM THAT REVIEW, A SUPPLEMENTAL MEDWATCH WILL BE FILED. (B)(4).

Description of Event or Problem · 1

SAME CASE AS MDR ID# 2134265-2012-07767. SAME CASE AS MDR ID# 2134265-2012-07768. IT WAS REPORTED THAT DURING A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY TREATMENT PROCEDURE, A STENT DEPLOYMENT ISSUE OCCURRED. VASCULAR ACCESS WAS OBTAINED VIA THE FEMORAL ARTERY USING A 7F 25 CM NON BSC INTRODUCER SHEATH. A .035 GUIDE WIRE SUCCESSFULLY CROSSED THE TARGET LESION. FOR PREDILATION A 8.0 X 20, 75 CM MUSTANG BALLOON CATHETER WAS ADVANCED TO THE TARGET LESION. DURING THE FIRST INFLATION AT 10 ATMS, A BALLOON RUPTURE OCCURRED. THE MUSTANG BALLOON CATHETER WAS REMOVED INTACT. A 8.0-40, 135 WANDA BALLOON CATHETER WAS ADVANCED TO THE TARGET LESION AND DILATION WAS PERFORMED. AN EXPRESS VASCULAR LD STENT WAS DEPLOYED AT THE TARGET LESION, HOWEVER DUE TO THE DEGREE OF VESSEL CALCIFICATION THE STENT DID NOT FULLY APPOSE TO THE VESSEL WALL BUT REMAINED IN POSITION. THE SDS WAS REMOVED AND THE STENT WAS DILATED WITH THE 8.0-40, 135 WANDA BALLOON CATHETER. DURING THE FIRST INFLATION AT 12 ATMS, A BALLOON RUPTURE OCCURRED. THE WANDA BALLOON CATHETER WAS REMOVED INTACT AND THE STENT WAS SUCCESSFULLY DEPLOYED WITH A 8-40 MM MUSTANG BALLOON CATHETER. NO FURTHER PATIENT COMPLICATIONS WERE REPORTED AND THE PATIENT'S STATUS IS LISTED AS STABLE. THIS PRODUCT IS ONLY OUS APPROVED, BUT IT IS SIMILAR TO AN APPROVED US DEVICE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 EXPRESS VASCULAR LD CATHETER, BILIARY, DIAGNOSTIC FGE BOSTON SCIENTIFIC - GALWAY UNK672

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention GUIDE WIRE, 035 RADIFOCUS| BALLOON CATHETER, 8.0-40, 135 WANDA| BALLOON CATHETER, 8.0 X 20, 75 CM MUSTANG| INTRODUCER SHEATH, 7F 25 CM ZEON