FDA Adverse Event Other Summary report: N

FUJINON

MDR report key: 2877807 · Received December 13, 2012

Report

Report Number
2431293-2012-00005
Event Type
Other
Date Received
December 13, 2012
Date of Event
March 8, 2011
Report Date
December 13, 2012
Manufacturer
FUJIFILM CORP.
Product Code
EOQ
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NC, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

ON (B)(4)2012, FUJIFILM MEDICAL SYSTEMS (B)(4) FIELD SERVICE ENGINEER VISITED THE USER FACILITY. ACCORDING TO THE PHYSICIAN THEY WERE INVESTIGATING ADVERSE EVENTS AND REQUESTED THAT THEIR LIGHT SOURCE BE INSPECTED. HE ASKED THAT THE AIR PRESSURE AND FLOW BE VERIFIED. THE PHYSICIAN REPORTED "POST-PROCEDURE DEVELOPMENT OF AIR EMBOLUS LEADING TO CEREBROVASCULAR COMPROMISE AND PERSISTENT NEUROLOGIC DYSFUNCTION AND/OR DEATH IN 2 ERCPS AND 1 EGD WITH ESOPHAGEAL BALLOON DILATION." THIS IS ONE OF THREE REPORTS, ALSO REFERENCE 241293-2012-00006 AND 241293-2012-00007. (B)(4) CHECKED THE PRESSURE AND AIR FLOW OF THE SUBJECT LIGHT SOURCE (X1-4400); SN: (B)(4)) AND SATISFACTORY RESULTS WERE OBTAINED. THE LIGHT SOURCE WAS ALLOWED TO RUN CONTINUOUSLY (5 HRS) AND HOURLY RESULTS WERE COLLECTED. THE LIGHT SOURCE WAS STABLE AND OPERATING WITHIN SPECIFICATION. A VISUAL INSPECTION OF THE LIGHT SOURCE NOTED SOME COSMETIC DEFECTS (MINOR SCRATCHES AND DENT) WHICH HAVE NO IMPACT ON THIS INCIDENT. THE LIGHT SOURCE WAS SOLD TO THE CUSTOMER ON (B)(4) 2010, TO DATE, NO REPAIR HAVE BEEN PERFORMED ON THE SUBJECT UNIT AND APPEARS TO REMAIN EQUIPPED WITH OEM PARTS. DUE TO THE AMOUNT OF TIME ELAPSED FROM WHEN THE PATIENT INCIDENT OCCURRED AND LIMITED INFORMATION AVAILABLE FROM THE CUSTOMER, THE ROOT CAUSE FOR THIS INCIDENT CANNOT BE DETERMINED. BASED ON (B)(4)'S INSPECTION RESULTS, NO EQUIPMENT MALFUNCTION COULD BE IDENTIFIED. THE LIGHT SOURCE HAD BEEN USED CLINICALLY SINCE THE INCIDENT ((B)(6) 2011) OCCURRED UNTIL THE LIGHT SOURCE WAS RETURNED TO (B)(4) ON (B)(4) 2012 FOR EVALUATION. IT WOULD APPEAR THAT THIS INCIDENT CAN EITHER BE ATTRIBUTED TO THE PATIENT'S CONDITION OR USER HANDLING. THIS REPORT IS BEING SUBMITTED AS MEDICAL DEVICE REPORT IN AN ABUNDANCE OF CAUTION.

Description of Event or Problem · 1

DURING A CUSTOMER VISIT, FUJIFILM'S FIELD ENGINEER WAS INFORMED OF AN ADVERSE EVENT. ACCORDING TO HOSPITAL STAFF, THE "PATIENT UNDERWENT AN EGD WITH ESOPHAGEAL DILATION FOR POST-GASTROTECTOMY STRICTURE; POST PROCEDURE, PT NOTED TO HAVE EXPERIENCED A CVA FROM AN AIR EMBOLISM." HE ALSO PROVIDED "NEUROLOGICAL DEFICITS FROM CVA; PT CONTINUES WITH REHABILITATION." THIS PATIENT IS NO LONGER AT THE FACILITY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 FUJINON LIGHT SOURCE EOQ FUJIFILM CORP. XL-4400

Patients

Seq Age Sex Outcome Treatment
1 51 YR Other