PULSE GEN MODEL 103
Report
- Report Number
- 1644487-2012-03237
- Event Type
- Injury
- Date Received
- December 7, 2012
- Date of Event
- November 12, 2012
- Report Date
- November 12, 2012
- Manufacturer
- CYBERONICS, INC.
- Product Code
- LYJ
- PMA / PMN Number
- P970003
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN, US
- Reporter Occupation
- PHYSICIAN
Narratives
.
ON (B)(6) 2012 IT WAS REPORTED THAT THE VNS PATIENT HAD 10-12 SEIZURES THAT MORNING, APPROXIMATELY 10 HEAD DROPS WITH LOSS OF ALL MUSCLE CONTROL WHICH WAS SOMETHING NEW, ONE FOCAL SEIZURE LASTING 3-4 MINUTES WHERE THE PATIENT COLLAPSED IN THE BATHROOM, AND ONE GRAND MAL LASTING 6 MINUTES. THE PATIENT CALLED 911 AND HAD SWIPED THE VNS MAGNET ABOUT 10 TIMES WHICH STOPPED THE FOCAL SEIZURE BUT NOT THE GRAND MAL SEIZURES. THE PATIENT WAS ALSO GIVEN 7.5MG DIASTAT AS HE DID NOT HAVE A 10MG PORTION AT THE HOUSE. THE PATIENT WAS NOTED TO HAVE BEEN ILL THE LAST 2-3 WEEKS WITH THE FLU AND THEN HAD VOMITING, BUT THE PATIENT STATED THAT THE LAST TIME HE WAS SICK WAS ON (B)(6) 2012 AND HE HAS NOT HAD ANY MISSED MEDICATIONS. THE PATIENT WAS NOW ALSO HAVING BRADYCARDIA. THE PHYSICIAN'S OFFICE LATER REPORTED THAT SINCE THE PATIENT WAS GIVEN DIASTAT DUE TO HIS INCREASE IN SEIZURES, THIS CAUSED THE BRADYCARDIA. DIASTAT CAUSED THE HEART RATE TO DROP; THE BRADYCARDIA WAS A SIDE EFFECT OF DIASTAT AND NOT RELATED TO VNS. ATTEMPTS FOR FURTHER INFORMATION FROM THE PHYSICIAN ARE UNDERWAY BUT NO ADDITIONAL INFORMATION HAS BEEN RECEIVED TO DATE.
ADDITIONAL INFORMATION WAS RECEIVED ON (B)(6) 2013 WHEN THE MANUFACTURER'S CONSULTANT STATED THAT THE ONLY INFORMATION THAT THE PHYSICIAN¿S OFFICE WAS ABLE TO PROVIDE WAS THAT THE INCIDENT WAS ON (B)(6) 2012 AND THE PATIENT WAS GIVEN ATIVAN AND DIASTAT WHICH IS WHAT CAUSED THE BRADYCARDIA. THE BRADYCARDIA DIDN'T HAVE ANYTHING TO VNS; IT WAS DUE TO THE PATIENT'S MEDICATION - DIASTAT AND ATIVAN. THE PATIENT'S SETTINGS WERE NOTED TO BE OUTPUT=1MA/FREQUENCY=20HZ/PULSE WIDTH=250USEC/ON TIME=30SEC/OFF TIME=5MIN/MAGNET OUTPUT=1.5MA/MAGNET ON TIME=60SEC/MAGNET PULSE WIDTH=250USEC AND THEN THE PATIENT CAME BACK IN ON (B)(6) 2012 AND THEY INCREASED THE OUTPUT CURRENT TO 1.25MA AND MAGNET OUTPUT TO 1.5MA, THE REST OF THE SETTINGS STAYED SAME. THE OFFICE AGAIN REITERATED THAT THE EVENT DID NOT HAVE ANYTHING TO DO WITH VNS. NO FURTHER INFORMATION WAS PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | PULSE GEN MODEL 103 | GENERATOR | LYJ | CYBERONICS, INC. | 103 | 3245 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 18 YR | Other |