UNKNOWN M2A CUP
Report
- Report Number
- 0001825034-2012-02424
- Event Type
- Injury
- Date Received
- November 15, 2012
- Date of Event
- June 23, 2006
- Report Date
- April 13, 2015
- Manufacturer
- BIOMET ORTHOPEDICS
- Product Code
- KWA
- PMA / PMN Number
- PUNKNOWN
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- ATTORNEY
Narratives
CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. THE FOLLOWING SECTIONS COULD NOT BE COMPLETED WITH THE LIMITED INFORMATION PROVIDED. EXPIRATION DATE - UNKNOWN. DATE IMPLANTED - UNKNOWN. MANUFACTURE DATE - UNKNOWN. THE PRODUCT IDENTIFICATION NECESSARY TO REVIEW MANUFACTURING HISTORY WAS NOT PROVIDED. THE REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 2 OF 2 MDRS FILED FOR THE SAME EVENT (REFERENCE 1825034-2012-01866-1 / 02424).
THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE ORIGINAL MEDWATCH. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THIS TYPE OF EVENT CAN OCCUR: UNDER WARNINGS IT STATES, "MALALIGNMENT OF THE COMPONENTS OR INACCURATE IMPLANTATION MAY LEAD TO EXCESSIVE WEAR AND/OR FAILURE OF THE IMPLANT OR PROCEDURE." UNDER POSSIBLE ADVERSE EFFECTS, NUMBER 1 STATES, "MATERIAL SENSITIVITY REACTIONS," AND "PARTICULATE WEAR DEBRIS AND DISCOLORATION FROM METALLIC AND POLYETHYLENE COMPONENTS OF JOINT IMPLANTS MAY BE PRESENT IN ADJACENT TISSUE OR FLUID." NUMBER 4 STATES, "LOOSENING OR MIGRATION OF THE IMPLANTS MAY OCCUR DUE TO LOSS OF FIXATION, TRAUMA, MALALIGNMENT, BONE RESORPTION, OR EXCESSIVE ACTIVITY." NUMBER 8 STATES, "DISLOCATION AND SUBLUXATION DUE TO INADEQUATE FIXATION AND IMPROPER POSITIONING." NUMBER 11 STATES, "WEAR AND/OR DEFORMATION OF ARTICULATING SURFACES." THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.
THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 2 OF 2 MDRS FILED FOR THE SAME EVENT (REFERENCE 1825034-2012-01866-2 & 02424-1).
LEGAL COUNSEL FOR THE PATIENT ALLEGES THAT PATIENT UNDERWENT TOTAL HIP ARTHROPLASTY AND REPORTS PATIENT ALLEGATIONS OF PERSONAL INJURY. ADDITIONAL INFORMATION PROVIDED IN OPERATIVE NOTES AND A REVIEW OF INVOICE HISTORY CONFIRMS THE INITIAL HIP ARTHROPLASTY PROCEDURE OCCURRED ON AN UNKNOWN DATE. SUBSEQUENTLY, PATIENT WAS REVISED ON (B)(6) 2006 DUE TO CUP MALPOSITIONING. A FURTHER REVISION WAS PERFORMED ON (B)(6) 2011 DUE TO CUP MALPOSITIONING. NO FURTHER INFORMATION HAS BEEN PROVIDED TO DATE. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.
LEGAL COUNSEL FOR THE PATIENT ALLEGES THAT PATIENT UNDERWENT TOTAL HIP ARTHROPLASTY AND REPORTS PATIENT ALLEGATIONS OF PERSONAL INJURY. ADDITIONAL INFORMATION PROVIDED IN OPERATIVE NOTES AND A REVIEW OF INVOICE HISTORY CONFIRMS THE INITIAL HIP ARTHROPLASTY PROCEDURE OCCURRED ON AN UNKNOWN DATE. SUBSEQUENTLY, PATIENT WAS REVISED ON (B)(6) 2006 ALLEGEDLY DUE TO CUP MALPOSITIONING. A FURTHER REVISION WAS PERFORMED ON (B)(6) 2011 DUE TO AN UNKNOWN REASON. NO FURTHER INFORMATION HAS BEEN PROVIDED TO DATE. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.
LEGAL COUNSEL FOR THE PATIENT ALLEGES THAT PATIENT UNDERWENT TOTAL HIP ARTHROPLASTY AND REPORTS PATIENT ALLEGATIONS OF PERSONAL INJURY. ADDITIONAL INFORMATION PROVIDED IN OPERATIVE NOTES AND A REVIEW OF INVOICE HISTORY CONFIRMS THE INITIAL HIP ARTHROPLASTY PROCEDURE OCCURRED ON AN UNKNOWN DATE. SUBSEQUENTLY, PATIENT WAS REVISED ON (B)(6) 2006 DUE TO CUP MALPOSITIONING. A FURTHER REVISION WAS PERFORMED ON (B)(6) 2011 DUE TO CUP MALPOSITIONING. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. ADDITIONAL INFORMATION RECEIVED IN PATIENT'S OPERATIVE REPORTS NOTES A REVISION OCCURRED ON (B)(6) 2006 DUE TO MALPOSITIONING OF ACETABULAR CUP. OPERATIVE REPORT FURTHER NOTED BROWNISH MATERIAL CONSISTENT WITH LOOSENING, WEAR OF THE CUP AND LINER SECONDARY TO SUBLUXATION DURING THE PROCEDURE. THE ACETABULAR CUP AND MODULAR HEAD WERE REPLACED. OPERATIVE REPORTS NOTED PATIENT UNDERWENT A FURTHER REVISION PROCEDURE ON (B)(6) 2011 DUE TO A LOOSE ACETABULAR CUP. OPERATIVE REPORT NOTED HIP CENTER MIGRATION, PERICAPSULAR ADHESIONS AND SCARRING AND WEAR AND MALPOSITIONING OF ACETABULAR CUP. THE MODULAR HEAD AND ACETABULAR CUP WERE REPLACED..
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | UNKNOWN M2A CUP | PROSTHESIS, HIP | KWA | BIOMET ORTHOPEDICS | N/A | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 56 YR | Hospitalization| R |