NOVASURE IMPEDANCE CONTROLLED EA SYSTEM
Report
- Report Number
- 1222780-2012-00238
- Event Type
- Injury
- Date Received
- November 7, 2012
- Date of Event
- October 8, 2012
- Report Date
- October 8, 2012
- Manufacturer
- HOLOGIC
- Product Code
- MNB
- PMA / PMN Number
- P010013
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NC, US
- Reporter Occupation
- PHYSICIAN
Narratives
LOT AND SERIAL NUMBER OF THE DISPOSABLE DEVICE NOT PROVIDED BY THE COMPLAINANT, THEREFORE THE EXPIRATION DATE IS NOT KNOWN. SERIAL NUMBER OF THE RADIO FREQUENCY CONTROLLER AND MYOSURE HYSTEROSCOPE NOT PROVIDED BY THE COMPLAINANT. THE DEVICE IS NOT BEING RETURNED THEREFORE, A FAILURE ANALYSIS OF THE COMPLAINT DEVICE CANNOT BE COMPLETED. LOT NUMBER OF THE DISPOSABLE DEVICE NOT PROVIDED BY THE COMPLAINANT, THEREFORE THE MANUFACTURE DATE IS NOT KNOWN. DEVICE HISTORY RECORD (DHR) REVIEW WAS UNABLE TO BE CONDUCTED FOR THE DISPOSABLE DEVICE AS THE LOT NUMBER WAS NOT PROVIDED BY THE COMPLAINANT. IFU, ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) WARNINGS: USE CAUTION NOT TO PERFORATE THE UTERINE WALL WHEN SOUNDING, DILATING, OR INSERTING THE DISPOSABLE DEVICE. IF THE DISPOSABLE DEVICE IS DIFFICULT TO INSERT INTO THE CERVICAL CANAL, USE CLINICAL JUDGMENT TO DETERMINE WHETHER OR NOT FURTHER DILATION IS REQUIRED. THE NOVASURE SYSTEM PERFORMS A CAVITY INTEGRITY ASSESSMENT (CIA) TEST TO EVAL THE INTEGRITY OF THE UTERINE CAVITY, AND SOUNDS AN ALARM WARNING OF A POSSIBLE PERFORATION PRIOR TO TREATMENT. (B)(4).
FOLLOWING A SUCCESSFUL MYOSURE PROCEDURE FOR UTERINE TISSUE REMOVAL, THE PHYSICIAN BEGAN A NOVASURE ENDOMETRIAL ABLATION. THE ABLATION WAS ABORTED AFTER A CAVITY INTEGRITY ASSESSMENT (CIA) TEST WAS UNSUCCESSFUL AND A HYSTEROSCOPY REVEALED A "VERY SMALL PERFORATION". NO TREATMENT WAS NEEDED FOR THE PERFORATION AND THE PT WAS DISCHARGED HOME. ON (B)(6) 2012, IT WAS REPORTED THE PT "IS DOING FINE." A DILATATION AND SOUNDING WITH A METAL SOUND (NOT HOLOGIC DEVICES) WERE PERFORMED PRIOR TO THE ATTEMPTED ABLATION. IT IS NOT KNOWN WHEN THIS PERFORATION OCCURRED OR WHAT INSTRUMENT MAY HAVE BEEN THE CAUSE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | NOVASURE IMPEDANCE CONTROLLED EA SYSTEM | MNB | HOLOGIC | NS2000 | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | UNK | Other | RADIO FREQUENCY CONTROLLER - SERIAL #UNK| MYOSURE HYSTEROSCOPE - SERIAL #UNK |