GORE EXCLUDER AAA ENDOPROSTHESIS
Report
- Report Number
- 2017233-2012-00699
- Event Type
- Injury
- Date Received
- October 11, 2012
- Date of Event
- June 16, 2011
- Report Date
- September 16, 2012
- Manufacturer
- W.L. GORE & ASSOCIATES
- Product Code
- MIH
- PMA / PMN Number
- P020004
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GR
- Reporter Occupation
- PHYSICIAN
Narratives
ADDITIONAL INFO REGARDING SPECIFIC LOT/SERIAL NUMBERS AND PT INFO WAS REQUESTED BUT NOT AVAILABLE. THEREFORE, NO ANALYSIS OR REVIEW OF THE MANUFACTURING RECORDS COULD BE PERFORMED. THE ARTICLE DOES NOT SPECIFY OR INDICATE; AND GORE WAS UNABLE TO DETERMINE WHICH EVENT, IF ANY, EVENT A GORE DEVICE MAY HAVE CAUSED OR CONTRIBUTED TO. THE INSTRUCTIONS FOR USE FOR THE GORE EXCLUDER AAA ENDOPROSTHESIS STATES: ADVERSE EVENTS THAT MAY OCCUR AND/OR REQUIRE INTERVENTION INCLUDE BUT ARE NOT LIMITED TO; ENDOPROSTHESIS: CLAUDICATION (E.G., BUTTOCK, LOWER LIMB). THE ARTICLE IDENTIFIED THE "MEAN PT AGE AND SEX TO BE A (B)(6) MALE.
AN ARTICLE PUBLISHED BY THE JOURNAL OF VASCULAR SURGERY, VOLUME 56, NUMBER 2 REVIEWED THE OUTCOMES OF ENDOVASCULAR REPAIR WITH SELECTIVE INTERNAL ILIAC ARTERY COVERAGE WITHOUT COIL EMBOLIZATION. KONSTANTINOS O. PAPAZOGLOU, MD, PHD, A GEORGE S. SFYROERAS, MD, PHD,B. NEOFYTOS ZAMBAS, MD, PHD, A KONSTANTINOS KONSTANTINIDIS, MD, PHD, A STAVROS K. KOKKOS, MD, PHDC AND MARIA MITKA, MD, (B)(6). IN REVIEW OF THE PUBLISHED LITERATURE THE FOLLOWING FINDINGS WERE NOTED: BETWEEN (B)(6) 1997 AND (B)(6) 2010, 137 PTS UNDERWENT ENDOVASCULAR ANEURYSM REPAIR (EVAR) OF THEIR ABDOMINAL AORTIC ANEURYSM (AAA) WHICH INCLUDED INTERNATIONAL COVERAGE OF THE INTERNAL ILIAC ARTERY (IIA). IN 112 PTS OF THE PTS THERE WAS NO EMBOLIZATION (NO EMBOLIZATION [NE] GROUP) OF THE IIA AND IN 25 PTS THE IIA WAS COIL EMBOLIZED (COIL EMBOLIZATION [CE] GROUP). COVERAGE OF THE IIA WAS BOTH UNILATERAL AND BI-LATERAL. ANATOMIC INDICATIONS FOR COVERAGE OF THE IIA WITHOUT COIL EMBOLIZATION INCLUDED PRESENCE OF ADEQUATE SEALING IN THE DISTAL 5 MM OF THE CIA, OR SEALING RING AT THE ORIGIN OF THE CIA, OR IIA DIAMETER <5 MM. PREOPERATIVE MEAN AAA SIZE WAS 60-14 MM, AND MEAN CIA DIAMETER WAS 38-13 MM. POSTOPERATIVE COMPUTED TOMOGRAPHY (CT) SCANNING WAS PERFORMED AT 1, 6, AND 12 MONTHS, AND YEARLY THEREAFTER. ((B)(6)). THE PTS WERE FOLLOWED UP FOR 33-30 MONTHS. THE ARTICLE SPECIFIES THE FOLLOWING STENT GRAFTS WERE IMPLANTED IN THE 137 PTS INVOLVED IN THIS STUDY: EXCLUDER (N 57), TALENT (N 53), ENDURANT (N 10), ANEURX (N 7), LIFEPATH (N 3), ENDOLOGIX (N 3), AND COOK ZENITH (N 1). THE ARTICLE DOES NOT SPECIFY WHICH DEVICE(S) ARE RELATED TO ANY INCIDENT REPORTED. THE RESULTS OF THE STUDY DEMONSTRATE THE ENDOVASCULAR TREATMENT OF AORTOILIAC ANEURYSMS WITHOUT COIL EMBOLIZATION OF THE IIA IS SAFE AND EFFECTIVE, IS ASSOCIATED WITH A LOW INCIDENCE OF POSTOPERATIVE COMPLICATIONS AND REINTERVENTIONS, AND HAS ACCEPTABLE MIDTERM RESULTS. THE ARTICLE REPORTS THAT 15 OF 37 PTS EXPERIENCED IMMEDIATE POSTOPERATIVE BUTTOCK CLAUDICATION. IF THREE OF 15 CASES BUTTOCK CLAUDICATION WAS SEVERE. NO DIFFERENCE IN THE SEVERITY OF BUTTOCK CLAUDICATION WAS NOTED BETWEEN THE TWO GROUPS. IN ALL PTS, BUTTOCK CLAUDICATION SIGNIFICANTLY AMELIORATED OR RESOLVED 6 MONTHS POSTOPERATIVELY. CLAUDICATION WAS CATEGORIZED AS SEVERE IF IT INTERFERED WITH THE PT'S DAILY ACTIVITIES, AND MILD IF THERE WAS MINIMAL IMPACT OF LIFESTYLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | GORE EXCLUDER AAA ENDOPROSTHESIS | MIH/SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | W.L. GORE & ASSOCIATES |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 71 YR | Other |