BABY CONTROL WALL MOUNT INFANT WARMER
Report
- Report Number
- 9611451-2012-00687
- Event Type
- Malfunction
- Date Received
- October 1, 2012
- Report Date
- September 3, 2012
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LTD
- Product Code
- FMT
- PMA / PMN Number
- K971461
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- OTHER
Narratives
(B)(4), SERIAL NUMBERS AND LOT DATE: (B)(4) 070130, (B)(4) - 070130, (B)(4) - 070130, (B)(4) - 070130, (B)(4) - 070130, (B)(4) - 070130. DEVICE MANUFACTURER DATE: 01/30/2007. METHOD: THE COMPLAINT WARMERS ARE NOT EXPECTED TO BE RETURNED TO THE MANUFACTURER FOR EVALUATION. OUR INVESTIGATION IS ACCORDINGLY BASED ON THE EVENT DESCRIPTION, PHOTOGRAPHS PROVIDED AND OUR KNOWLEDGE OF THE PRODUCT. RESULTS: INSPECTION OF THE PHOTOGRAPHS PROVIDED BY THE CUSTOMER REVEALED CRACKS ON THE DOME PORTION OF THE HEATER HEAD, CONFIRMING THE REPORTED FAULT. A LOT CHECK REVEALED ONE OTHER COMPLAINT OF THIS NATURE FOR THIS LOT NUMBER. CONCLUSION: IT IS LIKELY THAT THE FLAKING AND CRACKING OF THE COMPLAINT WARMER HEAD IS RELATED TO A KNOWN PROBLEM OF INCOMPATIBLE CLEANING SOLUTIONS REACTING WITH THE POLYCARBONATE PLASTIC AND ACRYLIC COMPONENTS OF THE INFANT WARMER. WHEN THE HEATER HEAD BEGINS TO WARM UP DURING USE, A CHEMICAL REACTION WITH THE INCOMPATIBLE CLEANING SOLUTION RESULTS IN GRADUAL CRACKING AND CRAZING OF THE HEATER HEAD THE INFANT WARMER SERVICE MANUAL FEATURES A DIAGRAM OF THE INFANT WARMER WHICH HIGHLIGHTS POLYCARBONATE AND ACRYLIC COMPONENTS AND STATES THE FOLLOWING: "CAUTION DO NOT CLEAN THE HIGHLIGHTED PLASTIC SURFACES WITH PROPRIETARY CLEANING PRODUCTS CONTAINING EITHER HYDROXIDES, HYPOCHLORITES, PEROXIDES, GLUTERALDEHYDE OR CLEANING PRODUCTS WITH A GREATER THAN 30% ALCOHOL BASE." "CAUTION THE CHEMICALS USED IN THESE PROPRIETARY CLEANING PRODUCTS MAY LEAD TO DISCOLOURATION, CRAZING AND EVENTUAL CRACKING OF THE HIGHLIGHTED PLASTIC SURFACES". AS PART OF CONTINUOUS IMPROVEMENT, WE HAVE SINCE REVISED OUR CLEANING INSTRUCTIONS TO RECOMMEND SPECIFIC PROPRIETARY CLEANING WIPES. A FISHER & PAYKEL HEALTHCARE REPRESENTATIVE HAS SINCE BEEN IN CONTACT WITH THE CUSTOMER AND PROVIDED GUIDELINES ON CLEANING THE PRODUCTS AS PER THE TECHNICAL MANUAL.
A HOSPITAL IN (B)(6) REPORTED THAT THE HEATER HEAD OF SIX BABY CONTROL WALL MOUNT INFANT WARMERS WERE CRACKED. NO PATIENT CONSEQUENCE WAS REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | BABY CONTROL WALL MOUNT INFANT WARMER | FMT | FMT | FISHER & PAYKEL HEALTHCARE LTD | IW980 | SEE H.10 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |