GLUMA DESENSITIZER (DEVICE 2)
Report
- Report Number
- 9610902-2012-00122
- Event Type
- Injury
- Date Received
- August 30, 2012
- Date of Event
- April 23, 2012
- Report Date
- August 3, 2012
- Manufacturer
- HERAEUS KULZER GMBH
- Product Code
- KLE
- PMA / PMN Number
- K962812
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AR, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
AS ALLOWED BY EXEMPTION #(B)(4), (B)(4) (THE IMPORTER) IS SUBMITTING THE REPORT ON BEHALF OF HERAEUS (B)(4) (THE MFR). ALTHOUGH WE HAVE NOT ESTABLISHED THAT THE DEVICE CAUSED OR CONTRIBUTED TO THE EVENT, WE'RE REPORTING IT OUT OF CAUTION TO BE COMPLIANT WITH 21 CFR PART 803. WE CANNOT RULE OUT CAUSALITY. CONCLUSION CODE, THE OFFICE STATED THEY, "APPLY THE GLUMA DESENSITIZER THEN BLOW IT OFF," AND THE DIRECTIONS FOR USE STATES, "LEAVE (GD) FOR 30-60 SECONDS. THEN DRY THE SURFACE CAREFULLY BY APPLYING A STREAM OF COMPRESSED AIR UNTIL THE FLUID FILM HAS DISAPPEARED AND THE SURFACE IS NO LONGER SHINY. THEN RINSE THOROUGHLY WITH WATER." THE OFFICE DID NOT FOLLOW THE DIRECTIONS WHEN USING THE GLUMA COMFORT BOND. EFFICACY CANNOT BE GUARANTEED WHEN THE DIRECTIONS ARE NOT FOLLOWED. THIS PRODUCT WAS NOT THE FOCUS OF THE COMPLAINT IT WAS ONLY MENTIONED AS BEING USED DURING THE OFFICES RESTORATIVE PROCESS AND WAS REPORTED TO MAINTAIN COMPLIANCE WITH 21 CFR PART 803.
RECEIVED COMPLAINT THAT OFFICE HAD RESTORATIONS COME OUT ON UP TO 12 PTS. THEY REPORTED USING 2 HERAEUS PRODUCTS DURING THE RESTORATIVE PROCEDURE. THEY HAD TREATMENT INFO ON 6 OF THE PTS. THIS IS THE SIXTH OF 14 REPORTS FOR DEVICE 2. ON (B)(4) 2012, DEALER REP CALLED TO RETURN THE GLUMA COMFORT BOND (GCB) BECAUSE HE SAID IT IS NOT BONDING PROPERLY. A MESSAGE WAS LEFT AT THE OFFICE TO FIND OUT WHAT NOT WORKING PROPERLY MEANT. ON (B)(4) 2012, A DENTAL ASSISTANT WAS CONTACTED AT THE OFFICE. SHE REPORTED THAT OVER THE LAST COUPLE OF MONTHS, THEY HAVE NOTICED ABOUT 10 OR 15 FILLINGS THAT HAVE POPPED OUT FROM THE ANTERIOR AND POSTERIOR AS WELL. SHE SAID THEY ETCH, RINSE, AND DRY. APPLY GLUMA DESENSITIZER AND BLOW IT OFF. THEY APPLY ONE COAT OF GCB, AIR DRY, LIGHT CURE FOR 10 SECONDS AND REPEAT. THEY USE PATTERSON BRAND FLOWABLE AND TETRIC CERAM COMPOSITE BY IVOCLAR. I EXPLAINED THAT WE RECOMMEND THE GLUMA DESENSITIZER BE USED WITH A RUBBER DAM, LEFT ON FOR 30-60 SECONDS AND RINSED UNDER SUCTION. THE GCB IS TO BE PLACED IN THREE COATS, LEFT TO DWELL FOR 15 SECONDS, APPLY LIGHT AIR FLOW TO EVAPORATE THE SOLVENT AND LIGHT CURED FOR 20 SECONDS. THEN SPOKE TO ANOTHER ASSISTANT. SHE WAS ASKED IF SHE KNEW WHICH PTS WERE INVOLVED. SHE SAID SHE DID. REQUESTED TO KNOW THE PTS, TREATMENT AREAS, TREATMENT DATES, AND DATES PT REPORTED DEBONDING TO THE OFFICE. SHE SAID SHE WOULD GET THIS INFO AND CALL BACK TOMORROW. ON (B)(4) 2012, SPOKE TO THE SECOND ASSISTANT. SHE SAID THAT SHE REMEMBERED SIX OF THE PTS AND BELIEVES THERE MAY BE 2 TO 6 MORE. ON PT #5, THEY TREATED TOOTH NUMBER #9MI ON (B)(6) 2010. THE RESTORATION CAME OUT ON (B)(6) 2012 AND WAS REPLACED THAT DAY. ON (B)(4) 2012, SPOKE TO THE FIRST ASSISTANT. ASKED HOW THE PTS WERE DOING. SHE SAID THEY WERE FINE AND THE FILLINGS DID NOT COME OUT. SHE SAID THEY DID NOT USE THE GCB TO BOND THE REPLACEMENT FILLINGS SHE SAID THAT THEY USED FUTURA BOND BY VOCO AND THAT THEY HAVE SWITCHED. I ASKED IF THE DENTIST HAS TRIED THE REPLACEMENT GCG THAT WAS SENT. SHE SAID HE HAS NOT. SHE SAID THAT THEY HAVE BEEN CONTACTED 3 TIMES ABOUT THIS AND ASKED WHY. I TOLD THAT WE LIKE TO F/U ON THE PT STATUS. SHE SAID THAT WAS NICE, BUT THAT THEY DID NOT WANT TO BE CONTACTED ANYMORE ABOUT THIS SITUATION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | GLUMA DESENSITIZER (DEVICE 2) | KLE AGENT, TOOTH BONDING, RESIN | KLE | HERAEUS KULZER GMBH |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 87 YR | Required Intervention |