TISSOMAT AND SPRAY SET
Report
- Report Number
- 2954761-2012-00024
- Event Type
- Injury
- Date Received
- June 29, 2012
- Date of Event
- June 1, 1990
- Report Date
- June 14, 2012
- Manufacturer
- BAXTER HEALTHCARE - VIENNA
- Product Code
- FMF
- PMA / PMN Number
- K981089
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). BAXTER MEDICAL ASSESSMENT: THIS IS AN ADVERSE EVENT REPORTED IN AN ARTICLE WRITTEN BY LANGE ETAL PUBLISHED IN 1990 WHICH CLEARLY DESCRIBES THE USE OF THE GAS REGULATOR (TISSOMAT) IN COMBINATION WITH A FOUR LUMEN SPRAY APPLICATION CATHETER TO DELIVER TISSEEL FIBRIN SEALANT THROUGH AN ABNORMAL CHANNEL (FISTULA). THIS FOUR LUMEN SPRAY APPLICATION CATHETER WAS SUBSEQUENTLY REMOVED FROM THE GLOBAL MARKET IN 1990. THE USE OF THIS NARROW DIAMETER, LONG CATHETER TO DELIVER FIBRIN SEALANT IN CONJUNCTION WITH COMPRESSED GAS LEAD TO PERSISTENT PNEUMOPERITONEUM (GAS ENTRAPMENT) WHICH REQUIRED DEFLATION VIA PERCUTANEOUS PUNCTURE. THE USE OF THE TISSOMAT WITH THE CURRENTLY APPROVED SPRAY SET DOES NOT CARRY THE SAME RISK. THE SPRAY SET INSTRUCTIONS FOR USE CLEARLY STATE TO KEEP BETWEEN THE SPRAY HEAD TIP 10 - 20CM AWAY FROM THE TISSUE AND THE LENGTH OF THE SPRAY HEAD DOES NOT ALLOW FOR INSERTION INTO A NARROW CHANNEL OR CAVITY. THE SPRAY CATHETER WHICH ALLOWED APPLICATION INTO A VERY NARROW ORIFICE WAS THE CAUSE OF THIS EVENT. THE TISSOMAT GAS REGULATOR WHILE A CONTRIBUTING FACTOR IS NOT INDICATED FOR USE WITH ANY OTHER APPLICATORS OTHER THAN THE SPRAY SETS WHICH DO NOT ALLOW FOR APPLICATION IN SMALL CAVITIES NO FURTHER ACTION IS REQUIRED.
FROM LITERATURE: V. LANGE, G. MEYER, H. WENK, AND F.W. SCHILDBERG. FISTULOSCOPY ? AN ADJUVANT TECHNIQUE FOR SEALING GASTROINTESTINAL FISTULAE (1990). SURGICAL ENDOSCOPY. 1990; 4: 212-216 PATIENT (B)(6), A (B)(6) MAN WITH NECROTIZING PANCREATITIS, PERFORATION OF THE DUODENAL BULB AND ABSCESS FORMATION, UNDERWENT A BILLROTH II GASTRECTOMY (ROUX-EN Y ANASTOMOSIS), CHOLECYSTECTOMY, AND DEBRIDEMENT OF PANCREATIC NECROSIS. THE POST-OPERATIVE COURSE WAS UNEVENTFUL UNTIL THE 6TH DAY WHEN PURULENT MATERIAL DRAINED FROM THE ROBINSON CATHETER PLACED BETWEEN THE GASTROJEJUNOSTOMY AND THE PANCREAS. A FISTULOGRAM DEMONSTRATED A BRANCHED FISTULA AROUND THE PANCREAS WITH A CONNECTION TO THE GASTRIC ANASTOMOSIS AND TO THE LEFT COLON. FIBRIN SEALING OF THE SMALL DEFECT IN THE GASTRIC ANASTOMOSIS DID NOT STOP THE PURULENT OUTFLOW. THEREFORE, A SECOND ATTEMPT WAS CARRIED OUT AFTER A TOTAL OF 25 DAYS CONSERVATIVE TREATMENT. THE GASTRIC LEAKAGE WAS AGAIN OCCLUDED BY FIBRIN. THE FISTULA OPENING IN THE COLON COULD NOT BE EXPOSED, ALTHOUGH PUS WAS VISIBLE IN THE BOWEL LUMEN. UNDER FLUOROSCOPIC CONTROL, A BRONCHOSCOPE WAS INTRODUCED INTO THE FISTULA AND POSITIONED AS CLOSE AS POSSIBLE TO THE COLON, WHERE A COLONOSCOPE WAS HELD IN FRONT OF THE SUSPECTED OPENING FISTULA. EIGHTY MILLIGRAMS OF GENTAMICIN WAS INSTILLED VIA THE BRONCHOSCOPE, AND WHEN WITHDRAWING THE INSTRUMENT 10 ML FIBRIN GLUE WAS SPRAYED INTO THE FISTULA. THE REMAINING FISTULA TRACTS WERE FILLED WITH 20 ML PROLAMIN INTRODUCED THROUGH THE OPENING IN THE SKIN. IN THE FOLLOWING DAYS, THERE WAS NO DRAINAGE FROM THE FISTULA AND THE PATIENT REMAINED AFEBRILE. A PERSISTING PNEUMOPERITONEUM DEVELOPED AND WAS RELATED TO THE GAS-JET APPLICATION BY THE TISSOMAT USED TO OBTAIN A BETTER VIEW DURING FISTULOSCOPY. THIS NECESSITATED DEFLATION OF THE ABDOMEN BY PERCUTANEOUS PUNCTURE. ORAL NUTRITION WAS ALLOWED ON THE 4TH DAY, AND THE PATIENT WAS DISCHARGED, CURED, 1 WEEK LATER. THE PATIENT WAS SYMPTOM-FREE AND COMPLETELY RECOVERED AT THE 3-MONTH FOLLOW-UP. NO ADDITIONAL INFORMATION IS AVAILABLE ON THE CASE AND DUE TO THE AGE OF THE PUBLICATION NO FOLLOW-UP WILL BE MADE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | TISSOMAT AND SPRAY SET | SYRINGE, PISTON | FMF | BAXTER HEALTHCARE - VIENNA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 66 | Other |