FDA Adverse Event Injury Summary report: N

IMPELLA

MDR report key: 25315316 · Received May 28, 2026

Report

Report Number
1220648-2026-08203
Event Type
Injury
Date Received
May 28, 2026
Date of Event
May 21, 2026
Manufacturer
ABIOMED, INC. - 1220648
Product Code
OZD
UDI-DI
00813502012279
PMA / PMN Number
P140003
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AZ, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

A4 WEIGHT IS UNKNOWN THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ABIOMED INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ABIOMED INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. RELATED MEDICAL DEVICE REPORTS: THIS IMPELLA CP DEVICE REPORT IS ONE OF TWO DEVICES ASSOCIATED WITH THE EVENT. REFER TO THE RELATED MANUFACTURER REPORT NUMBER AS NOTED IN SECTION H10 FOR THE MEDICAL DEVICE REPORT ON THE IMPELLA PURGE CASSETTE.

Description of Event or Problem · 0

CLINICAL NARRATIVE: AN IMPELLA CP DEVICE WAS INSERTED VIA THE RIGHT FEMORAL ARTERY IN A 77-YEAR-OLD MALE PATIENT PRESENTING WITH HIGH-RISK PERCUTANEOUS CORONARY INTERVENTION (HRPCI). THE PATIENT HAD A HISTORY OF KNOWN CORONARY ARTERY DISEASE. THE PATIENT¿S CLINICAL STATE PRIOR TO INITIATION OF SUPPORT WAS IDENTIFIED AS SCAI SHOCK STAGE A. THE PHYSICIAN FLUSHED THE INTRODUCER PRIOR TO INSERTING THE IMPELLA, WITH AN ACT OF 261. THE IMPELLA CROSSED THE AORTIC VALVE WITHOUT ISSUE. AFTER REMOVING THE WIRE AND TURNING THE IMPELLA ON, A HIGH PURGE FLOW ALARM WAS TRIGGERED, WITH A PURGE FLOW OF 30¿ML/HR. THE LINE WAS ASSESSED AND NO KINKS WERE IDENTIFIED. THE PHYSICIAN DECIDED TO REMOVE THE PUMP AND CASSETTE AND REPLACE THEM WITH A SECOND IMPELLA CP. THE IMPELLA CP DEVICE WAS EXCHANGED FOR ANOTHER IMPELLA CP WITHOUT ANY OBSERVED IMPACT ON THE PATIENT¿S HEMODYNAMIC STATUS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
163976 IMPELLA TEMPORARY NON-ROLLER TYPE LEFT HEART SUPPORT BLOOD PUMP OZD ABIOMED, INC. - 1220648 2027822346 00813502012279

Patients

Seq Age Sex Outcome Treatment
1 77 YR Male Required Intervention