WAVEWRITER ALPHA?
Report
- Report Number
- 3006630150-2026-03253
- Event Type
- Injury
- Date Received
- May 19, 2026
- Date of Event
- April 21, 2026
- Report Date
- May 18, 2026
- Manufacturer
- BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
- Product Code
- LGW
- UDI-DI
- 08714729985099
- PMA / PMN Number
- P030017
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THE DEVICE WAS NOT RETURNED FOR ANALYSIS; THEREFORE, A TECHNICAL ANALYSIS COULD NOT BE PERFORMED. IT WAS CONFIRMED THESE DEVICES MET MANUFACTURING SPECIFICATION PRIOR TO DISTRIBUTION AND THERE WERE NO MANUFACTURING DEVIATIONS WHICH COULD HAVE CONTRIBUTED TO THE REPORTED EVENT. REVIEW OF THE INSTRUCTIONS FOR USE (IFU) CONFIRMED THERE WAS RELEVANT CONTENT AND SUFFICIENT GUIDANCE WITH RESPECT TO THE CIRCUMSTANCES DESCRIBED WITHIN THIS COMPLAINT. NO UPDATES ARE REQUIRED TO THE IFU AS A RESULT OF THIS EVENT. BASED ON A THOROUGH REVIEW OF THE REPORTED COMPLAINT, BOSTON SCIENTIFIC HAS ASSIGNED AN INVESTIGATION CONCLUSION CODE OF CAUSE NOT ESTABLISHED BLOCK B3: APPROXIMATED BASED ON THE DATE THE MANUFACTURER BECAME AWARE OF THE EVENT. ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED IN THE EVENT: MODEL NUMBER/CATALOG NUMBER: SC-2317-50. SERIAL NUMBER: (B)(6). BATCH/LOT NUMBER: (B)(6). MODEL/CATALOG DESCRIPTION: INFINION CX LEAD KIT, 50CM. UNIQUE IDENTIFIER (UDI) #: (B)(4). MODEL NUMBER/CATALOG NUMBER: SC-2317-50. BATCH/LOT NUMBER: (B)(6). SERIAL NUMBER: (B)(6). MODEL/CATALOG DESCRIPTION: INFINION CX LEAD KIT, 50CM. UNIQUE IDENTIFIER (UDI) #: (B)(4). *INCLUDE MFR NARRATIVE PI-DONE (B)(6) 2026*.
BLOCK B3: APPROXIMATED BASED ON THE DATE THE MANUFACTURER BECAME AWARE OF THE EVENT. ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED IN THE EVENT: MODEL NUMBER/CATALOG NUMBER: SC-2317-50, SERIAL NUMBER: (B)(6), BATCH/LOT NUMBER: 7075966, MODEL/CATALOG DESCRIPTION: INFINION CX LEAD KIT, 50 CM, UNIQUE IDENTIFIER (UDI) #: (B)(4). MODEL NUMBER/CATALOG NUMBER: SC-2317-50, BATCH/LOT NUMBER: 5143614, SERIAL NUMBER: (B)(6), MODEL/CATALOG DESCRIPTION: INFINION CX LEAD KIT, 50 CM, UNIQUE IDENTIFIER (UDI) #: (B)(4).
IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING INADEQUATE PAIN RELIEF. THE PATIENT UNDERWENT A SPINAL CORD STIMULATOR (SCS) SYSTEM EXPLANT PROCEDURE. NO FURTHER INFORMATION HAS BEEN OBTAINED DESPITE GOOD FAITH EFFORTS.
IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING INADEQUATE PAIN RELIEF. THE PATIENT UNDERWENT A SPINAL CORD STIMULATOR (SCS) SYSTEM EXPLANT PROCEDURE. NO FURTHER INFORMATION HAS BEEN OBTAINED DESPITE GOOD FAITH EFFORTS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 116041 | WAVEWRITER ALPHA? | STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF | LGW | BOSTON SCIENTIFIC NEUROMODULATION CORPORATION | SC-1232 | 520032 | 08714729985099 |