FDA Adverse Event Malfunction Summary report: N

BREATHING CIRCUIT SET

MDR report key: 25135673 · Received May 11, 2026

Report

Report Number
3001421318-2026-00294
Event Type
Malfunction
Date Received
May 11, 2026
Date of Event
April 30, 2026
Report Date
May 11, 2026
Manufacturer
HAMILTON MEDICAL AG
Product Code
BZO
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
EI
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

HAMILTON MEDICAL AG REFERENCE NUMBER: (B)(4). INVESTIGATION IS ONGOING.

Description of Event or Problem · 0

IT WAS REPORTED TO HAMILTON MEDICAL AG, THAT: ON (B)(6) 2026, A HAMILTON-T1 VENTILATOR (PN 161006 / SN (B)(6) AND A BREATHING CIRCUIT SET (PN UNKNOWN / LN UNKNOWN) PASSED PRE-OPERATIONAL SAFETY CHECKS BUT FAILED TO VENTILATE THE PATIENT SCHEDULED FOR A CT SCAN. ONCE CONNECTED TO THE PATIENT FOR VENTILATION, A MESSAGE READING "OBSTRUCTION" APPEARED. EVENTUALLY IT FUNCTIONED ON VC VENTILATION MODE. THE SAME ISSUE OCCURRED WITH THE SAME PATIENT BUT A SECOND HAMILTON VENTILATOR DOWN IN THE CT SCANNER, WITH THE TUBING CHANGED TWICE. THE PATIENT WAS THEN PLACED BACK ON A SERVO VENTILATOR WITH NO ISSUES. A 45-MINUTE DELAY TO THE CT SCAN WAS REPORTED. PATIENT INVOLVEMENT WITH MEDICAL INTERVENTION AND NO PATIENT, USER OR THIRD PARTY HARM WAS REPORTED. FOR THIS SPECIFIC CASE, LOGFILES FOR THE HAMILTON-T1 VENTILATOR WERE PROVIDED: LINE 70: 60/2026-04-30 17:17:19/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 72: 62/2026-04-30 17:17:11/!!! /EXHALATION OBSTRUCTED LINE 74: 64/2026-04-30 17:17:05/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 77: 67/2026-04-30 17:16:57/!!! /EXHALATION OBSTRUCTED LINE 79: 69/2026-04-30 17:16:48/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 81: 71/2026-04-30 17:16:41/!!! /EXHALATION OBSTRUCTED LINE 83: 73/2026-04-30 17:16:35/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 85: 75/2026-04-30 17:16:27/!!! /EXHALATION OBSTRUCTED LINE 87: 77/2026-04-30 17:16:21/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 90: 80/2026-04-30 17:16:13/!!! /EXHALATION OBSTRUCTED LINE 150: 140/2026-04-30 17:14:17/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 151: 141/2026-04-30 17:14:09/!!! /EXHALATION OBSTRUCTED LINE 153: 143/2026-04-30 17:14:00/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 156: 146/2026-04-30 17:13:52/!!! /EXHALATION OBSTRUCTED LINE 159: 149/2026-04-30 17:13:46/!!! /EXHALATION OBSTRUCTED CONDITION REMOVED LINE 162: 152/2026-04-30 17:13:38/!!! /EXHALATION OBSTRUCTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
42811 BREATHING CIRCUIT SET BREATHING CIRCUIT SET BZO HAMILTON MEDICAL AG UNKNOWN UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1