FDA Adverse Event Malfunction Summary report: N

THERMOCOOL SMARTTOUCH SF

MDR report key: 24904915 · Received April 16, 2026

Report

Report Number
2029046-2026-01244
Event Type
Malfunction
Date Received
April 16, 2026
Date of Event
February 8, 2026
Report Date
April 16, 2026
Manufacturer
BIOSENSE WEBSTER INC
Product Code
LPB
UDI-DI
10846835009804
PMA / PMN Number
P030031/S078
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

THE ¿SUSPECTED MEDICAL DEVICE¿ REPORTED IN SECTION D OF THIS REPORT IS NOT MARKETED IN USA OR APPROVED BY THE FDA. HOWEVER, IT IS BEING REPORTED AS BIOSENSE WEBSTER CONSIDERS THIS AS A SIMILAR DEVICE TO THERMOCOOL SMARTTOUCH SF CATHETER APPROVED UNDER P030031/S078. THE PRODUCT INVESTIGATION WAS COMPLETED. DEVICE EVALUATION DETAILS: THE DEVICE WAS RETURNED TO JOHNSON & JOHNSON MEDTECH (J&J MEDTECH) FOR EVALUATION. FOLLOWING J&J MEDTECH PROCEDURES, A VISUAL INSPECTION AND TEMPERATURE AND IMPEDANCE TEST OF THE RETURNED DEVICE WERE PERFORMED. VISUAL ANALYSIS REVEALED REDDISH BROWN MATERIAL INSIDE THE PEBAX AND A SEPARATION BETWEEN PEBAX AND ELECTRODE SECTION. A TEMPERATURE AND IMPEDANCE TEST WAS PERFORMED AND NO TEMPERATURE VALUES WERE DISPLAYED. THE THERMOCOUPLE CONTINUITY WAS MEASURED, AND THE RESULTS WERE FOUND WITHIN SPECIFICATIONS. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE 31606488L NUMBER, AND NO INTERNAL ACTIONS RELATED TO THE REPORTED COMPLAINT CONDITION WERE IDENTIFIED. THE REDDISH MATERIAL INSIDE THE PEBAX COULD BE RELATED TO THE TEMPERATURE SENSOR ISSUE REPORTED BY THE CUSTOMER; THEREFORE, THE CUSTOMER COMPLAINT WAS CONFIRMED. THE ROOT CAUSE OF THE PEBAX DAMAGE IS TRACED TO THE MANUFACTURING PROCESS. THE INSTRUCTIONS FOR USE (IFU) CONTAIN THE FOLLOWING RECOMMENDATIONS: WHEN CLEANING THE TIP ELECTRODE, BE CAREFUL NOT TO TWIST THE TIP ELECTRODE WITH RESPECT TO THE CATHETER SHAFT; TWISTING MAY DAMAGE THE TIP ELECTRODE BOND AND LOOSEN THE TIP ELECTRODE, OR MAY DAMAGE THE CONTACT FORCE SENSOR. A SIGNIFICANT CHANGE IN THE BASELINE READING AFTER CLEANING MIGHT INDICATE A DAMAGED CONTACT FORCE SENSOR. IN ADDITION, IN ORDER TO PREVENT DAMAGE TO THE CATHETER TIP, VERIFY COMPATIBILITY BETWEEN THE SHEATH AND CATHETER, ADVANCE THE CATHETER THROUGH THE SHEATH PRIOR TO INSERTION. ANY SHEATH < 8.5 F IS CONTRAINDICATED. THIS PRODUCT ISSUE WILL BE ADDRESSED THROUGH THE QUALITY SYSTEM. AN INTERNAL ACTION WAS CREATED FOR FURTHER INVESTIGATION OF THE FORCE SENSOR SLEEVE INSOLATION TO PREVENT FLUIDS TO GET INSIDE INTO THE DEVICE. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REFERENCE NUMBER: (B)(4).

Description of Event or Problem · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION - PAROXYSMAL ABLATION PROCEDURE WITH A THERMOCOOL SMARTTOUCH SF CATHETER AND POST PROCEDURE THE BWI PRODUCT ANALYSIS LAB SEPARATION BETWEEN THE PEBAX AND ELECTRODE SECTION. DURING THE PROCEDURE ITSELF, THERE WAS NO TEMPERATURE DISPLAYED ON THE CARTO OR GENERATOR. A SECOND DEVICE WAS USED TO COMPLETE THE OPERATION. THERE WAS NO ADVERSE EVENT REPORTED ON PATIENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
961917 THERMOCOOL SMARTTOUCH SF CARDIAC ABLATION PERCUTANEOUS CATHETER LPB BIOSENSE WEBSTER INC 31606488L 10846835009804

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown