MITRACLIP® SYSTEM CLIP DELIVERY SYSTEM
Report
- Report Number
- 2135147-2026-02443
- Event Type
- Death
- Date Received
- April 14, 2026
- Date of Event
- March 19, 2026
- Report Date
- May 27, 2026
- Manufacturer
- ABBOTT MEDICAL
- Product Code
- NKM
- PMA / PMN Number
- P100009
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THE DEVICE WILL NOT BE RETURNED FOR EVALUATION. INVESTIGATION IS NOT YET COMPLETE. A FOLLOW-UP REPORT WILL BE SUBMITTED WITH ALL ADDITIONAL RELEVANT INFORMATION.
THE DEVICE WAS NOT RETURNED FOR ANALYSIS. THE LOT HISTORY RECORD (LHR) AND COMPLAINT HISTORY REVIEW WAS NOT PERFORMED BECAUSE THIS INCIDENT WAS BASED ON AN ARTICLE REVIEW AND NO LOT INFORMATION WAS PROVIDED. BASED ON AVAILABLE INFORMATION AND THE LIMITED INFORMATION AVAILABLE FROM THE ARTICLE, THE CAUSE OF THE DIFFICULT LEAFLET CAPTURE, TISSUE INJURY, AND DEATH WERE UNABLE TO BE DETERMINED. THE REPORTED EMBOLISM APPEARS TO BE RELATED TO THE REPORTED TISSUE INJURY. THE REPORTED EKG/ECG CHANGES WERE LIKELY RELATED TO THE REPORTED EMBOLISM. THE REPORTED PATIENT EFFECTS OF DEATH, TISSUE INJURY, EMBOLISM, AND EKG/ECG CHANGES AS LISTED IN THE MITRACLIP SYSTEM INSTRUCTIONS FOR USE, ARE KNOWN POSSIBLE COMPLICATIONS ASSOCIATED WITH MITRACLIP PROCEDURES. THE REPORTED UNEXPECTED MEDICAL WAS THE RESULT OF CASE-SPECIFIC CIRCUMSTANCES. THERE IS NO INDICATION OF A PRODUCT ISSUE WITH RESPECT TO MANUFACTURE, DESIGN, OR LABELING.
THE ARTICLE, "MITRAL LEAFLET FRAGMENT EMBOLIZATION CAUSING CORONARY OCCLUSION DURING RESCUE TRANSCATHETER MITRAL VALVE REPAIR FOR ACUTE MITRAL REGURGITATION", WAS REVIEWED. THE ARTICLE PRESENTED A CASE STUDY OF A 77-YEAR-OLD FEMALE PATIENT WITH DYSPNEA, RESPIRATORY DISTRESS, CYANOSIS, ORTHOPNEA, HYPOXEMIA, HOLOSYSTOLIC APICAL MURMUR AND DIFFUSE PULMONARY RALES, POSTERIOR LEAFLET FLAIL, AND SEVERE MITRAL REGURGITATION. ON AN UNKNOWN DATE, A MITRACLIP PROCEDURE WAS PERFORMED TO TREAT MITRAL REGURGITATION (MR). AN XTW CLIP WAS INSERTED AND GRASPING WAS PERFORMED. WHILE CLOSING THE ARM, THE POSTERIOR LEAFLET DISAPPEARED FROM BETWEEN THE CLIP ARMS AND GRIPPERS. THE CLIP WAS THEN REPOSITIONED AND GRASPING WAS PERFORMED AGAIN. HOWEVER, ST ELEVATION WAS OBSERVED. EMERGENT CORONARY ANGIOGRAPHY SHOWED ACUTE COMPLETE OCCLUSION OF THE RIGHT CORONARY ARTERY. A BALLOON ANGIOPLASTY RESTORED ANTEGRADE FLOW. DUE TO THE CLIPPING OF THE A3-P3 SEGMENT, GRASPING REMAINED UNACHIEVABLE AND SEVERE MR REMAINED. THE PATIENT'S CONDITION CONTINUED TO DETERIORATE, AND THE PATIENT DIED ON HOSPITAL DAY 4. AUTOPSY SHOWED MULTIPLE EVENLY SPACED PERFORATIONS CONSISTENT WITH PENETRATION BY THE GRIPPERS. HISTOPATHOLOGY OF THE RCA OBSTRUCTION REVEALED AN EMBOLUS COMPOSED OF TISSUE. [THE PRIMARY AND CORRESPONDING AUTHOR WAS YASUHIDE MOCHIZUKI, DIVISION OF CARDIOLOGY, DEPARTMENT OF MEDICINE, SHOWA MEDICAL UNIVERSITY SCHOOL OF MEDICINE, TOKYO, JAPAN, WITH CORRESPONDING EMAIL: [email protected]].
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 541799 | MITRACLIP® SYSTEM CLIP DELIVERY SYSTEM | VALVE REPAIR | NKM | ABBOTT MEDICAL | UNK CDS |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |