- Report Number
- 2015691-2026-14089
- Event Type
- Malfunction
- Date Received
- April 11, 2026
- Date of Event
- March 20, 2026
- Report Date
- May 14, 2026
- Manufacturer
- EDWARDS LIFESCIENCES, PR
- Product Code
- DYG
- PMA / PMN Number
- K160084
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MI, US
- Reporter Occupation
- 003
Narratives
THE DEVICE EVALUATION IS ANTICIPATED. A SUPPLEMENTAL REPORT WILL BE FORTHCOMING WHEN THE INVESTIGATION IS COMPLETED. A DEVICE HISTORY RECORD REVIEW WAS UNABLE TO BE COMPLETED AS THE LOT NUMBER IS UNKNOWN. BECAUSE THE LOT NUMBER IS UNKNOWN, THE FULL UDI NUMBER IS NOT AVAILABLE. THE PRIMARY DEVICE IDENTIFIER (DI) NUMBER WAS NOT PROVIDED. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS A PART OF THE MONTHLY REVIEW. D2B: ADDITIONAL DEVICE PRODUCT CODE: DQO, DXN, DQE, KRA, DQK, DRS, DSB, QAQ.
THERE WAS NO PRODUCT EVALUATION AS AFFECTED UNIT WAS NOT RETURNED; THEREFORE, A PRODUCT NON-CONFORMANCE OR DEVICE FAILURE COULD NOT BE CONFIRMED. COMPLAINTS INCIDENCE FOR BLOOD CLOTS WILL CONTINUE TO BE MONITORED, AND APPLICABLE ACTIONS WILL BE TAKEN AS REQUIRED. AN ENGINEERING EVALUATION WAS INITIATED TO ASSESS FOR ANY MANUFACTURING RELATED PROCESSES WHICH COULD BE CORRELATED TO THE COMPLAINT. WITHOUT RETURN OF THE DEVICE, A ROOT CAUSE COULD NOT BE DETERMINED. AS PART OF THE MANUFACTURING PROCESS 100% OF THE UNITS GO THROUGH FLOW AND LEAK TEST INSPECTION. THE LOT NUMBER WAS NOT PROVIDED THUS A DEVICE HISTORY RECORD WAS NOT REVIEWED.
IT WAS REPORTED THAT POST PROCEDURE THE SWAN-GANZ CCOMBO V HAD CLOTTING ISSUES. ON (B)(6), THE PATIENT HAD THE FIRST SWAN-GANZ, WHICH CLOTTED IMMEDIATELY UPON PATIENT RETURNING FROM THE CCL. THE SECOND SWAN-GANZ WAS PLACED ON THE SAME DAY (B)(6) AROUND 3PM. THIS CATHETER THEN CLOTTED LATER IN THE EVENING. THE PATIENT NEEDED MONITORING, DECISION WAS MADE TO INSTILL CATH FLO WHICH DID WORK BUT THEN CLOTTED ON (B)(6). SWAN-GANZ WAS REMOVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 119315 | SWAN-GANZ CCOMBO V | CATHETER, FLOW DIRECTED | DYG | EDWARDS LIFESCIENCES, PR | 777F8 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |