FDA Adverse Event Malfunction Summary report: N

QUICK SET

MDR report key: 24711525 · Received March 30, 2026

Report

Report Number
3003442380-2026-99744
Event Type
Malfunction
Date Received
March 30, 2026
Date of Event
February 21, 2024
Report Date
February 25, 2026
Manufacturer
UNOMEDICAL DEVICES S.A. DE C.V.
Product Code
FPA
UDI-DI
05705244017450
PMA / PMN Number
K160648
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

UNOMEDICAL HEREBY SUBMITS THIS INITIAL REPORT AS PART OF ITS COMPLAINT REMEDIATION ACTIVITIES CONDUCTED UNDER A CORRECTIVE AND PREVENTIVE ACTION (CAPA)/FDA ACTION PLAN. THIS SUBMISSION INCLUDES A RETROSPECTIVE REASSESSMENT OF PREVIOUSLY EVALUATED COMPLAINTS. UNOMEDICAL IS PROVIDING THIS INITIAL INFORMATION IN ACCORDANCE WITH THE REPORTING REQUIREMENTS SET FORTH IN 21 CFR PART 803. ANY FIELDS LEFT BLANK INDICATE THAT THE INFORMATION IS UNKNOWN, UNAVAILABLE, OR REMAINS UNCHANGED BASED ON THE REVIEW COMPLETED ON 25-FEB-2026 AND INVESTIGATION COMPLETED ON 05-MAR-2026 THIS MEDICAL DEVICE REPORT (MDR) IS BEING SUBMITTED AS THE INITIAL REPORT. ADDITIONAL INFORMATION - THIS MDR IS BEING SUBMITTED TO INCLUDE THE BELOW: H6: INVESTIGATION RESULTS UNDER TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS. THE REFERENCE SAMPLES WERE VISUALLY INSPECTED AND TESTED FOR CLICK AND STATIC PULL BASE-CONNECTOR. ALL TEST RESULTS WERE WITHIN SPECIFICATIONS. THE BATCH RECORD 6001974 WAS VERIFIED AND IT WAS FOUND WITHIN SPECIFICATIONS. THIS INVESTIGATION HAS BEEN UPDATED BECAUSE THE MALFUNCTION CODE CHANGED, WHICH REQUIRES ADDITIONAL ACTIVITIES NOT INCLUDED IN THE ORIGINAL INVESTIGATION DATED 26-FEB 2024. THE ORIGINAL INVESTIGATION REMAINS VALID AND HAS NOT BEEN MODIFIED. AS PART OF THIS REASSESSMENT, THE FOLLOWING ELEMENTS WERE ADDED TO ALIGN WITH CURRENT INVESTIGATION REQUIREMENTS: COMPLAINT INVESTIGATION RESULTS: ELECTRONIC QUALITY MANAGEMENT SYSTEM (EQMS) SEARCH: A QUERY WAS RUN IN THE EQMS ON 05/MAR/2026 AGAINST "LOT NUMBER" "6001974" AND SIMILAR MALFUNCTION CODES: LEAK BETWEEN TUBING AND SITE CONNECTOR - DETACHMENT / SIGNIFICANT WETNESS, LEAKAGE FROM CONNECTION BETWEEN THE TUBING CONNECTOR AND THE INFUSION SET (CANNULA PART/BASE PIECE), TUBING DETACHED FROM TUBING-TUBING CONNECTOR, TUBING CONNECTOR IS CRACKED, SPLIT, DEFORMED, LEAKAGE MAY OCCUR. THE REVIEW CONFIRMED THAT LOT 6001974 WAS ASSOCIATED WITH NC 1697002 FOR REMAINING LABEL 10X ON QUICK SET PRODUCT. HOWEVER, THIS NONCONFORMANCE IS NOT RELATED TO THE REPORTED FAILURE MODE AND IS NOT ASSOCIATED WITH ANY NON-CONFORMANCE (NC) OR CAPAS OF THE SAME OR SIMILAR NATURE. SIMILAR COMPLAINTS SEARCH: A QUERY WAS RUN IN THE EQMS ON 05/MAR/2026 AGAINST "LOT NUMBER" CRITERIA EQUAL "6001974" AND SIMILAR MALFUNCTION CODES: LEAK BETWEEN TUBING AND SITE CONNECTOR - DETACHMENT / SIGNIFICANT WETNESS, LEAKAGE FROM CONNECTION BETWEEN THE TUBING CONNECTOR AND THE INFUSION SET (CANNULA PART/BASE PIECE), IDD-PMC05.08 TUBING DETACHED FROM TUBING-TUBING CONNECTOR, TUBING CONNECTOR IS CRACKED, SPLIT, DEFORMED, LEAKAGE MAY OCCUR. THE NUMBER OF COMPLAINTS IS 1. THE COMPLAINT NUMBERS ARE COMPLAINT 1833935. DHR REVIEW: THE LOT 6001974 WAS MANUFACTURED ACCORDING TO WORK INSTRUCTION (WI) AND MANUFACTURED IN THE M12, ON 29/JUN/2023 WITH A TOTAL OF (B)(4) UNITS. THE SUB-ASSEMBLY: ASSEMBLY LOT 3F04122 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND ASSEMBLED IN THE QUICKSET LINE, ON 29-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3F04123 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND ASSEMBLED IN THE QUICKSET LINE, ON 29-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3F04124 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND ASSEMBLED IN THE QUICKSET LINE, ON 29-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. THE SUB-ASSEMBLY: TUBING GLUING LOT 3F03640 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND MANUFACTURED IN THE MACHINE MP05, ON 24-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3F04708 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND MANUFACTURED IN THE MACHINE MP05, ON 27-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3F03637 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND MANUFACTURED IN THE MACHINE MP08, ON 28-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3F04136 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND MANUFACTURED IN THE MACHINE MP05, ON 27-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3F04132 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) AND MANUFACTURED IN THE MACHINE MP08, ON 29-JUN-2023, WITH A TOTAL OF (B)(4) UNITS. REVIEW OF THE DHR SHOWED THAT DURING THE OUTGOING TEST AN NC 1697002 WAS FOUND FOR REMAINING LABEL 10X ON QUICK SET PRODUCT IN 16,700 PIECES IN THE LOT NUMBER #6001974 AND THEREFORE THE DHR SHOWED THAT ALL RELEVANT TESTS REQUIRED DURING THE RELATED PROCESSES HAD BEEN FULFILLED AND MET THE REQUIREMENTS. NO DEVIATIONS WERE IDENTIFIED, AND NO MAINTENANCE EVENTS WERE RECORDED THAT RELATE TO THE COMPLAINT CODE. CONCLUSION: DHR REVIEW SUPPORTS COMPLIANCE WITH MANUFACTURING AND QUALITY REQUIREMENTS; NO ISSUES NOTED. VISUAL EVIDENCE REVIEW: NO PHOTO WAS PROVIDED TO SUPPORT VISUAL CONFIRMATION OF THE REPORTED ISSUE. CONCLUSION: UNABLE TO PERFORM VISUAL VERIFICATION; ASSESSMENT BASED ON AVAILABLE DOCUMENTATION ONLY. CAPA DETERMINATION ASSESSMENT - CONCLUSION SUMMARY OF COMPLAINT INVESTIGATION: BASED ON THE INVESTIGATION, NO FURTHER INVESTIGATION IS REQUIRED. THE RECORD WILL BE CLOSED AND MONITORED THROUGH TRACKING AND TRENDING PER WORK INSTRUCTION (WI) (MONTHLY TRIPS AND ALERTS). THE INVESTIGATION FOR THIS COMPLAINT WAS PREVIOUSLY COMPLETED ON 26-FEB 2024 UNDER CHILD COMPLAINT INVESTIGATION RECORD (B)(4). THE INVESTIGATION HAS BEEN REVISED TO REFLECT THE UPDATED MALFUNCTION CODE AND NEW REPORTABILITY REQUIREMENTS. THE ORIGINAL INVESTIGATION REMAINS VALID AND HAS NOT BEEN MODIFIED. AS PART OF THIS REASSESSMENT, AN UPDATED EQMS SEARCH WAS PERFORMED WHICH IDENTIFIED ONE RELATED COMPLAINTS FOR LOT 6001974. NO NON-CONFORMANCE REPORT, CAPAS, TRENDS, OR SYSTEMIC ISSUES WERE FOUND. AS REQUIRED UNDER THE UPDATED REPORTABILITY CRITERIA, A FULL DEVICE HISTORY RECORD (DHR) REVIEW WAS CONDUCTED. ALL IN PROCESS AND FINAL INSPECTIONS MET SPECIFICATION REQUIREMENTS, AND NO DEVIATIONS, REWORK ACTIVITIES, OR MAINTENANCE EVENTS ASSOCIATED WITH THE MALFUNCTION WERE IDENTIFIED. NO VISUAL EVIDENCE WAS AVAILABLE TO SUPPORT CONFIRMATION OF THE REPORTED ISSUE. NO PHOTO EVIDENCE WAS PROVIDED, SO THE ASSESSMENT WAS BASED ON DOCUMENTATION ONLY. BASED ON THE EXPANDED INVESTIGATION INCLUDING UPDATED EQMS SEARCHES AND THE DHR REVIEW NO MANUFACTURING OR QUALITY ISSUES WERE IDENTIFIED. THE RECORD WILL BE CLOSED AND MONITORED THROUGH TRACKING AND TRENDING PER WORK INSTRUCTION (WI) (MONTHLY TRIPS AND ALERTS). COMPLAINT UNCONFIRMED: FOLLOWING INVESTIGATION, THE MALFUNCTION REMAINS UNCONFIRMED FOR THIS COMPLAINT.

Description of Event or Problem · 0

REFRENCE NUMBER (B)(4). EVENT OCCURRED IN URUGUAY. IT WAS REPORTED THAT THE PATIENT EXPERIENCED INFUSION SET TUBING DETACHED AT THE QUICK RELEASE DUE TO SWIMMING ON (B)(6) 2024. THE INFUSION SET HAD BEEN IN USE FOR LESS THAN ONE DAY AT THE TIME OF THE EVENT. THE INFUSION SITE WAS AT THE LOWER BACK. NO FURTHER INFORMATION AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
776359 QUICK SET UNO QUICK-SET 60/6 SC1 MECA FPA UNOMEDICAL DEVICES S.A. DE C.V. MMT-399A 6001974 05705244017450

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown