FDA Adverse Event Malfunction Summary report: N

QUICK SET

MDR report key: 24701137 · Received March 26, 2026

Report

Report Number
3003442380-2026-99988
Event Type
Malfunction
Date Received
March 26, 2026
Date of Event
January 13, 2024
Report Date
February 25, 2026
Manufacturer
UNOMEDICAL UM-D
Product Code
FPA
UDI-DI
05705244017450
PMA / PMN Number
K160648
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

E1: PATIENT CITY: (B)(6) PATIENT COUNTRY: POLAND. UNOMEDICAL HEREBY SUBMITS THIS INITIAL REPORT AS PART OF ITS COMPLAINT REMEDIATION ACTIVITIES CONDUCTED UNDER A CORRECTIVE AND PREVENTIVE ACTION (CAPA)/FDA ACTION PLAN. THIS SUBMISSION INCLUDES A RETROSPECTIVE REASSESSMENT OF PREVIOUSLY EVALUATED COMPLAINTS. UNOMEDICAL IS PROVIDING THIS INITIAL INFORMATION IN ACCORDANCE WITH THE REPORTING REQUIREMENTS SET FORTH IN 21 CFR PART 803. ANY FIELDS LEFT BLANK INDICATE THAT THE INFORMATION IS UNKNOWN, UNAVAILABLE, OR REMAINS UNCHANGED BASED ON THE REVIEW COMPLETED ON 25-FEB-2026 AND INVESTIGATION COMPLETED ON 12-MARCH-2026 THIS MEDICAL DEVICE REPORT (MDR) IS BEING SUBMITTED AS THE INITIAL REPORT. ADDITIONAL INFORMATION - THIS MDR IS BEING SUBMITTED TO INCLUDE THE BELOW: H6: INVESTIGATION RESULTS UNDER TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS. H11: INVESTIGATION SUMMARY. THE REFERENCE SAMPLES WERE VISUALLY INSPECTED AND TESTED FOR FLOW AND LEAK. ALL TEST RESULTS WERE WITHIN SPECIFICATIONS. THE BATCH RECORD #6001136 WAS VERIFIED AND IT WAS FOUND WITHIN SPECIFICATIONS. COMPLAINT INVESTIGATION RESULTS: ELECTRONIC QUALITY MANAGEMENT SYSTEM (EQMS) SEARCH: A QUERY WAS RUN IN THE EQMS ON 12/MAR/2026 AGAINST LOT NUMBER 6001136 AND SIMILAR MALFUNCTION CODES: LEAKAGE FROM INFUSION SITE (SPECIFIC CAUSE NOT IDENTIFIED), INSERTION SITE EGRESS A TRACE MOISTURE / SUPERFICIAL WETNESS THE REVIEW CONFIRMED THAT LOT 6001136 AND THE IDENTIFIED FAILURE MODE ARE NOT ASSOCIATED WITH ANY NON CONFORMANCE REPORT (NCRS) OR CORRECTIVE AND PREVENTIVE ACTION (CAPA) PLAN OF THE SAME OR SIMILAR NATURE. SIMILAR COMPLAINTS SEARCH: A QUERY WAS RUN IN THE EQMS ON 12/MAR/2026 AGAINST LOT NUMBER CRITERIA EQUAL 6001136 AND SIMILAR MALFUNCTION CODES: LEAKAGE FROM INFUSION SITE (SPECIFIC CAUSE NOT IDENTIFIED), INSERTION SITE EGRESS A TRACE MOISTURE / SUPERFICIAL WETNESS THE NUMBER OF COMPLAINT IS 1. THE COMPLAINT NUMBER IS COMPLAINT (B)(4). DEVICE HISTORY RECORD (DHR) REVIEW: THE LOT 6001136 WAS MANUFACTURED ACCORDING TO WORK INSTRUCTION (WI) VERSION 75 AND MANUFACTURED IN THE M08 LINE ON 25/APR/2023 WITH A TOTAL OF (B)(4) UNITS. THE SUB-ASSEMBLY: ASSEMBLY LOT 3D01878 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) VERSION 26 AND ASSEMBLED IN THE QUICKSET LINE, ON 22-APR-2023, WITH A TOTAL OF (B)(4) UNITS. LOT 3D01879 WAS MANUFACTURED ACCORDING TO THEWORK INSTRUCTION (WI) VERSION 26 AND ASSEMBLED IN THE QUICKSET LINE, ON 23-APR-2023, WITH A TOTAL OF (B)(4) UNITS. THE DEVICE HISTORY RECORD (DHR) WAS REVIEWED IN ACCORDANCE WITH APPLICABLE PROCEDURES. ALL REQUIRED IN-PROCESS AND FINAL TESTS WERE COMPLETED AND MET SPECIFIED REQUIREMENTS. NO DEVIATIONS WERE IDENTIFIED, AND NO MAINTENANCE EVENTS WERE RECORDED THAT RELATE TO THE COMPLAINT CODE. CONCLUSION: DHR REVIEW SUPPORTS COMPLIANCE WITH MANUFACTURING AND QUALITY REQUIREMENTS; NO ISSUES NOTED. VISUAL EVIDENCE REVIEW: NO PHOTO WAS PROVIDED TO SUPPORT VISUAL CONFIRMATION OF THE REPORTED ISSUE. CONCLUSION: UNABLE TO PERFORM VISUAL VERIFICATION; ASSESSMENT BASED ON AVAILABLE DOCUMENTATION ONLY. CAPA DETERMINATION ASSESSMENT - CONCLUSION SUMMARY OF COMPLAINT INVESTIGATION: BASED ON THE INVESTIGATION, NO FURTHER INVESTIGATION IS REQUIRED. THE RECORD WILL BE CLOSED AND MONITORED THROUGH TRACKING AND TRENDING PER WORK INSTRUCTION (WI) (MONTHLY TRIPS AND ALERTS). THE INVESTIGATION FOR THIS COMPLAINT WAS PREVIOUSLY COMPLETED ON 16-JAN-2024 UNDER CHILD COMPLAINT INVESTIGATION RECORD (B)(4). THE INVESTIGATION HAS BEEN REVISED TO REFLECT THE UPDATED MALFUNCTION CODE AND NEW REPORTABILITY REQUIREMENTS. THE ORIGINAL INVESTIGATION REMAINS VALID AND HAS NOT BEEN MODIFIED. AS PART OF THIS REASSESSMENT, AN UPDATED EQMS SEARCH WAS PERFORMED WHICH IDENTIFIED ONE RELATED COMPLAINT FOR LOT 6001136. NO NCRS, CAPAS, TRENDS, OR SYSTEMIC ISSUES WERE FOUND. AS REQUIRED UNDER THE UPDATED REPORTABILITY CRITERIA, A FULL DEVICE HISTORY RECORD (DHR) REVIEW WAS CONDUCTED. ALL IN PROCESS AND FINAL INSPECTIONS MET SPECIFICATION REQUIREMENTS, AND NO DEVIATIONS, REWORK ACTIVITIES, OR MAINTENANCE EVENTS ASSOCIATED WITH THE MALFUNCTION WERE IDENTIFIED. NO VISUAL EVIDENCE WAS AVAILABLE TO SUPPORT CONFIRMATION OF THE REPORTED ISSUE. NO PHOTO EVIDENCE WAS PROVIDED, SO THE ASSESSMENT WAS BASED ON DOCUMENTATION ONLY. BASED ON THE EXPANDED INVESTIGATION INCLUDING UPDATED EQMS SEARCHES AND THE DHR REVIEW NO MANUFACTURING OR QUALITY ISSUES WERE IDENTIFIED. THE RECORD WILL BE CLOSED AND MONITORED THROUGH TRACKING AND TRENDING PER WORK INSTRUCTION (WI) (MONTHLY TRIPS AND ALERTS)

Description of Event or Problem · 0

REFERENCE NUMBER (B)(4) EVENT OCCURRED IN POLAND. IT WAS REPORTED THAT PATIENT FACED INFUSION SET LEAKAGE EVENT AT THE SITE ON (B)(6) 2024. THE INFUSION SET WAS IN USE FOR ONE DAY. NO FURTHER INFORMATION IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
765323 QUICK SET UNO QUICK-SET 60/6 SC1 MECA FPA UNOMEDICAL UM-D MMT-399A 6001136 05705244017450

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown