FDA Adverse Event Malfunction Summary report: N

DAVINCI 5

MDR report key: 24691616 · Received March 25, 2026

Report

Report Number
2955842-2026-17926
Event Type
Malfunction
Date Received
March 25, 2026
Date of Event
February 28, 2025
Report Date
March 25, 2026
Manufacturer
INTUITIVE SURGICAL, INC
Product Code
NAY
UDI-DI
00886874119662
PMA / PMN Number
K232610
Removal / Correction Number
N/A
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NJ, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

AN INVESTIGATION WAS COMPLETED TO DETERMINE THE CAUSE OF THIS REPORTED EVENT. AN INTUITIVE SURGICAL, INC. (ISI) FIELD SERVICE ENGINEER (FSE) WAS DISPATCHED TO THE CUSTOMER SITE TO FURTHER INVESTIGATE THE REPORTED EVENT. FSE REPLACED PARTS TO RESOLVE ISSUE. THE SYSTEM WAS TESTED AND VERIFIED AS READY FOR USE. ISI DID RECEIVE A DA VINCI PRODUCT INVOLVED WITH THIS COMPLAINT TO PERFORM FAILURE ANALYSIS (FA). THE COMMON COMPUTE CONTROLLER (CCC) WAS ANALYZED THE CCC WAS VISUALLY INSPECTED, WHERE NO ISSUES WERE FOUND. UNIT WAS INSTALLED ON THE KNOWN GOOD IN-HOUSE SYSTEM AND THE VISION SIDE CART (VSC) MONITOR COULD NOT SHOW FULL DISPLAY ON THE SCREEN. THE VSC TOUCHSCREEN SHOWED "INSUFFLATOR DISABLED" MESSAGE. VSC POWER BUTTON KEPT FLASHING BLUE AND SYSTEM WOULD NOT COMPLETE FULL POWER UP SEQUENCE. THE UNIT WAS TAKEN TO A PROGRAMMING STATION WHERE IT WAS CONFIRMED TO BE BRICKED. THE COMPLAINT WAS CONFIRMED BASED ON FAILURE ANALYSIS, WHICH INDICATES THAT THE DEVICE MAY HAVE CONTRIBUTED TO THE CUSTOMER REPORTED ISSUE. THE ROOT CAUSE WAS DETERMINED TO BE A BRICKED CCC.

Description of Event or Problem · 0

IT WAS REPORTED THAT PRIOR TO STARTING A DA VINCI ASSISTED SURGICAL PROCEDURE, THE ROBOTICS COORDINATOR CONTACTED THE TECHNICAL SUPPORT ENGINEER (TSE) AND REPORTED THAT THE SYSTEM WON'T POWER ON ALL THE WAY. THE LIVE LOGS WEREN'T AVAILABLE AT THE TIME OF THE CALL. THE TSE ASKED WHAT THE POWER BUTTON WERE LOOKING LIKE. THE PATIENT CART AND CONSOLE HAVE SOLID BLUE AND VISION CART KEEPS BLINKING BLUE. AFTER HARD POWER CYCLE OF VISION CART POWER BUTTONS ARE THE SAME. THE TSE HAD THE CUSTOMER DISCONNECT BLUE FIBER CABLES FOR CONSOLE AND ROBOT STILL POWER BUTTON FLASHES ON TOWER AND SAYS INSUFFLATOR DISABLED. THE TSE HAD THE CUSTOMER POWER ON THE CONSOLE AND ROBOT BY ITSELF AND BOTH POWERED UP GOOD. THE CUSTOMER IS TRYING TO FIND ANOTHER SYSTEM TO USE FOR THE CASE. THE PROCEDURE WAS ABORTED TO ANOTHER DV SYSTEM.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
269110 DAVINCI 5 VISION SIDE CART NAY INTUITIVE SURGICAL, INC 380746-45 N/A 00886874119662

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown DA VINCI INSTRUMENTS AND ACCESSORIES