SPECTRA WAVEWRITER?
Report
- Report Number
- 3006630150-2026-01242
- Event Type
- Injury
- Date Received
- March 4, 2026
- Date of Event
- January 1, 2025
- Report Date
- May 9, 2026
- Manufacturer
- BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
- Product Code
- LGW
- UDI-DI
- 08714729951254
- PMA / PMN Number
- P030017
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- WA, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
BLOCK B3: EXACT DATE APPROXIMATED, EVENT OCCURRED IN (B)(6) 2025. ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED IN THE EVENT: PRODUCT FAMILY: SCS-LINEAR LEADS. UPN: M365SC2317500. MODEL: SC-2317-50. SERIAL: (B)(6). BATCH: (B)(6). UDI: (B)(4). PRODUCT FAMILY: SCS-LINEAR LEADS. UPN: M365SC2317500. MODEL: SC-2317-50. SERIAL: (B)(6). BATCH: (B)(6). UDI: (B)(4). INVESTIGATION RESULTS: ALL EXPLANTED DEVICES WERE NOT RETURNED FOR ANALYSIS; THEREFORE, A TECHNICAL ANALYSIS COULD NOT BE PERFORMED. DEVICE HISTORY RECORD: IT WAS CONFIRMED THAT ALL DEVICES MET MANUFACTURING SPECIFICATION PRIOR TO DISTRIBUTION AND THERE WERE NO MANUFACTURING DEVIATIONS WHICH COULD HAVE CONTRIBUTED TO THE REPORTED EVENT. LABELING REVIEW: REVIEW OF THE INSTRUCTIONS FOR USE (IFU) CONFIRMED THERE WAS RELEVANT CONTENT AND SUFFICIENT GUIDANCE WITH RESPECT TO THE CIRCUMSTANCES DESCRIBED WITHIN THIS COMPLAINT. NO UPDATES ARE REQUIRED TO THE IFU AS A RESULT OF THIS EVENT. INVESTIGATION CONCLUSION: ALL EXPLANTED DEVICES WERE NOT RETURNED FOR ANALYSIS AND THE COMPLAINT AS REPORTED COULD NOT BE CONFIRMED. RECORD REVIEW REVEALED NO ADDITIONAL INFORMATION RELATED TO THE COMPLAINT. THEREFORE, THIS INVESTIGATION IS UNABLE TO DETERMINE A PROBABLE CAUSE FOR THE COMPLAINT AND THE CONCLUSION CODE CAUSE NOT ESTABLISHED WILL BE USED.
BLOCK B3: EXACT DATE APPROXIMATED, EVENT OCCURRED IN JANUARY 2025. ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED IN THE EVENT: PRODUCT FAMILY: SCS-LINEAR LEADS. UPN: M365SC2317500. MODEL: SC-2317-50. SERIAL: (B)(6). BATCH: 5091214 / 7071926. UDI: (B)(4). PRODUCT FAMILY: SCS-LINEAR LEADS. UPN: M365SC2317500. MODEL: SC-2317-50. SERIAL: (B)(6) BATCH: 7071926 UDI: (B)(4).
IT WAS REPORTED THAT THE PATIENT'S IMPLANTABLE PULSE GENERATOR (IPG) WAS CAUSING PAIN. THE PATIENT UNDERWENT A PROCEDURE WHEREIN THE IPG AND LEADS WERE EXPLANTED AND THAT THE PATIENT WAS DOING WELL POSTOPERATIVELY. THE EXPLANTED DEVICES WERE RETAINED BY THE MEDICAL FACILITY AND WILL NOT BE RETURNED.
IT WAS REPORTED THAT THE PATIENT'S IMPLANTABLE PULSE GENERATOR (IPG) WAS CAUSING PAIN. THE PATIENT UNDERWENT A PROCEDURE WHEREIN THE IPG AND LEADS WERE EXPLANTED AND THAT THE PATIENT WAS DOING WELL POSTOPERATIVELY. THE EXPLANTED DEVICES WERE RETAINED BY THE MEDICAL FACILITY AND WILL NOT BE RETURNED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 449926 | SPECTRA WAVEWRITER? | STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF | LGW | BOSTON SCIENTIFIC NEUROMODULATION CORPORATION | SC-1160 | 359719 | 08714729951254 |