FDA Adverse Event Injury Summary report: N

WAVEWRITER ALPHA?

MDR report key: 24364637 · Received February 17, 2026

Report

Report Number
3006630150-2026-00933
Event Type
Injury
Date Received
February 17, 2026
Date of Event
January 14, 2025
Report Date
April 13, 2026
Manufacturer
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
Product Code
LGW
UDI-DI
08714729985099
PMA / PMN Number
P030017
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
TX, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION RESULTS: ALL EXPLANTED DEVICES WERE NOT RETURNED FOR ANALYSIS; THEREFORE, A TECHNICAL ANALYSIS COULD NOT BE PERFORMED. DEVICE HISTORY RECORD: IT WAS CONFIRMED THAT ALL DEVICES MET MANUFACTURING SPECIFICATION PRIOR TO DISTRIBUTION AND THERE WERE NO MANUFACTURING DEVIATIONS WHICH COULD HAVE CONTRIBUTED TO THE REPORTED EVENT. LABELING REVIEW: REVIEW OF THE INSTRUCTIONS FOR USE (IFU) CONFIRMED THERE WAS RELEVANT CONTENT AND SUFFICIENT GUIDANCE WITH RESPECT TO THE CIRCUMSTANCES DESCRIBED WITHIN THIS COMPLAINT. NO UPDATES ARE REQUIRED TO THE IFU AS A RESULT OF THIS EVENT. INVESTIGATION CONCLUSION: ALL EXPLANTED DEVICES WERE NOT RETURNED FOR ANALYSIS AND THE COMPLAINT AS REPORTED COULD NOT BE CONFIRMED. RECORD REVIEW REVEALED NO ADDITIONAL INFORMATION RELATED TO THE COMPLAINT. THEREFORE, THIS INVESTIGATION IS UNABLE TO DETERMINE A PROBABLE CAUSE FOR THE COMPLAINT AND THE CONCLUSION CODE KNOWN INHERENT RISK OF DEVICE WILL BE USED.

Additional Manufacturer Narrative · 0

ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENTS INVOLVED IN THE EVENT: PRODUCT FAMILY: SCS-LINEAR LEADS. UPN: M365SC2318700. MODEL: SC-2318-70. SERIAL: (B)(6). BATCH: 5002395. UDI: (B)(4). PRODUCT FAMILY: SCS-LINEAR LEADS. UPN: M365SC2318700. MODEL: SC-2318-70. SERIAL: (B)(6). BATCH: 5002322. UDI: (B)(4).

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING INADEQUATE STIMULATION DESPITE PROGRAM OPTIMIZATION. THE PATIENT UNDERWENT A PROCEDURE WHEREIN THE IMPLANTABLE PULSE GENERATOR (IPG) AND SPINAL CORD STIMULATOR (SCS) LEADS WERE EXPLANTED AND THAT THE PATIENT WAS DOING WELL POSTOPERATIVELY. THE EXPLANTED DEVICES WERE RETAINED BY THE MEDICAL FACILITY AND WILL NOT BE RETURNED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING INADEQUATE STIMULATION DESPITE PROGRAM OPTIMIZATION. THE PATIENT UNDERWENT A PROCEDURE WHEREIN THE IMPLANTABLE PULSE GENERATOR (IPG) AND SPINAL CORD STIMULATOR (SCS) LEADS WERE EXPLANTED AND THAT THE PATIENT WAS DOING WELL POSTOPERATIVELY. THE EXPLANTED DEVICES WERE RETAINED BY THE MEDICAL FACILITY AND WILL NOT BE RETURNED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
107379 WAVEWRITER ALPHA? STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF LGW BOSTON SCIENTIFIC NEUROMODULATION CORPORATION SC-1232 773069 08714729985099

Patients

Seq Age Sex Outcome Treatment
1 67 YR Male Required Intervention