BD BBL¿ GRAM SAFRANIN
Report
- Report Number
- 1119779-2026-00024
- Event Type
- Malfunction
- Date Received
- January 23, 2026
- Date of Event
- January 7, 2026
- Report Date
- March 3, 2026
- Manufacturer
- BECTON DICKINSON & CO. (SPARKS)
- Product Code
- JTS
- UDI-DI
- 30382902125311
- PMA / PMN Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SN
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
A DEVICE EVALUATION IS ANTICIPATED BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.
INVESTIGATION SUMMARY - THIS MEMO IS TO SUMMARIZE FINDINGS ON YOUR COMPLAINT RELATED TO BOTTLE GRAM SAFRANIN 250ML, CATALOG NUMBER 212531, BATCH NUMBER 4242097, COMPLAINT # (B)(4), FOR UNSATISFACTORY PERFORMANCE. COMPONENTS ARE MIXED AND DISPENSED INTO THE APPROPRIATE CONTAINERS. AFTER QC TESTING PRODUCT IS RELEASED AND TRANSPORTED TO THE DISTRIBUTION CENTER. THE COMPLAINT INVESTIGATION INCLUDED A BATCH HISTORY REVIEW OF GRAM CRYSTAL VIOLET. THE BATCH HISTORY RECORD REVIEW INDICATED NO DISCREPANCIES. ALL RELEASE TESTING WAS SATISFACTORY. COMPLAINT TRENDS WERE REVIEWED FOR A PERIOD COVERING 12 MONTHS. DURING THAT TIME THERE HAVE BEEN NO CONFIRMED COMPLAINTS FOR THE DEFECT IN QUESTION FOR THIS PRODUCT. ONE PHOTO WAS RECEIVED. THE PHOTO DEPICTS A MICROSCOPIC VIEW OF GRAM-NEGATIVE CULTURE AND TWO DARK PURPLE NONBACTERIAL ARTIFACTS. RETURN WAS RECEIVED ON 02/26/26 AFTER TESTING WAS COMPLETED. PACKAGE WAS RECEIVED DAMAGED AND SPILLED WITH MIXED MATERIALS. CONTENT INSIDE NOW MIXED MATERIALS AND CAN BE CONTAMINATED. NO FURTHER TESTING CAN BE CONDUCTED THIS TIME A RETENTION SAMPLE FROM THE COMPLAINT BATCH OF GRAM SAFRANIN WAS EVALUATED ALONG WITH A CONTROL BATCH. STAINING WAS COMPLETED PER INSTRUCTIONS IN THE PRODUCT INSERT. SLIDES OF E. COLI ATCC 25922 AND S. AUREUS ATCC 25923 CONTROLS WERE EVALUATED AND HAD SATISFACTORY STAINING RESULTS FOR THE RETENTION AND CONTROL BATCHES. THE RETENTION SAMPLE WAS COMPARABLE TO THE CONTROL. THIS COMPLAINT CANNOT BE CONFIRMED. WATERS WILL CONTINUE TO TREND DCM COMPLAINTS FOR UNSATISFACTORY PERFORMANCE.
IT WAS REPORTED WHILE USING ONE (1) BD BBL¿ GRAM SAFRANIN, THERE WERE ARTIFACTS VISIBLE IN THE SLIDE, RENDERING THE STAIN UNUSABLE. USER REPORTS THE APPEARANCE OF THE ARTIFACTS APPEARED SIMILAR TO GRAM POSITIVE COCCI. THERE WAS NO HEALTH IMPACT OR CONSEQUENCE REPORTED.
IT WAS REPORTED WHILE USING ONE (1) BD BBL¿ GRAM SAFRANIN, THERE WERE ARTIFACTS VISIBLE IN THE SLIDE, RENDERING THE STAIN UNUSABLE. USER REPORTS THE APPEARANCE OF THE ARTIFACTS APPEARED SIMILAR TO GRAM POSITIVE COCCI. THERE WAS NO HEALTH IMPACT OR CONSEQUENCE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 233585 | BD BBL¿ GRAM SAFRANIN | STAINS, MICROBIOLOGIC | JTS | BECTON DICKINSON & CO. (SPARKS) | 4242097 | 30382902125311 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |