FDA Adverse Event Injury Summary report: N

ETHILON NYLON SUTURE UNKNOWN PRODUCT

MDR report key: 24078546 · Received January 15, 2026

Report

Report Number
2210968-2026-00538
Event Type
Injury
Date Received
January 15, 2026
Date of Event
January 1, 2024
Report Date
January 15, 2026
Manufacturer
ETHICON INC.
Product Code
GAR
PMA / PMN Number
NA
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. THERE ARE NO CONTACT DETAILS GIVEN WITHIN THIS EVENT AND THEREFORE NO FOLLOW UP WILL BE PERFORMED. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. H6 COMPONENT CODE: G07002 ¿ DEVICE NOT RETURNED D4: UDI: AS THE CATALOG/MODEL NUMBER WAS NOT PROVIDED, THE (01) GTIN IS NOT AVAILABLE. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. CITATION: INTERNATIONAL JOURNAL OF PHARMACEUTICAL AND CLINICAL RESEARCH 2024; 16(4); 243-249 PLEASE SEE ARTICLE ATTACHED.

Description of Event or Problem · 0

PROSPECTIVE STUDY TO EVALUATE THE FUNCTIONAL OUTCOME IN PATIENTS WITH DISTAL TIBIA FRACTURES UNDERGOING LOCKING COMPRESSION PLATE FIXATION USING MINIMAL INVASIVE ¿MIPPO¿ TECHNIQUE. THE AIM OF THE STUDY THE FUNCTIONAL OUTCOME OF DISTAL TIBIA FRACTURES IN PATIENTS TREATED BY MINIMAL INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS (MIPPO) TECHNIQUE WITH DISTAL TIBIA LOCKING COMPRESSION PLATE. THIS STUDY HAD A PROSPECTIVE CLINICAL STUDY DESIGN CONDUCTED AT GOVT. R. D. B. P. JAIPURIA HOSPITAL ATTACHED WITH RUHS COLLEGE OF MEDICAL SCIENCES, JAIPUR, RAJASTHAN. TOTAL OF 30 PATIENTS WITH CLOSED, OPEN FRACTURE TYPE 1 (GUSTILO AND ANDERSON CLASSIFICATION) FRACTURE OF DISTAL TIBIA WITH OR WITHOUT INTRA ARTICULAR EXTENSION WERE INCLUDED IN THE STUDY. WOUND CLOSURE WAS PERFORMED BY USING SUBCUTANEOUS VICRYL AND ETHILON 2-0 SKIN SUTURE TO CLOSE THE INCISION SITE. REPORTED COMPLICATIONS INCLUDE: VICRYL (ETHICON) ETHILON (ETHICON) INFECTION (N=3) TREATMENT: NOT REPORTED IN CONCLUSION, THE PRESENT STUDY CONCLUDES THAT MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS (MIPPO) USING LCP IS A SAFER MODALITY FOR TREATING DISTAL TIBIAL FRACTURES WITHOUT SIGNIFICANT INTRA-ARTICULAR COMMINUTION BECAUSE IT PROMOTES RAPID FUNCTIONAL RECOVERY, GOOD FRACTURE HEALING, AND PREVENTS SERIOUS SKIN PROBLEMS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
139928 ETHILON NYLON SUTURE UNKNOWN PRODUCT SUTURE, NONABSORBABLE GAR ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Other