WAVEWRITER ALPHA? 16
Report
- Report Number
- 3006630150-2026-00071
- Event Type
- Injury
- Date Received
- January 5, 2026
- Date of Event
- November 17, 2025
- Report Date
- March 25, 2026
- Manufacturer
- BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
- Product Code
- LGW
- UDI-DI
- 08714729985082
- PMA / PMN Number
- P030017
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- ND, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
MODEL NUMBER/CATALOG NUMBER: SC-1216/ SC-2408-56/ SC-4319 SERIAL NUMBER: (B)(6) BATCH/LOT NUMBER: 791383/ 7088243/ 7089177/ 36765814. INVESTIGATION RESULTS THE DEVICE WAS NOT RETURNED FOR ANALYSIS; THEREFORE, A TECHNICAL ANALYSIS COULD NOT BE PERFORMED. (GOOD FAITH EFFORT ATTEMPTS WERE MADE TO TRY AND RETRIEVE THE DEVICE; HOWEVER RESPONSE WAS NOT RECEIVED.) DEVICE HISTORY RECORD IT WAS CONFIRMED THIS DEVICE MET MANUFACTURING SPECIFICATION PRIOR TO DISTRIBUTION AND THERE WERE NO MANUFACTURING DEVIATIONS WHICH COULD HAVE CONTRIBUTED TO THE REPORTED EVENT. LABELING REVIEW OF THE INSTRUCTIONS FOR USE (IFU) CONFIRMED THERE WAS RELEVANT CONTENT AND SUFFICIENT GUIDANCE WITH RESPECT TO THE CIRCUMSTANCES DESCRIBED WITHIN THIS COMPLAINT. NO UPDATES ARE REQUIRED TO THE IFU AS A RESULT OF THIS EVENT. INVESTIGATION CONCLUSION BASED ON A THOROUGH REVIEW OF THE REPORTED COMPLAINT, BOSTON SCIENTIFIC HAS ASSIGNED AN INVESTIGATION CONCLUSION CODE OF KNOWN INHERENT RISK OF DEVICE.
ADDITIONAL SUSPECT MEDICAL DEVICE COMPONENT INVOLVED IN THE EVENT: PRODUCT FAMILY: SCS-LINEAR LEADS-MRI. UPN: M365SC2408560. MODEL: SC-2408-56. SERIAL: (B)(6). BATCH: (B)(6). UDI: (B)(4). PRODUCT FAMILY: SCS-LINEAR LEADS-MRI. UPN: M365SC2408560. MODEL: SC-2408-56. SERIAL: (B)(6). BATCH: (B)(6). UDI: (B)(4). PRODUCT FAMILY: SCS-LEAD FIXATION-MRI. UPN: M365SC43190. MODEL: SC-4319. BATCH: 36765814. UDI: (B)(4).
IT WAS REPORTED THAT THE PATIENT DEVELOPED AN INFECTION IN WHICH CAUSED ITCHINESS AND FLUID DISCHARGE AT THE POCKET AND LEAD SITE. THE PATIENT WAS PROVIDED WITH ANTIBIOTICS. IT WAS ALSO NOTED THAT IN THE PHYSICIANS OPINION THE INFECTION WAS NEITHER DEVICE NOR PROCEDURE RELATED. THE PATIENT UNDERWENT A SPINAL CORD STIMULATOR (SCS) EXPLANT PROCEDURE , WAS DOING WELL POSTOPERATIVELY AND THE EXPLANTED DEVICES WERE DISPOSED BY THE FACILITY.
IT WAS REPORTED THAT THE PATIENT DEVELOPED AN INFECTION IN WHICH CAUSED ITCHINESS AND FLUID DISCHARGE AT THE POCKET AND LEAD SITE. THE PATIENT WAS PROVIDED WITH ANTIBIOTICS. IT WAS ALSO NOTED THAT IN THE PHYSICIANS OPINION THE INFECTION WAS NEITHER DEVICE NOR PROCEDURE RELATED. THE PATIENT UNDERWENT A SPINAL CORD STIMULATOR (SCS) EXPLANT PROCEDURE , WAS DOING WELL POSTOPERATIVELY AND THE EXPLANTED DEVICES WERE DISPOSED BY THE FACILITY. CULTURE WAS TAKEN BUT NO INFORMATION WAS DIVULGED AS TO THE RESULT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 23479 | WAVEWRITER ALPHA? 16 | STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF | LGW | BOSTON SCIENTIFIC NEUROMODULATION CORPORATION | SC-1216 | 791383 | 08714729985082 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 73 YR | Male | Required Intervention |