FDA Adverse Event Malfunction Summary report: N

OMNIPOD 5 AUTOMATED INSULIN DELIVERY SYSTEM

MDR report key: 23895218 · Received December 26, 2025

Report

Report Number
3004464228-2025-64258
Event Type
Malfunction
Date Received
December 26, 2025
Date of Event
December 2, 2025
Report Date
December 29, 2025
Manufacturer
INSULET CORPORATION
Product Code
QFG
UDI-DI
10385083000138
PMA / PMN Number
K203768
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

ACCORDING TO THE COMPLAINANT THE DEVICE WILL NOT BE RETURNED FOR INVESTIGATION. LOT RELEASE RECORDS WERE REVIEWED, AND THE PRODUCT LOT MET ALL ACCEPTANCE CRITERIA. WE ARE UNABLE TO CONFIRM OR DETERMINE THE ROOT CAUSE OF THE REPORTED DISLODGED CANNULA. CLOUD - LOCKED DOWN/SMARTPHONE DATA NOT AVAILABLE. CLOUD - OMNIPOD 5 SOFTWARE APP VERSION DATA NOT AVAILABLE. CLOUD - SMARTPHONE OPERATING SYSTEM DATA NOT AVAILABLE. CLOUD - SMARTPHONE HARDWARE DATA NOT AVAILABLE. CLOUD - CGM SENSOR TYPE DATA NOT AVAILABLE. PLEASE NOTE, THE DEVICE IDENTIFIERS ARE CAPTURED AS REPORTED BY THE COMPLAINANT AND MAY NOT ALIGN WITH THE DEVICE CONFIGURATION REPORTED IN THIS SECTION AS THIS DATA IS PULLED FROM OUR CLOUD BASED ON THE REPORTED DATE OF EVENT.

Additional Manufacturer Narrative · 0

UPDATED H1 ADDITIONAL MFR NARRATIVE. FROM; ACCORDING TO THE COMPLAINANT THE DEVICE WILL NOT BE RETURNED FOR INVESTIGATION. LOT RELEASE RECORDS WERE REVIEWED, AND THE PRODUCT LOT MET ALL ACCEPTANCE CRITERIA. WE ARE UNABLE TO CONFIRM OR DETERMINE THE ROOT CAUSE OF THE REPORTED DISLODGED CANNULA. LOCKED DOWN SMARTPHONE: LOCKDOWN. OMNIPOD SOFTWARE APP VERSION: 3.1.5-P001. OPERATING SYSTEM: N5004L-AM-Q-MV01602-06-01.06. HARDWARE: N5004L. CGM SENSOR TYPE: G7. PLEASE NOTE, THE DEVICE IDENTIFIERS ARE CAPTURED AS REPORTED BY THE COMPLAINANT AND MAY NOT ALIGN WITH THE DEVICE CONFIGURATION REPORTED IN THIS SECTION AS THIS DATA IS PULLED FROM OUR CLOUD BASED ON THE REPORTED DATE OF EVENT. TO; ACCORDING TO THE COMPLAINANT THE DEVICE WILL NOT BE RETURNED FOR INVESTIGATION. NO LOT RELEASE RECORDS WERE REVIEWED, AS THE PRODUCT LOT NUMBER WAS NOT PROVIDED. WE ARE UNABLE TO CONFIRM OR DETERMINE THE ROOT CAUSE OF THE REPORTED DISLODGED CANNULA. LOCKED DOWN SMARTPHONE: LOCKDOWN. OMNIPOD SOFTWARE APP VERSION: 3.1.5-P001. OPERATING SYSTEM: N5004L-AM-Q-MV01602-06-01.06. HARDWARE: N5004L. CGM SENSOR TYPE: G7. PLEASE NOTE, THE DEVICE IDENTIFIERS ARE CAPTURED AS REPORTED BY THE COMPLAINANT AND MAY NOT ALIGN WITH THE DEVICE CONFIGURATION REPORTED IN THIS SECTION AS THIS DATA IS PULLED FROM OUR CLOUD BASED ON THE REPORTED DATE OF EVENT.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT'S BLOOD GLUCOSE LEVEL ROSE TO "USUALLY HIGHER THAN" 23.0MMOL/L (414 MG/DL) WHILE WEARING THE POD. THE POD REPORTEDLY FELL OFF THE INFUSION SITE, CAUSING THE CANNULA TO DISLODGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2403801 OMNIPOD 5 AUTOMATED INSULIN DELIVERY SYSTEM ALTERNATE CONTROLLER ENABLED INSULIN INFUSION PUMP QFG INSULET CORPORATION PT-000438 10385083000138

Patients

Seq Age Sex Outcome Treatment
1 12 YR Male