C6 SENSOR 3.0
Report
- Report Number
- 2133409-2025-00153
- Event Type
- Death
- Date Received
- November 13, 2025
- Report Date
- November 13, 2025
- Manufacturer
- BRAEMAR MANUFACTURING, LLC
- Product Code
- DSI
- PMA / PMN Number
- K153473
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IL, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THE EVENTS TRANSMITTED ON (B)(6) 2025 (DATE OF LAST MSA ACTIVITY) WERE REVIEWED BY THE CLINICAL OPERATIONS AND MEDICAL SAFETY. PER MSA, POST-TAVR NOTIFICATION CRITERIA WERE ASSOCIATED WITH THE PATIENT STUDY. A REVIEW OF MSA ACTIVITY CONFIRMED 8 TRIGGERED EVENTS THAT MET CRITERIA FOR URGENT/ EMERGENT CRITERIA OCCURRED ON (B)(6) 2025 BETWEEN 0217 AND 0805 EST. THE NOTIFICATIONS INCLUDED: EMERGENT -ACCELERATED IDIOVENTRICULAR RHYTHM WITH TORSADES DE POINTES, EMERGENT -JUNCTIONAL RHYTHM WITH PAC(S) AND TORSADES DE POINTES, EMERGENT -TORSADES DE POINTES WITH MULTIPLE PAUSES NOTED, LONGEST PAUSE IS 8.6SECONDS, EMERGENT -VENTRICULAR FIBRILLATION WITH 9.4 SECOND PAUSE, VENTRICULAR FIBRILLATION WITH MULTIPLE PAUSES NOTED, LONGEST PAUSE IS 3.6SECONDS, URGENT - VENTRICULAR FIBRILLATION WITH MULTIPLE PAUSES NOTED, LONGEST PAUSE IS 3.6SECONDS, EMERGENT -VENTRICULAR FIBRILLATION WITH 1ST DEGREE AVB IVCD AND MULTIPLE PAUSES NOTED, LONGEST PAUSE IS 3.6 SECOND, EMERGENT -VENTRICULAR FIBRILLATION WITH MULTIPLE PAUSES NOTED, LONGEST PAUSE IS 8.1 SECONDS, AND URGENT - ATRIAL FLUTTER WITH IVCD SINUS BEATS AND MULTIPLE PAUSES NOTED, LONGEST PAUSE IS 3.6 SECONDS. THE EVENTS WERE TRANSMITTED TO MSA ON (B)(6) 2025 0911 - 0947 EST AND THEN ADJUDICATED AND NOTIFIED PER SOP ON (B)(6) 2025. DATE OF DEATH AND TIME OF DEATH IS CURRENTLY NOT CONFIRMED. BASED ON THE AVAILABLE INFORMATION, THERE WAS A DELAY IN TRANSMISSION OF CARDIAC EVENTS MEETING URGENT/ EMERGENT NOTIFICATION CRITERIA. THERE IS INSUFFICIENT INFORMATION TO DETERMINE THE IMPACT OF THE DELAY. THE CAUSE OF THE DELAYED TRANSMISSION CANNOT BE DETERMINED BY CLINICAL REVIEW.
AFTER REVIEWING THE PATIENT'S FILE, IT WAS NOTED THAT THE PATIENT BEGAN SERVICE ON (B)(6) 2025 WITH THE MCOT SERVICE - UNSPECIFIED SUBSYSTEM / SUBCOMPONENT AND WAS SCHEDULED TO END SERVICE ON (B)(6) 2025. MSA ACTIVITY STARTED ON (B)(6) 2025. ON (B)(6) 2025 WITHIN THE MSA ACTIVITY LOG, THERE WERE MULTIPLE EMERGENT AND URGENT ESCALATION NOTIFICATIONS DOCUMENTED. IT WAS NOTED ON (B)(6) 2025 THE MEDICAL CENTER RECEIVED MULTIPLE EMERGENT EVENTS FOR THIS PATIENT THAT WERE RECEIVED LATE FROM THE MONITOR. MEDICAL CENTER NURSE EXPRESSED CONCERN THAT THESE EVENTS WERE OVER 30 HOURS LATE. TECHNICIAN EXPLAINED THAT WE RECEIVED THEM TODAY FROM THE MONITOR AND WE DO NOT HAVE INSIGHT ON WHY THIS OCCURRED, WANTED TO GIVE A HEADS UP ON THIS ISSUE AS THE EVENTS WERE SEVERE. EVENT TIMES RANGE FROM (B)(6) 2025 (2:17) EDT TO 6:57 EDT. THE EVENTS STARTED COMING ON (B)(6) 2025 (9:11) EDT. FIRST CALL TO PRACTICE (B)(6) 2025 AT (10:09) EDT, NO ONE AVAILABLE TO TAKE CALL PER SERVICE REPRESENTATIVE WHO STATED "WILL SEND A MESSAGE TO CALL US BACK. SECOND CALL (11:32) EDT WAS TOLD SOMEONE WILL CALL US BACK, THIRD CALL (12:13) EDT LEFT MESSAGE WITH ADMINISTRATIVE ASSISTANT. IT WAS DOCUMENTED THAT THE PATIENT DIED ON (B)(6) 2025. THE PRACTICE COMPLAINED ABOUT DELAYED TRANSMISSION TIME AND VERBAL NOTIFICATION. IT WAS NOTED THAT THE REASON WHY THE NOTIFICATION FROM(B)(6) 2025 WERE DELAYED IN VERBALLY NOTIFYING, IS BECAUSE THE DEVICE DID NOT TRANSMIT THE ECG (ELECTROCARDIOGRAM) DATA OVER TO US UNTIL (B)(6) 2025, APPROXIMATELY 30 HOURS LATER, HENCE THE DELAY IN VERBALLY NOTIFYING THE PRACTICE. WE DO NOT KNOW DEVICE WAS DELAYED IN TRANSMITTING OVER THE ECG STRIPS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2206613 | C6 SENSOR 3.0 | MCOT SENSOR - 3.0 | DSI | BRAEMAR MANUFACTURING, LLC | 02-01846 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 76 YR | Male | Death | MCOT MONITOR - A10E - VERIZON-UNLOCKED(B)(6). |