FDA Adverse Event Injury Summary report: N

ARCTIC FRONT ADVANCE PRO¿ CARDIAC CRYOABLATION CATHETER

MDR report key: 23535163 · Received November 12, 2025

Report

Report Number
3002648230-2025-01125
Event Type
Injury
Date Received
November 12, 2025
Date of Event
August 4, 2025
Report Date
November 12, 2025
Manufacturer
MEDTRONIC CRYOCATH LP
Product Code
OAE
PMA / PMN Number
P100010
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
HU
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

CONTINUATION FROM D10: PRODUCT ID: 2AF283. PRODUCT TYPE: BALLOON CATHETER; PRODUCT ID: 4FC12 PRODUCT TYPE: SHEATH; PRODUCT ID: 990063-020. PRODUCT TYPE: MAPPING CATHETER THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. MEDTRONIC WAS MADE AWARE OF THIS EVENT THROUGH A SEARCH OF LITERATURE PUBL ICATIONS. THIS EVENT OCCURRED OUTSIDE THE US. PATIENT INFORMATION IS LIMITED DUE TO CONFIDENTIALITY CONCERNS. OF NOTE, MULTIPLE PATIENTS AND MULTIPLE MANUFACTURERS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE-TO-ONE CORRELATION COULD NOT BE MADE WITH UNIQUE PRODUCT SERIAL/LOT NUMBERS. THE BASELINE GENDER/AGE CHARACTERISTICS IS MALE/65 YEARS OLD. THE MODEL LISTED IN THE REPORT IS A REPRESENTATIVE OF THE MODEL FAMILY, AS THERE IS NO SPECIFIC MODEL LISTED. WITHOUT A LOT NUMBER OR DEVICE SERIAL NUMBER, THE MANUFACTURING DATE, EXPIRATION DATE, AND UDI CANNOT BE DETERMINED. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. A REQUEST FOR ADDITIONAL INFORMATION WAS MADE. IF ADDITIONAL INFORMATION IS OBTAINED REGARDING THIS EVENT, IT WILL BE ADDED, AND A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY. REFERENCED ARTICLE: ASSESSING THE VALUE OF ROUTINE PREPROCEDURAL CT ANGIOGRAPHY IN CRYOBALLOON PULMONARY VEIN ISOLATION: A PROSPECTIVE, PROPENSITY SCORE¿MATCHED STUDY. IJC HEART VASCULATURE. 2025. 60: 101769 DOI: DOI.ORG/10.1016/J.IJCHA.2025.101769. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.

Description of Event or Problem · 0

LITERATURE WAS REVIEWED REGARDING ASSESSING THE VALUE OF ROUTINE PREPROCEDURAL CT ANGIOGRAPHY IN CRYOBALLOON PULMONARY VEIN ISOLATION. THE AUTHORS DESCRIBED THERE WERE PATIENTS WHO EXPERIENCED AN ACCESS SITE HEMATOMA AND PHRENIC NERVE PARESIS. THE STATUS OF THE DEVICES IS UNKNOWN. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2503056 ARCTIC FRONT ADVANCE PRO¿ CARDIAC CRYOABLATION CATHETER CATHETER, PERCUTANEOUS, CARDIAC ABLATION, FOR TREATMENT OF ATRIAL FIBRILLATION OAE MEDTRONIC CRYOCATH LP AFAPRO28

Patients

Seq Age Sex Outcome Treatment
1 65 YR Male Other