FDA Adverse Event Malfunction Summary report: N

OCTARAY MAPPING CATHETER

MDR report key: 23472244 · Received November 4, 2025

Report

Report Number
2029046-2025-03712
Event Type
Malfunction
Date Received
November 4, 2025
Date of Event
October 13, 2025
Manufacturer
BIOSENSE WEBSTER INC
Product Code
MTD
UDI-DI
10846835021141
PMA / PMN Number
K193237
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) ABLATION PROCEDURE WITH AN OCTARAY MAPPING CATHETER AND IT WAS NOT IRRIGATING PROPERLY. DEVICE EVALUATION DETAILS: THE DEVICE WAS RETURNED TO JOHNSON & JOHNSON MEDTECH (J&J MEDTECH) FOR EVALUATION. FOLLOWING J&J MEDTECH PROCEDURES, A VISUAL INSPECTION AND IRRIGATION TEST OF THE RETURNED DEVICE WERE PERFORMED. VISUAL INSPECTION REVEALED NO DAMAGE OR ANOMALIES ON THE DEVICE. AN IRRIGATION TEST WAS PERFORMED, AND THE CATHETER FAILED THE TEST DUE TO THE IRRIGATION TUBE WAS FOUND FOLDED AT THE TIP AREA. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE BATCH NUMBER, AND NO INTERNAL ACTIONS WERE IDENTIFIED. THE IRRIGATION ISSUE REPORTED BY THE CUSTOMER WAS CONFIRMED. THE POTENTIAL CAUSE OF THE IRRIGATION TUBE FOLDED COULD NOT BE DETERMINED. THE CATHETER INSTRUCTIONS FOR USE (IFU) CONTAIN THE FOLLOWING RECOMMENDATIONS: FLUSH THE CATHETER WITH HEPARINIZED NORMAL SALINE PRIOR TO INSERTION INTO THE BODY AND ENSURE THAT SALINE FLOWS THROUGH THE DISTAL END OF THE IRRIGATION LUMEN. AS PART OF JOHNSON & JOHNSON MEDTECH'S QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. MANUFACTURER'S REF. # (B)(4).

Additional Manufacturer Narrative · 0

ON (B)(6) 2025, THE BWI PRODUCT ANALYSIS LAB RECEIVED THE COMPLAINT DEVICE FOR EVALUATION. THE PRODUCT ANALYSIS HAS BEGUN BUT IS NOT COMPLETED AT THIS TIME. WHEN THE INVESTIGATIONAL ANALYSIS HAS BEEN COMPLETED, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY BIOSENSE WEBSTER INC., OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, BIOSENSE WEBSTER INC., OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. MANUFACTURER'S REF. #(B)(4).

Description of Event or Problem · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) ABLATION PROCEDURE WITH AN OCTARAY MAPPING CATHETER AND IT WAS NOT IRRIGATING PROPERLY. IT WAS REPORTED THAT WHEN THE CATHETER ABOUT TO BE REINSERTED INTO THE BODY, THE PHYSICIAN NOTICED THAT THE CATHETER WAS NOT IRRIGATING PROPERLY. CALLER STATED THEY OPENED THE PRESSURE LINE WITHOUT RESOLUTION. THEY TRIED MANUALLY FLUSHING THE CATHETER WITHOUT RESOLUTION. WHEN THE CATHETER WAS REPLACED, THE ISSUE RESOLVED. THE CATHETER WAS BRAND NEW AND NOT REPROCESSED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2492144 OCTARAY MAPPING CATHETER CATHETER, INTRACARDIAC MAPPING, HIGH-DENSITY ARRAY MTD BIOSENSE WEBSTER INC 31736732L 10846835021141

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown FARAPULSE SYSTEM.| UNKNOWN IRRIGATION SYSTEM.