FDA Adverse Event Injury Summary report: N

INSPIRA SMOOTH SILICONE GEL FILLED BREAST IMPLANT

MDR report key: 23311129 · Received October 16, 2025

Report

Report Number
9617229-2025-17698
Event Type
Injury
Date Received
October 16, 2025
Date of Event
June 18, 2025
Report Date
December 5, 2025
Manufacturer
ALLERGAN (COSTA RICA)
Product Code
FTR
PMA / PMN Number
P020056
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL, CHANGED, AND/OR CORRECTED DATA: B5, B6, D.6B, D9, H3, H6.

Additional Manufacturer Narrative · 0

CONTINUED E1: ALTERNATE EMAIL ADDRESS: (B)(6). A REVIEW OF THE DEVICE HISTORY RECORD HAS BEEN COMPLETED. NO DEVIATIONS OR NON-CONFORMANCES NOTED. THE EVENT OF CAPSULAR CONTRACTURE IS A PHYSIOLOGICAL COMPLICATION AND ANALYSIS OF THE DEVICE GENERALLY DOES NOT ASSIST ALLERGAN IN DETERMINING A PROBABLE CAUSE FOR THIS EVENT. FURTHER INFORMATION FROM THE REPORTER REGARDING EVENT, PRODUCT, OR PATIENT DETAILS HAS BEEN/WILL BE REQUESTED. NO ADDITIONAL INFORMATION IS AVAILABLE AT THIS TIME. REASON FOR REOPERATION: CAPSULAR CONTRACTURE, BAKER GRADE III.

Additional Manufacturer Narrative · 0

DEVICE EVALUATION: THE DEVICE RELATED TO THE REPORTED EVENT OF CAPSULAR CONTRACTURE WAS RECEIVED ON OCTOBER 29, 2025, WITH LOT NUMBER 1191393. PER THE INVESTIGATION PROCEDURE, THE DEVICE IS ANALYZED THROUGH VISUAL INSPECTION MICROSCOPIC INSPECTION IF OPENINGS ARE OBSERVED AND A WEIGHT VERIFICATION. PER THE ANALYSIS PERFORMED, THE ASSESSMENTS OF THE COMPLAINTS AND ANY POTENTIAL MANUFACTURING ISSUE ARE DISPLAYED ALONG WITH ANY FURTHER ACTIONS REQUIRED: ¿ CAPSULAR CONTRACTURE: UNABLE TO OBSERVE THROUGH VISUAL INSPECTION AS IT IS A PHYSIOLOGICAL PHENOMENON. NONE OF THE OTHER OBSERVATIONS PERFORMED DURING THE DEVICE ANALYSIS (CREASES AND DEFORMATION) ARE FOUND TO BE POTENTIALLY RELATED TO THE MANUFACTURING PROCESS, AND, THEREFORE, NO FURTHER ACTIONS ARE REQUIRED FOR THESE OBSERVATIONS.

Description of Event or Problem · 0

HEALTHCARE PROFESSIONAL REPORTED "CAPSULAR CONTRACTURE BAKER GRADE III". LATER, HEALTHCARE PROFESSIONAL REPORTED "1 CM MASS", "ASYMMETRY" AND "CYST IDENTIFIED" WITH "BENIGN APPEARANCE". THIS RECORD IS FOR THE LEFT SIDE. THE DEVICE HAS BEEN EXPLANTED AND REPLACED. CAPSULECTOMY WAS ALSO DONE.

Description of Event or Problem · 0

HEALTHCARE PROFESSIONAL REPORTED "CAPSULAR CONTRACTURE BAKER GRADE III". THIS RECORD IS FOR THE LEFT SIDE. THE DEVICE REMAINS IMPLANTED. EXPLANT SURGERY IS SCHEDULED AND THE DEVICE WILL BE RETURNED.

Description of Event or Problem · 0

HEALTHCARE PROFESSIONAL REPORTED "CAPSULAR CONTRACTURE BAKER GRADE III". LATER, HEALTHCARE PROFESSIONAL REPORTED "1 CM MASS", "ASYMMETRY" AND "CYST IDENTIFIED" WITH "BENIGN APPEARANCE". THIS RECORD IS FOR THE LEFT SIDE. THE DEVICE WAS EXPLANTED. REPLACED AND HAS BEEN RETURNED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2694348 INSPIRA SMOOTH SILICONE GEL FILLED BREAST IMPLANT PROSTHESIS, BREAST, NONINFLATABLE, INTERNAL, SILICONE GEL-FILLED FTR ALLERGAN (COSTA RICA) 1191393

Patients

Seq Age Sex Outcome Treatment
1 40 YR Female Required Intervention